Laserfiche WebLink
Subdivision Application-Check List <br /> Development <br /> Compliance <br /> Yes No <br /> k. Topographic data, at time of survey, including <br /> contours at vertical intervals of not more than <br /> two (2) feet. Water courses, wetlands, rock <br /> outcrops, power transmission poles and lines, and <br /> other significant features shall also be know. <br /> 1. Proposed grading plans showing the proposed <br /> contours of the finished grading which shall <br /> occur prior to the installation of utilities with <br /> the legend clearly shown. <br /> m. Proposed plan for surface water disposal, <br /> ponding, drainage and flood control. <br /> n. In plats where public sewer is not <br /> available, the subdivider shall file a report <br /> prepared by a registered civil engineer or <br /> certified soil tester on the feasibility of <br /> individual on-site sewer and water systems on <br /> each lot, and shall include soils boring analysis <br /> and percolation tests to verify conclusions. <br /> o. Layouts of proposed streets showing the right-of- <br /> way widths, centerline gradients, typical cross <br /> sections, and proposed names of streets in <br /> conformance with City and County street <br /> identification policies. The name of any street <br /> heretofore used in the City or its environs shall <br /> not be used unless the proposed street is a <br /> logical extension of an already named street, in <br /> which event the same name shall be used. <br /> p. Locations and widths of proposed alleys and <br /> pedestrian ways. <br /> q. Location, dimension and purpose of all easements. <br /> r. Locations of proposed sewer lines and water <br /> mains. <br /> s. Layout, numbers, lot areas, and preliminary <br /> dimensions of lots and blocks. <br /> t. Table of lots and block indicating 1) square <br /> footage, 2) width at setback, 3) depth. <br /> u. Minimum front and side street building setback <br /> lines. <br /> v. When lots are located on a curve, the width <br /> of the lot at the building setback line. <br /> w. Water Supply. Water mains shall be provided <br /> to serve the subdivision by extension of an <br /> existing community system whenever feasible. <br /> Service connections shall be stubbed into the <br /> property line and all necessary fire hydrants <br /> shall also be provided. Extensions of the public <br /> water supply system shall be designed so as to <br /> provide public water in accordance with the <br /> standards of the City of Lino Lakes. In areas <br /> where public water supply is not available, <br /> 3 <br />