Laserfiche WebLink
• <br />• <br />Memorandum <br />Dated August 9, 2002 <br />Page 2 <br />No sanitary sewer lengths were provided. <br />No lift station information was provided. <br />No force main information provided. <br />Sanitary sewer must be SDR 26 or 35 pipe. <br />Angles of pipes entering manholes must be provide for appropriate flow. <br />Trunk Lines may be required. <br />Utility extension to Carl Street will be reviewed. <br />Sanitary sewer stubs at the subdivision boundaries must be extended for future <br />connection. <br />Street Standards: <br />No profile provided. <br />No street layout dimensioning provided. <br />No street cross - section provided. <br />It appears the streets do not all meet a 30 -mph design. <br />No connection is shown to Carl Street. <br />An alternate street is shown for the proposed hanger area. <br />Phasing of the plan shows dead end street lengths in excess of City standards <br />with no circulation of traffic until all phases have been completed. <br />No proposed layout showing future street connections was provided. <br />A traffic study dated August 5, 2002, and received on August 7, 2002, is currently <br />under review. <br />Storm Sewer: <br />No storm sewer information was provided. <br />Grading Standards: <br />Review will be performed upon receiving the necessary information as outlined above. <br />Recommendation: <br />No recommendation can be given at this time due to the insufficient amount of design <br />information provided. <br />