Laserfiche WebLink
C. Series 700 HydroFlon <br />1. Exterior Exposure - ASTM D 4141, Method C (EMMAQUA). <br />a. No blistering, cracking or chalking. No less than 80 percent gloss retention, no more than <br />10 units gloss loss and no more than 0.45 DEHunter color change after 3,500 MJ/m2 <br />EMMAQUA exposure (UV). <br />2. Cleanability - MIL -PRF -85285D Section 4.6.13. <br />a. No less than 95% cleaning efficiency. <br />3. Graffiti Resistance - acrylic spray paint, epoxy spray paint, Markette marker, ball point ink, <br />crayon, lipstick applied with 7 day cure. <br />a. Complete removal. <br />4. Abrasion — ASMT D 4060 (CS -17 Wheel, 1,000g Load). <br />a. No more than 110mg loss after 1,000 cycles. <br />PART 3 EXECUTION <br />3.01 PREPARATION OF SURFACE <br />A. Interior Wet Surface: The entire wet interior surface of the tank shall be cleaned of all paint, <br />grease, oil, rust, mill scale, and other foreign or loose material. Cleaning shall be done in <br />accordance with the Society for Protective Coatings Specification SSPC-SP-10, Near -White Blast <br />Cleaning with a minimum angular anchor profile of 2.0 mils. Before any primer or paint is applied, <br />metal surface shall be completely dry, dust free, inspected and approved by the Resident Project <br />Representative. All structural repairs must be completed prior to final surface preparation <br />procedures. <br />B. Exterior Surface: The entire exterior surfaces of the tank shall be cleaned of all paint, grease, oil, <br />rust, mill scale, and other foreign or loose materials before any primer or coating is applied. <br />Cleaning shall be done in accordance with the Society for Protective Coatings Specification SSPC- <br />SP-6, Commercial Blast Cleaning with a minimum angular anchor profile of 2.0 mils. Before any <br />primer or coating is applied, metal surfaces shall be completely dry, dust free, inspected, and <br />approved by the Resident Project Representative. All structural repairs must be completed prior to <br />final surface preparation. Full negative air containment will be required per Article 3.02. <br />C. Dry Interior Surface: The interior dry surfaces that are subjected to condensation of the tank shall <br />be cleaned of all paint, grease, oil, rust, mill scale, and other foreign or loose materials before any <br />primer or coating is applied. These areas include the drywell tube, the bowl, the top 2 feet of the <br />fluted support column, the top side of the condensate ceiling, the water piping in the tank and in <br />the valve pit, and any random coating failures as well as areas of structural modifications. For <br />bidding purposes, it is estimated that there are approximately 7,500 square feet of surface that will <br />require surface preparation and painting. Cleaning shall be done in accordance with the Society <br />for Protective Coatings Specification SSPC-SP-6, Commercial Blast Cleaning with a minimum <br />angular anchor profile of 2.0 mils. Interior dry surfaces of the tank blasted to a SSPC-SP-6, <br />Commercial Blast Cleaning shall be feathered into the existing paint system according to SSPC-SP- <br />3-82 Power Tool Cleaning. Before any primer or coating is applied, metal surfaces shall be <br />completely dry, dust free, inspected, and approved by the Resident Project Representative. All <br />structural repairs must be completed prior to final surface preparation. <br />3.02 EXTERIOR SANDBLAST CONTAINMENT <br />A. The Contractor shall be fully responsible to provide full containment as required of the exterior <br />tank abrasive blasting operation, including top bonnet or cover to prevent the drift of spent <br />abrasive and existing exterior paint removed onto adjacent property, streets, or structures. <br />WATER TOWER REPAINTING <br />© 2012 Stantec 1 193803415 09 91 55 - 4 <br />