My WebLink
|
Help
|
About
|
Sign Out
Home
Search
09/11/2001 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2001
>
09/11/2001 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2014 1:51:04 PM
Creation date
7/1/2014 10:27:28 AM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
09/11/2001
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />• <br />Molin Concrete <br />September 11, 2001 <br />page 14 <br />2. Final utility, grading, and drainage plans must obtain approval from the City Engineer <br />prior to site grading or building permit. This condition applies to the overall <br />conditional use permit for the concrete plant, covering the entire site, as well as the <br />site plan review for the new building. <br />3. If off - street parking creates safety concerns in the future, the City shall re- examine <br />the parking needs and may require additional parking spaces. This condition applies <br />to the overall conditional use permit for the concrete plant, covering the entire site. <br />4. Proper building permits must be obtained prior to any construction of the new <br />building. All proposed structures shall comply with applicable City building material <br />requirements. An escrow shall be established according to City policy as part of the <br />building permit to insure completion of all site improvements. This condition applies <br />to the site and building plan review. <br />5. The approval of the site plan and amended conditional use permit includes the 85± <br />foot height of the cement silos, as provided by Sec. 3. Subd 4.C.3. of the zoning <br />ordinance, which allows a building height to exceed the zoning district standard with <br />a conditional use permit. <br />6. The surfacing material of the site as shown on the submitted site plan and grading <br />plan is acceptable. Additional bituminous areas may be paved without additional <br />review by the City. This condition applies to the overall conditional use permit for <br />the concrete plant, covering the entire site. <br />7. Outdoor lighting is prohibited in the site's outdoor storage area (north of 77th <br />St./Thomas St.). Permissible exterior lighting on the southern portion of the property <br />shall be hooded and directed to reflect light away from neighboring residential <br />properties and rights -of -way. This condition applies to the overall conditional use <br />permit for the concrete plant, covering the entire site, as well as the interim use permit <br />on the northern portion. <br />8. A photometric lighting plan for the new building and structures shall be submitted to <br />ensure compliance with City lighting requirements. Cut sheets or photos of exterior <br />lighting fixtures shall be submitted. The photometric plan and cut sheets shall be <br />submitted and reviewed prior to City Council consideration of the applications. This <br />applies to the site plan review. <br />9. The site's western access point (from 4th Avenue) shall remain at the 77th St./Thomas <br />St. alignment. Access to Lilac St. shall be maintained as on the plans received by the <br />City August 13, 2001. This condition applies to the overall conditional use permit <br />for the concrete plant, covering the entire site, as well as the interim use permit on the <br />northern portion. <br />
The URL can be used to link to this page
Your browser does not support the video tag.