T1 IE CITY OF <br />LA <br />beyond and is stacked shoulder high on the train floor preventing access to the <br />basement. Further inspection and evaluation was not possible. (See Exhibit 34 <br />Detached Garage <br />The detached garage located to the north of the house is dilapidated and structurally <br />unsafe to enter. The following observations were completed from the exterior and for <br />looking inside the service door located on the east side of the structure: <br />1. The bottom chord of the roof trusses are bowing and near breaking in several <br />locations, likely clue to the large amount of storage placed in the roof system; <br />Trusses are spaced 4' on center and are not designed for storage: gills and framing <br />near the bottom plates are rotted and structurally unsound. <br />High Voltage Electrical wiring and alien electrical boxesthroughoutthe building. <br />3. Siding is rotted and decayed. <br />4. boor and window openings are not flashed and rotted allowing weather inside the <br />structure further creating damage and rot to the framing structure. <br />5: (See Exhibits 56, 57, 58, 59, 60, 61, 62, 63,; 1, 2 <br />The above detailed and cited items are in violation of the fallowing sections of the City of <br />Lake Elmo Property Maintenance Code (Also known as the 2006 International Property <br />Maintenance Code; which. the City of Lake Amer adopted per City Code § 1 .3 5): <br />1. LEPMC 108.1.3 Structure unfit for human. occupancy. A structure is unfit for <br />human occupancy whenever the code official finds that such structure is unsafe, <br />unlawful or, because of the degree to which the structure is in disrepair or lacks <br />maintenance, is unsanitary, vermin or rat infested, contains filth and <br />contamination, or lacks ventilation, illumination, sanitary or heating facilities or <br />other essential equipment required by this code, or because the location of the <br />structure constitutes a hazard to the occupants of the structure or the public. <br />The property does not have water service, sewage dispersal, Beating facilities, a <br />working bathroom or kitchen sink and is structurally unsafe, is in disrepair, lacks <br />maintenance, is unsanitary and constitutes a hazard to the occupants. <br />2.. LEPMC 305 Interior Structure 305.1 General. The interior of a structure and <br />equipment therein shall be maintained in good repair, structurally sound and in a <br />sanitary condition. Occupants shall keep that part of the structure which they <br />occupy or control in a clean and sanitary condition, every owner of a structure <br />3800 Laverne Avenge North * take Elmo * Minnesota * 55042 * 651.7473900 <br />