My WebLink
|
Help
|
About
|
Sign Out
Home
Search
06/14/2006 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2006
>
06/14/2006 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2014 11:46:35 AM
Creation date
6/23/2014 1:38:56 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
06/14/2006
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TKDA <br />• ENGINEERS • ARCHITECTS • PLANNERS <br />• <br />MEMORANDUM <br />1500 Piper Jaffray Plaza <br />444 Cedar Street <br />Saint Paul, MN 55101 -2140 <br />(651) 292-4400 <br />(651) 292-0083 Fax <br />www.tkda.com <br />To: James E. Studenski, P.E. Reference: The Preserve Development <br />City Engineer Site Review <br />Copies To: City of Lino Lakes, Minnesota <br />From: Thomas D. Prew, P.E. Proj. No.: 13604.009 <br />Date: June 2, 2006 Routing: <br />The following site review is based on these submittals: <br />1. Revised Site Development Plans, submitted by MFRA dated May 22, 2006. <br />2. Geotechnical Report submitted by Interstate Geotechnical Engineering, Inc. dated May 24, 2006. <br />Street and Trail Comments: <br />1. The radius for the temporary cul -de -sac and easement must be shown on the plans and curb and gutter <br />must be installed. <br />2. Standard bituminous mix specifications should reference Mn/DOT 2360 for trail. <br />3. A minimum 250' radius must be used for the connection to Kildeer Drive. <br />Sanitary Sewer and Watermain Comments: <br />1. Profiles must be provided to confirm crossing conflicts and adequate cover. <br />2. Details must be provided in conformance to City Standards. <br />3. Minimum separation from 3' x 6' box culvert of 3' must be labeled on plan and profile. <br />4. Indicate the size, type, and filling of the casing pipe to be installed. <br />5. Additional gate valve is required along Pheasant Run South of the 3' x 6' box culvert. <br />6. The watermain installed through the wetland area must be approved by the RCWD, and proposed <br />stabilization and installation process must be provided. <br />7. Each entire building pad must be covered by a 250' radius to a hydrant. Please refer to the letter from <br />Centennial Fire District dated April 18, 2006. <br />8. Remove incorrect "176 LF 8" SDR 35 PVC @ 0.4 %" note on the sanitary FM. The correct size and type <br />• should be labeled. <br />An Employee Owned Company Promoting Affirmative Action and Equal Opportunity <br />
The URL can be used to link to this page
Your browser does not support the video tag.