Laserfiche WebLink
• Mueller Site Plan <br />March 12, 2003 <br />page 2 <br />The submittal complies with the CB zoning standards as follows: <br />MUSA: The site currently is not within the MUSA. With the adoption of the <br />comprehensive plan, the City has a MUSA reserve. As stated in the comprehensive plan <br />and reiterated in Ordinance 01 -03, the Growth Management Policy, we have a total of 74 <br />acres of commercial/industrial MUSA reserve. This can be allocated anytime prior to <br />year 2010. The Mueller project will require .73 acres of MUSA reserve. <br />Building: The building resembles a rambler, and thus will be compatible with the <br />residential character of the James St. neighborhood. The footprint is approximately 5766 <br />sf. The building will be approximately 20 ft. high (average height of the pitched roof, <br />according to the definition in the zoning ordinance). The exterior walls of the building <br />will have a cultured stone base with face brick above. The roof will be asphalt shingles. <br />The trash area is shown on the plan and will be screened with a wall of the same face <br />brick as on the building. <br />Parking <br />For offices, our code requires three spaces minimum, plus one space per 200 sf. For the <br />purposes of calculating parking spaces, the ordinance requirement is to use 90% of the <br />gross building area. <br />gross <br />Required <br />Proposed <br />Lot size minimum <br />none <br />0.8 acres <br />(existing) <br />Lot width minimum <br />none <br />Required <br />Setbacks: buildings <br />from street <br />rear lot line <br />side lot line <br />parking <br />from street <br />rear lot line <br />side lot line <br />40, 30 <br />10 <br />10 <br />15 <br />10 <br />10 <br />40, 30 <br />140 ± <br />10 <br />15 <br />10 <br />10 <br />Bldg. height <br />45 <br />20 ± <br />Green space <br />85% <br />53% <br />MUSA: The site currently is not within the MUSA. With the adoption of the <br />comprehensive plan, the City has a MUSA reserve. As stated in the comprehensive plan <br />and reiterated in Ordinance 01 -03, the Growth Management Policy, we have a total of 74 <br />acres of commercial/industrial MUSA reserve. This can be allocated anytime prior to <br />year 2010. The Mueller project will require .73 acres of MUSA reserve. <br />Building: The building resembles a rambler, and thus will be compatible with the <br />residential character of the James St. neighborhood. The footprint is approximately 5766 <br />sf. The building will be approximately 20 ft. high (average height of the pitched roof, <br />according to the definition in the zoning ordinance). The exterior walls of the building <br />will have a cultured stone base with face brick above. The roof will be asphalt shingles. <br />The trash area is shown on the plan and will be screened with a wall of the same face <br />brick as on the building. <br />Parking <br />For offices, our code requires three spaces minimum, plus one space per 200 sf. For the <br />purposes of calculating parking spaces, the ordinance requirement is to use 90% of the <br />gross building area. <br />gross <br />code <br />Spaces <br />Spaces <br />area <br />90% <br />requirement <br />Required <br />Provided <br />5766 <br />5189 <br />1 per 200, plus 3 <br />29 <br />31 <br />Lighting: Light fixtures in the parking lot will be on two poles. One, in a central <br />location, will have four fixtures. The other will be near the driveway. All parking lot <br />fixtures will be 90 degree cutoff fixtures. <br />