Laserfiche WebLink
• <br />Marshan Townhomes 2"d Addn. <br />page 4 <br />Growth Management: The City's growth management policy (Ordinance 01 -03) <br />implements growth policies of the comprehensive plan. It establishes limits on the <br />number of new units to be approved as well on the use of MUSA reserve. The site is <br />within the existing MUSA, so the MUSA reserve limit is not applicable. The 147 units <br />per year have been reached for both 2003 and 2004. This project would exceed the goal <br />for 2004 by 45 %. This exceeds the 20% discretion provided by the policy. <br />PRELIMINARY PLAT/PLANNED UNIT DEVELOPMENT <br />Buildings, Units: <br />The proposal includes four buildings. The two northern buildings have 10 units each. <br />Another has 12 units, and the southern building has 14 units. This totals 46 units. All <br />units are two - story. Each building is double- loaded. <br />Building materials include vinyl siding, wood shakes in gable ends, and a stone base. <br />Under the current building and fire code, sprinklers are required for all structures of 8500 <br />sf or greater. This includes garage area. All proposed buildings would need sprinklers. <br />* The minimum open space for an urban PUD is 50 %. A memo from the applicant lists <br />the total site area as 176,362 sf, and the impervious area as 88,181 sf. This is exactly <br />50 %. If the project proceeds, this calculation should be re- checked. <br />required <br />proposed <br />base lot area <br />R -3: 24,000 sf <br />R -4: 20,000 sf <br />ample <br />base lot width <br />100 ft <br />100+ ft between access <br />drives <br />unit lot width <br />24 ft <br />32 ft <br />unit size <br />R -3: 920 sf <br />1400+ sf <br />setbacks <br />local street <br />arterial street <br />side yard <br />rear yard <br />30 ft <br />40 ft <br />R -3: 10 ft <br />R -4: 20 ft <br />30 <br />30 ft <br />40 ft <br />25 ft <br />-- <br />impervious <br />max. 65% <br />50% open <br />space for PUD <br />50 %* <br />height max. <br />R -3: 36 ft <br />R -4: 45 ft <br />? <br />The proposal includes four buildings. The two northern buildings have 10 units each. <br />Another has 12 units, and the southern building has 14 units. This totals 46 units. All <br />units are two - story. Each building is double- loaded. <br />Building materials include vinyl siding, wood shakes in gable ends, and a stone base. <br />Under the current building and fire code, sprinklers are required for all structures of 8500 <br />sf or greater. This includes garage area. All proposed buildings would need sprinklers. <br />* The minimum open space for an urban PUD is 50 %. A memo from the applicant lists <br />the total site area as 176,362 sf, and the impervious area as 88,181 sf. This is exactly <br />50 %. If the project proceeds, this calculation should be re- checked. <br />