My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
RESOLUTION 2017-066
LakeElmo
>
City Council
>
Resolutions (1970's to 2020)
>
2010's
>
2017
>
RESOLUTION 2017-066
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2025 11:51:06 AM
Creation date
2/4/2021 8:55:04 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LAKE <br />moon I <br />the wall and ceiling surface areas" High voltage electrical wiring is exposed in <br />multiple areas throughout the room. This room has a bed and as confirmed by the <br />property owner, this is the bedroom. There is no smoke alarm or carbon monoxide <br />detector present_ (See Exhibits 2, 2, 27, 28 2) <br />t. There is no identifiable bathroom facility or plumbing fixtures present in the <br />home. There is no kitchen sink nor any food preparation area in the home. <br />Homeowner stated she does not have running water nor is there a sewage system <br />connection present. The natural gas meter is strut off, homeowner stated she heats <br />with a portable electric heater:- <br />T The main floor beam that runs north and south in the center of the home and <br />supports the second floor framing is bowing in the center from excessive load. <br />Beam is showing signs of structural failure and requires verification of sizing; <br />additional support needed and verification of support through to the footings in <br />the basement. (See Exhibits 22, 23, a <br />The floor joists to the second floor are bowing uniformly from the front to back <br />due to excessive load. Multiple joist Have split and broken and have had sister 2 <br />4 framing added incorrectly along the side but have not been added full length and <br />add little additional support. The second floor system is unsafe and should be <br />evaluated by a structural engineer for the required additional structural support <br />needed. The same floor joists are rotted on the ends in multiple areas along the <br />east wall at the plate due to the lack of a weather tight exterior, (See Exhibits 21, <br />2 , 23, , 3, 46, 47, 0 <br />. Stair to the second floor area is loose and not secure. No handrails or guards are <br />present and top stair treads are broken off. (See Exhibits 34, 36, 40, 41 <br />10. Second floor is unfinished. Kraft faced fiberglass insulation has been partially <br />installed in the rafters and polyethylene sheet plastic has been installed over the <br />top creating a double vapor barrier. There are multiple signs of areas where <br />trapped moisture is present between the paper face of the insulation and the <br />polyethylene sheeting, and blackened areas that appear to be mold is present <br />throughout; Verification should be made to determine mold presence throughout <br />the second floor area. (See Exhibits 38, 39, 4 <br />11. Guard is missing along the stair opening. (See Exhibits 40, 41 <br />12. High voltage electrical wiring is present and exposed throughout the second floor. <br />There are open and exposed wires and electrical boxes throughout. (See Exhibits <br />37, 42, 43) <br />13. The basement was inaccessible. Debris and garbage was blocking the path to the <br />basement stairs, upon crawling over the garbage to get to the basement stairs <br />garbage and debris is blacking the stairway to the basement (It appears that <br />garbage has been thrown down the basement stairway, filled the stairway and <br />3800 Laverne Avenue North * Lake Elmo * Minnesota * 55042 * E51.747.390 <br />
The URL can be used to link to this page
Your browser does not support the video tag.