Laserfiche WebLink
4.4 <br />Mueller Site Plan <br />March 12, 2003 <br />page 4 <br />RECOMMENDATION <br />Staff recommends approval of the Site and Building Plans and MUSA Allocation with <br />the following conditions: <br />1. The trash screening enclosure will use the same brick as the principal building. <br />2. Lighting must meet ordinance requirements of no more than 0.4 foot candles at the <br />residential property line to the east, and no more than 1.0 at street centerlines. <br />3. The utility related modifications and comments as set forth in the City Engineer's <br />memo, dated March 6, 2003, shall be incorporated into the final plans. <br />4. The grading and drainage related modifications and comments as set forth in the City <br />Engineer's memo, dated March 6, 2003, shall be incorporated into the plans. <br />5. The grading and drainage plans shall be revised to include tree protection measures <br />and measures to avoid soil compaction in designated infiltration areas. <br />6. The Landscaping Plan shall be revised to include City native seed schedule for all <br />infiltration and ponding areas. <br />7. The applicant shall enter into a Site Performance Agreement with the City. Such <br />agreement shall provide for ongoing maintenance of ponding and infiltration areas. <br />ATTACHMENTS <br />1. General Location Map <br />2. Grading, Drainage and Erosion Control Plan <br />3. Site and Utility Plan <br />4. Landscaping and Tree Preservation Plan <br />5. Building Exterior Elevations <br />6. Environmental Board Comments <br />7. City Engineer's Comments <br />