Laserfiche WebLink
• <br />Mr. Michael Grochala <br />April 24, 2006 <br />Page 3 <br />10. The hydrant between Buildings 11 and 12 conflicts with a proposed light pole. <br />be moved to provide clear access to the hydrant. <br />11. Applicant shall provide locations of proposed sewer and water services in <br />Center Parkway, and Woods Edge Boulevard. <br />12. Sanitary manhole castings shall be Type R- 1642 -B. <br />One or the other must <br />Village Drive, Town <br />Preliminary Storm Sewer Plan (Sheet C4.1) <br />1. We recommend that CBMH 201 be moved northward so the storm sewer between CBMH 201 and <br />Woods Edge Boulevard is moved farther away from the northwest corner of Building 3. <br />STMH 104 must be moved so that the storm pipe from CBMH 109 to STMH 104 will maintain a 10- <br />foot separation with the water main, as required by the Minnesota Department of Health. <br />3. The southwestern corner of the courtyard for the southernmost unit in Building 9 is shown as being <br />constructed over the existing storm sewer. Either the courtyard should be revised so that no <br />construction occurs above the storm sewer pipe or the storm sewer line must be relocated. <br />4. No details or quantities for rip -rap are given for FES 400. <br />5. STMH 401 is too shallow. The apparent 2.37 -foot build height would be exceeded by the sum of <br />pipe diameter + wall thickness + top slab thickness + casting height. <br />6. The applicant should consider adding stubs at STMH 104 and CBMH 105 for future storm design <br />flexibility on the western half of the site. Resize downstream storm sewer accordingly if stubs are <br />provided. <br />7. The storm sewer connection from CBMH 301 cannot be made as shown. Connection to the existing <br />storm sewer shall be made by utilizing a new structure at the point of connection. <br />8. Storm sewer pipe classes must be shown. <br />Preliminary Lighting Plan (Sheet C4.2) <br />1. An additional light pole shall be installed on the south end of the drive aisle between Buildings 9 and <br />10. <br />Proposed light poles are 2 feet shorter than City street lights but this may be appropriate for interior <br />residential areas. <br />3. Lighting levels in the drive aisles and parking areas are not continuous but are appropriate for <br />residential uses. <br />Preliminary Landscape Plan (Sheet C5.0) <br />1. Applicant shall verify plantings around Pond 3 will not interfere with the required pond access road. <br />2. Planting trees on top of storm sewer, sanitary sewer, or water mains is not allowed. <br />3. Additional screening around the lift station site is recommended. <br />RECEDED <br />APR 2 5 2000 <br />C6TV OP UNO LAKES <br />