Laserfiche WebLink
• <br />Century Farm North <br />Page 5 of 11 <br />• Lots 1 and 13, Block 2 have been found to measure only 95 feet in width. As corner lots, <br />their width should be increased to 100 feet as required within R -1 zoning districts. <br />• In review of the grading and drainage plan, there appears to be substantial topography <br />upon Lot 12, Block 2 which may limit its buildability. As a result, it is recommended <br />that the applicant demonstrate its buildability via the submission of a custom plan. <br />• Considering that Carl Street/Century Trail is expected to be a high volume roadway, it is <br />believed the impact of such roadway upon Lots 3 and 4, Block 2 (at the intersection of <br />Sunset Road and Century Trail) could be lessened by providing interior access to such <br />lots from the northeast via the "L" shaped cul -de -sac. In conjunction with such <br />modification, screening could be provided in the rear yard areas at the Sunset /Century <br />Trail intersection (see attached development plan alternative). <br />• The home and driveway upon Lot 20, Block 2 should be re- oriented toward the cul -de <br />sac. <br />• One final concern relates to Lots 6 and 7, Block 6 (as depicted on the preliminary site <br />plan) where it appears the side lot line between the two lots was inadvertently not shown. <br />In regard to Lot 7, Block 6 specifically, it is recommended that the driveway of such lot <br />be oriented to the west rather than the south (to eliminate driveway maneuvering at what <br />is expected to be a busy intersection and not to isolate the home from neighboring <br />dwellings). <br />Airpark Lots. As shown on the submitted development plans, the subject site borders the Lino <br />Airpark and includes 15 "airpark" lots. To accommodate such lots, the processing of a PDO is <br />necessary. Considering that the Comprehensive Plan identifies the airpark as a long -term use <br />within the City and that non - inhabitable structures over the gas line are preferred, the inclusion <br />of such lots is considered generally acceptable. In regard to such lots however, some concerns <br />do exist as summarized below: <br />• The locations of Lots 4 and 9, Block 4. Of primary concern is the location of an airpark <br />lot (Lot 4. Block 4) between two "traditional" single family lots and the adjacency of <br />Lots 5 -8, Block 4 to the airpark taxiway and hanger building. To address this concern, it <br />is suggested that Lot 4 be converted from an "airpark" to "traditional" single family lot <br />and that Lot 9 be eliminated combined with the lots to the north to create a buffer yard. <br />• The impact of runway safety zone extensions upon area lots. As a condition of PUD <br />approval, the applicant should provide documentation to the City that all applicable <br />runway safety zone requirements have or will be satisfied. <br />