2. Remove factory -applied coatings in the area to be soldered, from materials <br />such as alloy -coated copper or alloy -coated stainless steel. Use solvent <br />recommended by manufacturer. <br />3. Mechanically clean, flux, and smoothly pre -tin with solder edges of sheets <br />and other locations to be soldered. Tinning shall be thin, uniform in <br />thickness, and 1 1/2" wide on both sides of sheet at folded locked seam <br />locations. <br />4. Immediately prior to joining pieces to be soldered, mechanically clean <br />pre -tinned surfaces, wipe clean, dry, and fully coat with flux. Use least <br />corrosive flux suitable for given application. <br />5. Slide pieces together and neatly dress down with a block of wood and <br />mallet and/or dead -blow hammer <br />6. Perform soldering with heavy soldering coppers of blunt design, properly <br />prepared and tinned before using. They shall weigh not less than 10 lbs. <br />per pair, except when acetylene gas -heated soldering copper torch is used, <br />copper itself shall weigh not less than 1.25 lbs. Soldering with torch alone <br />is not acceptable. <br />7. Perform soldering slowly with well heated copper. Thoroughly heat <br />surfaces to be soldered. Use heated surfaces rather than the soldering <br />copper, to melt the solder and draw it into the seam. <br />8. Use ample solder. Seam shall show at least one full inch of evenly flowed <br />solder. <br />9. Whenever possible, solder in flat position. At sloped seams, start down- <br />slope and work up-slope. Solder seams a second time on slopes equal to <br />or greater than 45 degrees. <br />10. Neutralize and remove flux residue as recommended by the flux <br />manufacturer and the American Welding Society. This may include items <br />such as mechanical removal, hot acidified water wash, water and washing <br />soda (sodium carbonate) wash and clan water rinse after soldering. <br />C. Counterflashing at Wall and Curbs: <br />1. Counterflashing shall be designed and fabricated in minimum 96 -inch <br />lengths where job dimensions allow (lesser lengths at curbs). Skirt <br />member shall be of size indicated with bottom edge folded under 1/2 inch, <br />fabricated in such manner as to hold the bottom firmly against the <br />flashings, and formed to fit field conditions. Skirt members, when <br />installed, shall be securely fastened with gasketed screws and/or fasteners <br />as detailed. <br />2. Coping cover plates shall be 6 inches wide, and counterflashing shall have <br />S -slip end joints provided, as detailed, and be fabricated of same gauge <br />and material as flashing. Furnish complete with a continuous ribbon of <br />flashing sealant as shown on details. <br />Flashing and Sheet Metal <br />07 62 00-8 <br />City of Lino Lakes <br />Lino Lakes Fire Station #1 <br />RSI Project # 15-12120-02 <br />