My WebLink
|
Help
|
About
|
Sign Out
Home
Search
03/09/2011 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2011
>
03/09/2011 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2014 10:17:28 AM
Creation date
6/24/2014 11:17:03 AM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
03/09/2011
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />• <br />• The circulation of vehicles around the gas pumps is an issue. A previous sketch <br />demonstrated conflict with the parking stalls on the front of the main building, <br />and the layout in the submittal has not changed. An option may be shifting <br />canopy and pumps slightly to the east to allow more room to exit the pump <br />islands. Alternatively, the three pumps could be aligned in one line. It may be <br />necessary to eliminate one set of pumps. The circulation on the submitted plan is <br />problematic and should be redesigned. <br />b. Architectural Standards. <br />1) As a part of the conditional use permit application, a color illustration of all building <br />elevations shall be submitted. <br />2) The architectural appearance, scale, and functional plan of the building(s) and <br />canopy shall be complementary and compatible with each other and the existing <br />buildings in the neighborhood setting. <br />3) All sides of the principal and accessory structures are to have essentially the same or <br />a coordinated harmonious finish treatment pursuant to Section 3, Subd. 4. B of this <br />Ordinance. <br />4) Exterior wall treatments like brick, stone (natural or artificial), decorative concrete <br />block and stucco shall be used. <br />5) Earth tone colors of exterior materials including the canopy columns shall be <br />required. "Earth tone colors" shall be defined as any various soft colors like those <br />found in nature in soil, vegetation, etc., such colors are limited to brown, black, gray, <br />tan, beige, brick red, soft green, soft blue, or white. <br />6) Ten (10) percent of the building facade may contain contrasting colors. Contrasting <br />colors shall be those colors not defined as earth tones. The canopy may have <br />contrasting color bands or accent lines not to exceed an accumulative width of four <br />(4) inches. The color bands shall not be illuminated. <br />• Section 3, Subd. 4.B establishes architectural standards for commercial <br />buildings, including building materials and colors. These are reiterated the <br />motor fuel station requirements, though canopies are a little different. See the <br />canopy discussion below. <br />c. Canopy. A protective canopy structure may be located over the pump island(s), as an <br />accessory structure. The canopy shall meet the following performance standards: <br />1) The edge of the canopy shall be thirty (30) feet or more from the front and /or side lot <br />line, provided that adequate visibility both on -site and off -site is maintained. <br />2) The canopy shall not exceed eighteen (18) feet in height and must provide fourteen <br />(14) feet of clearance to accommodate a semi - trailer truck passing underneath. <br />3) The canopy fascia shall not exceed three (3) feet in vertical height. <br />• The application meets these requirements. <br />4) Canopy lighting shall consist of canister spotlights recessed into the canopy. No <br />portion of the light source or fixture may extend below the ceiling of the canopy. <br />Total canopy illumination may not exceed one hundred fifteen (115) foot candles <br />below the canopy at ground level. <br />• We did not receive cut sheets of the proposed canopy lighting as required for <br />all site plans. This is an incomplete item. We need to ensure the fixtures are <br />recessed. The submitted photometric plan shows that canopy illumination <br />directly below the canopy meets the requirement. However, the photometric <br />plan does not extend beyond the canopy. There are requirements for the <br />
The URL can be used to link to this page
Your browser does not support the video tag.