GENERAL CONSTRUCTION NOTES <br />CODE COMPLIANCE <br />1.THE FACILITY IS AN UNOCCUPIED WIRELESS FACILITY. EQUIPMENT ROOMS ARE NOT MANNED, ARE <br />NOT HABITABLE, AND DO NOT REQUIRE POTABLE WATER, SEWER CONNECTIONS OR A.D.A. <br />ACCESS ACCOMMODATIONS. <br />2.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL <br />APPLICABLE STANDARDS, CODES, ORDINANCES, RULES, REGULATIONS, ORDINANCES, AND <br />MANUFACTURER'S RECOMMENDATIONS. WHEN TWO OR MORE ARE IN CONFLICT, THE MOST <br />STRINGENT PROVISION SHALL BE FOLLOWED. <br />3.CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, <br />REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE <br />OF THE WORK. WHERE LICENSING IS REQUIRED, CONTRACTOR SHALL OBTAIN ALL REQUIRED <br />LICENSES PRIOR TO BEGINNING WORK. <br />4.MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL <br />APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE <br />JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. <br />5.CONTRACTOR TO COORDINATE WITH LOCAL JURISDICTION FOR ANY CODE RELATED QUESTIONS. <br />ALL JURISDICTION REQUIRED CHANGES ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />GENERAL CONDITIONS <br />6.DO NOT SCALE DRAWINGS. <br />7.THESE DESIGNED DOCUMENTS ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO SHOW <br />FINAL CONDITIONS., UNLESS NOTED OTHERWISE. <br />8.THE CONTRACTORS SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD <br />MEASUREMENTS. NOTIFY THE AE PROJECT MANAGER IF ANY DISCREPANCIES ARE FOUND PRIOR <br />TO PROCEEDING WITH WORK. <br />9.EXTERIOR DIMENSIONS ARE TO FACES OF EXTERIOR WALLS. <br />10.DIMENSIONS ON PLANS ARE TO FINISH FACES OR CENTERLINES OF COLUMNS UNLESS NOTED <br />OTHERWISE. <br />11.DIMENSIONS TO DOOR OPENINGS ARE TO R.O. IN MASONRY & CONCRETE AND TO JAMB OPENING <br />IN STUDWALLS. VERIFY DOOR SIZE W/ SCHEDULE. <br />12.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGNED. MINOR MODIFICATIONS MAY BE <br />REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE <br />INCLUDED AS PART OF THE WORK. <br />13.REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY <br />DRAWING, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE <br />SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY <br />SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL <br />NOTIFY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY <br />IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH <br />ORIENTATION AS DEPICTED ON THE PLAT OF SURVEY. THE CONTRACTOR SHALL ASSUME SOLE <br />LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT/ENGINEER. <br />14.EVERY EFFORT HAS BEEN MADE BY THE ARCHITECT / ENGINEERS TO PROVIDE ACCURATE AND <br />COMPLETE DESIGNED DOCUMENTS THOUGH MINOR ERRORS AND OMISSIONS MAYBE CONTAINED <br />WITHIN THE DOCUMENTS. THESE SHALL NOT EXCUSE THE CONTRACTOR FROM PROVIDING AN <br />ACCURATE PROPOSAL AND COMPLETING THE PROJECT IN ACCORDANCE WITH THE INTENT OF THE <br />DESIGNED DOCUMENTS. <br />15.IT IS THE EXPRESS INTENT OF THE PARTIES INVOLVED IN THIS PROJECT THAT THE CONTRACTOR <br />OR SUBCONTRACTOR OR INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES SHALL <br />EXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCTION MANAGER, THE OWNER, AND <br />THEIR AGENTS, FROM ANY LIABILITY WHATSOEVER AND HOLD THEM HARMLESS AGAINST LOSS, <br />DAMAGES, LIABILITY OR ANY EXPENSE ARISING IN ANY MATTER FROM A WRONGFUL OR <br />NEGLIGENT ACT, OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT <br />DOCUMENTS, OR FROM THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR <br />PROCEDURES, OR FAILURE TO CONFORM TO THE STATE SCAFFOLDING ACT IN CONNECTION WITH <br />THE WORK. <br />CONTRACTOR'S RESPONSIBILITIES <br />16.PRIOR TO THE SUBMISSION OF A BID, THE CONTRACTOR SHALL VISIT THE JOB SITE, REVIEW ALL <br />DESIGNED DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, CONFIRMING THAT THE WORK CAN <br />BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR IDENTIFYING ANY ANY DISCREPANCIES BETWEEN ACTUAL <br />CONDITIONS AND DESIGNED DOCUMENTS, NOTIFYING THE CONSTRUCTION MANAGER AND <br />ARCHITECT/ENGINEER OF SUCH, AND SHALL OBTAIN WRITTEN CLARIFICATION PRIOR TO <br />BEGINNING THE WORK. <br />17.IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT EXTENT OF WORK, <br />COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, UTILITIES, <br />ETC., NECESSARY TO COMPLETE THEIR PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. <br />18.WHILE REVIEWING THE DESIGNED DOCUMENTS, THE CONTRACTOR SHALL IDENTIFY ANY ITEMS <br />WHERE THE DESIGNED INTENT IS UNCLEAR AND OBTAIN WRITTEN CLARIFICATIONS PRIOR TO <br />FURNISHING A BID. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED <br />BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT <br />DOCUMENTS. ANY REQUEST FOR ALTERATIONS TO THE DESIGNED INTENT SHALL BE PROVIDED IN <br />WRITING FOR REVIEW AND APPROVAL. <br />19.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE MOST RECENT DESIGNED DOCUMENTS <br />AND ENSURING THEY ARE DISTRIBUTED AND ARE FOLLOWED BY ALL PERSONNEL INVOLVED IN <br />THE PROJECT. <br />20.CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATION FROM THE CARRIER PRIOR TO <br />PURCHASING ANY MATERIALS OR STARTING ANY WORK. <br />21.CONTRACTOR SHALL, EXCEPT AS SPECIFICALLY AGREED OTHERWISE, PROVIDE ALL NECESSARY <br />MATERIALS, LABOR AND EQUIPMENT TO COMPLETE THE INSTALLATION AS DESCRIBED IN <br />DESIGNED DOCUMENTS. CONTRACTOR TO CLARIFY PROVIDED MATERIALS PRIOR TO FURNISHING <br />A BID. <br />22.ALL FURNISHED MATERIALS SHALL MEET CARRIER SPECIFICATIONS AND MINIMUM REQUIREMENTS <br />FOR THE PROJECT. ANY SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY CARRIER <br />CONSTRUCTION MANAGER PRIOR TO PURCHASE AND INSTALLATION. <br />23.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS <br />AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES AND MATERIALS; AND FOR <br />COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND <br />COORDINATION WITH THE CONSTRUCTION FIELD ENGINEER AND WITH THE LANDLORD'S <br />AUTHORIZED REPRESENTATIVE , COORDINATING ACCESS, AND COMPLIANCE WITH ANY <br />REQUIREMENTS IMPOSED BY THE LANDLORD. <br />24.CONTRACTOR TO PROVIDE CLOSE OUT PACKAGE WITH ALL TEST RESULTS, SETTING SCREEN <br />SHOTS, RELEVANT CATALOGS / CUT SHEETS, INSTRUCTION SHEETS AND A SET OF RED-LINED <br />AS-BUILT DRAWINGS PRIOR TO FINAL BILLING. <br />CONDITION OF SITE <br />25.CONTRACTOR SHALL MAKE PROVISIONS TO PROTECT EXISTING SITE FINISHES AS MUCH AS <br />POSSIBLE. ANY IMPACT TO SITE AND SURROUNDINGS SHALL BE MITIGATED AND CONTRACTOR <br />SHALL RETURN SITE TO PRE-CONSTRUCTION CONDITIONS. <br />26.WORK AREA SHALL BE KEPT FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND <br />ORDERLY AS MUCH AS POSSIBLE. MEANS OF EGRESS SHALL BE KEPT CLEAR AT ALL TIMES. <br />27.ALL DEMOLISHED AND UNUSED MATERIALS SHALL BE REMOVED FROM SITE AND TRACKED ASSETS <br />LOGGED AND RETURNED TO CARRIER FOR DISPOSAL OR RE-USE. CONTRACTOR TO KEEP THE SITE <br />CLEAN, FREE OF HAZARDS, PROPERLY DISPOSE OF ALL RUBBISH, AND REMOVE TRASH AND <br />REFUSE DAILY. BURY NOTHING ON SITE. NO SOLID WASTE RECEPTACLE WILL BE SITED. <br />SITE WORK <br />1.CONTRACTOR TO VERIFY STATE REQUIREMENTS FOR UTILITY LOCATION SERVICES AND <br />EXCAVATION CONTRACTOR SHALL NOTIFY STATE OR LOCAL NOTIFICATION CENTER AS REQUIRED <br />PRIOR TO ANY SITE DISTURBANCES. <br />2.REASONABLE EFFORTS HAVE BEEN MADE TO IDENTIFY EXISTING UTILITIES. THE CONTRACTOR IS <br />RESPONSIBLE FOR IDENTIFYING ALL UTILITIES, SHOWN OR NOT, AND PROTECTING THEM FROM <br />DAMAGE. EXCAVATION CONTRACTOR TO OBTAIN REQUIRED LOCATES PRIOR TO STARTING WORK. <br />3.CONTRACTOR SHALL PROTECT ALL SITE FINISHES AND IMPROVEMENTS AND RETURN ALL TO PRE <br />WORK CONDITION. IF EXTERIOR SITE IMPROVEMENTS ARE REQUIRED, CONTRACTOR TO INSTALL <br />AND MAINTAIN DRAINAGE / RUNOFF MITIGATION MEASURES THROUGH OUT THE PROJECT AND <br />REVEGETATE AREA TO RETURN IT TO ORIGINAL CONDITIONS. <br />4.GRUB AND DISPOSE OF ALL ORGANIC MATERIAL PRIOR NO FILL OR EARTHWORK TO OCCUR WITH <br />ON OR WITH FROZEN MATERIAL <br />STRUCTURAL NOTES <br />1.0 GENERAL CONDITIONS <br />1.1 NO STRUCTURAL ALTERATIONS ARE TO BE MADE TO THE FACILITY UNLESS SPECIFICALLY NOTED. <br />1.2 ALL STRUCTURAL SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR <br />WRITTEN APPROVAL PRIOR TO FABRICATION. <br />2.0 CONCRETE AND MASONRY <br />2.1 ALL CONCRETE WORK SHALL CONFORM WITH ACI. 318 OR LATEST. DETAIL REINFORCING IN <br />CONFORMANCE WITH ACI. SP66 LATEST. <br />2.2 NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY <br />THE STRUCTURAL ENGINEER. LAP SPLICES WHERE PERMITTED SHALL BE A MINIMUM OF 30 BAR <br />DIAMETERS. <br />2.3 PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT POSITIONS SHOW ON <br />DRAWINGS. <br />2.4 WIRE FABRIC REINFORCEMENT MUST LAP ONE FULL MESH AT SIDE AND END LAPS SHALL BE <br />TIED TOGETHER. <br />2.5 CURE AFTER FINISHING CONCRETE. KEEP MOIST FOR 7 DAYS AFTER POURING. <br />2.6 COMPACT STRUCTURAL FILL 95% PROCTOR DENSITY PRIOR TO PLACING CONCRETE UNDER <br />SLABS. <br />2.7 1/4" CHAMFER ON ALL CORNERS AND EDGES. <br />3.8 ALL CONCRETE SHALL BE PORTLAND, TYPE 1 CEMENT WITH A MINIMUM OF 28 DAY STRENGTH <br />OF 3000 PSI., 4" SLUMP AND A MINIMUM AIR ENTRAPMENT OF 4%. <br />2.9 ALL REINFORCING STEEL SHALL BE GRADE 60. ALL REINFORCING MESH SHALL CONFORM TO <br />ASTM A 185. <br />2.10 CONTRACTOR TO OBTAIN X-RAY OR GPR (IF APPLICABLE) OF ANY CONCRETE OR MASONRY <br />STRUCTURES, IDENTIFYING ALL EMBEDMENT PRIOR TO CUTTING, DRILLING OR OTHER ACTIVITY <br />WHICH COULD CAUSE DAMAGE. AVOID ALL EMBEDMENT. OBTAIN APPROVAL FROM <br />STRUCTURAL ENGINEER PRIOR TO IMPACTING ANY STRUCTURAL FACILITIES. <br />3.0 STRUCTURAL STEEL <br />3.1 CHANNELS, ANGLES AND PLATES SHALL BE ASTM A36 MATERIAL, UNLESS NOTED OTHERWISE. <br />3.2 SQUARE AND RECTANGULAR TUBE STEEL HSS SECTIONS SHALL BE ASTM A500, GRADE B <br />(Fy = 46 ksi) MATERIAL. <br />3.3 ROUND PIPE SECTIONS SHALL BE ASTM A53, GRADE B (Fy =35 ksi) MATERIAL. <br />3.4 DESIGNED, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE “AISC <br />SPECIFICATION FOR THE DESIGNED, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR <br />BUILDINGS”, WITH COMMENTARY AND THE “CODE OF STANDARD PRACTICE”. <br />3.5 ALL STEEL SHALL HAVE ONE COAT OF SHOP PRIMER. DO NOT PAINT AREAS WITHIN 3” OF BOLTS, <br />WELDS OR HEADED STUDS. <br />3.6 ALL OUTDOOR STEEL ITEMS SHALL BE HOT DIPPED GALVANIZED PER ASTM A123. <br />3.7 BOLTS SHALL BE HIGH STRENGTH BOLTS, A325, CONFORMING TO ASTM SPECIFICATIONS. ALL <br />CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS. <br />3.8 WELDING SHALL BE CONDUCTED BY CERTIFIED WELDERS AND SHALL CONFORM TO THE AWS <br />CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION. <br />3.9 WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE 3/16" MINIMUM UNLESS <br />OTHERWISE NOTED. <br />3.10 WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDED PROCEDURE SPECIFICATION <br />(WPS) AS PER AWS D1.1 , D1.3 AND D1.4. <br />3.11 ONLY PRE-QUALIFIED WELDING PROCEDURES SHALL BE USED. <br />3.12 UNLESS SPECIFICALLY ADDRESSED IN THE SPECIFICATIONS OR THE DETAILS, ALL STEEL ITEMS <br />PERMANENTLY EXPOSED TO EARTH OR WEATHER SHALL BE CORROSION-RESISTANT BY <br />GALVANIZING OR BY THE USE OF STAINLESS STEEL. <br />3.13 ALL FIELD WELDS ON GALVANIZED MATERIAL SHALL BE BRUSH-COATED WITH A ZINC-RICH PAINT <br />3.14 ANY DAMAGED GALVANIZING OR PAINT TO BE FIELD REPAIRED WITH 'COLD-GALV' OR <br />APPROPRIATE PAINT UNDER CONDITIONS APPROVED BY PRODUCT MANUFACTURER. <br />4.0 FIBER REINFORCED PLASTICS <br />4.1 ALL FRP MATERIAL SHALL BE EXTREN SERIES 500 OR EQUIVALENT, PRODUCED BY THE <br />PULTRUSION METHOD. <br />4.2 ALL ADHESIVE RESIN SHALL BE PLEXUS METHACRYLATE OR AN EQUIVALENT ADHESIVE RESIN <br />THAT IS COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPES. <br />4.3 ALL FRP CONNECTIONS SHALL BE FULLY-BONDED AT EACH SIDE WITH A 1/4” PLATE AND A <br />MINIMUM OF (2) 3/8” DIAMETER FLATHEAD FRP SCREWS PER MEMBER. <br />4.4 ISOPLAST NUTS AND BOLTS SHALL BE TIGHTENED TO A SNUG-TIGHT FIT PLUS AN ADDITIONAL <br />1/2 TURN, PRIOR TO BEING LOCKED WITH EPOXY. <br />4.5 ALL PANELS / SHEATHING SHALL BE FULLY BONDED WITH 3/8” FLATHEAD FRP SCREWS AT 12” O.C. <br />4.6 ALL FIELD CUT AND DRILLED EDGES, HOLES AND ABRASIONS SHALL BE SEALED WITH A <br />CATALYZED EPOXY RESIN COMPATIBLE WITH THE MANUFACTURER'S ORIGINAL RESIN. <br />(E) OVERHEAD ELEC. <br />WATER LINE <br />SANITARY SEWER(N) OVERHEAD ELEC. <br />CHAIN LINK FENCE <br />WOODEN FENCE <br />PROPERTY LINE <br />LEASE LINE <br />EASEMENT <br />ITEM TO BE DEMOLISHED <br />1 <br />ELEVATION A <br />ENLARGED VIEW <br />FE <br />SECTION CUT <br />FIRE EXTINGUISHER <br />STRUCTURAL COLUMN <br />GRID LINES AND LABELS <br />DATUM OR <br />WORKING POINT <br />X X <br />OH-P OH-P SS SS <br />W W <br />OH-P OH-P <br />[ ][ ][ ][ ] <br />XXXX <br />X <br />XXXX <br />X <br />XXXX <br />X <br />ELEVATION <br />MARKER <br />SPOT <br />ELEVATION <br />@ AT <br />°DEGREES <br />Ø DIAMETER <br />A/C AIR CONDITIONER <br />APPROX.APPROXIMATE <br />ARCH.ARCHITECTURAL <br />A.F.F.ABOVE FINISH FLOOR <br />A.F.G.ABOVE FINISH GRADE <br />ATS AUTOMATIC TRANSFER SWITCH <br />AWS ADVANCED WIRELESS SYSTEM <br />BBU BATTERY BACK UP <br />BCEM BASE CHANNEL ELEMENT MODULE <br />BLDG.BUILDING <br />B.O.BOTTOM OF <br />CLG.CEILING <br />COL.COLUMN <br />CONC.CONCRETE <br />DBL.DOUBLE <br />DIA.DIAMETER <br />DIM.DIMENSION <br />DISC.DISCONNECT <br />DN.DOWN <br />DWG.DRAWING <br />(E)EXISTING <br />EA.EACH <br />ELEV.ELEVATION <br />ELEC.ELECTRICAL <br />EQ.EQUAL <br />EXT.EXTERIOR <br />F.O.FIRE EXTINGUISHER <br />FIN.FINISH <br />FLR.FLOOR <br />FUT.FUTURE <br />GA.GAUGE <br />GALV.GALVANIZED <br />GEN.GENERATOR <br />GPS GLOBAL POSITIONING SYSTEM <br />GWB.GYPSUM WALLBOARD <br />H.M.HOLLOW METAL <br />HORZ.HORIZONTAL <br />HR.HOUR <br />HT.HEIGHT <br />ILC INTEGRATED LOAD CENTER <br />INT.INTERIOR <br />L.F.LINEAR FEET <br />MAX.MAXIMUM <br />MECH.MECHANICAL <br />MFGR.MANUFACTURER <br />MGB MAIN GROUND BAR <br />MIN.MINIMUM <br />MSDS MATERIAL SAFETY DATA SHEET <br />MTL.METAL <br />MTS MANUAL TRANSFER SWITCH <br />(N)NEW <br />N.T.S.NOT TO SCALE <br />O.C.ON CENTER <br />O.D.OUTSIDE DIAMETER <br />OVP OVER VOLTAGE PROTECTION <br />PCS PERSONAL COMMUNICATIONS SERVICE <br />RAD.RADIUS <br />R.O.ROUGH OPENING <br />RRU REMOTE RADIO UNIT <br />SHTG.SHEATHING <br />SIM.SIMILAR <br />SPEC.SPECIFICATION <br />S.S.STAINLESS STEEL <br />STL.STEEL <br />STRUCT.STRUCTURAL <br />T.C.TEMPERATURE CONTROL <br />TELCO TELECOMMUNICATIONS <br />T.O.TOP OF <br />TYP.TYPICAL <br />U.G.UNDERGROUND <br />U.N.O.UNLESS NOTED OTHERWISE <br />VERT.VERTICAL <br />V.I.F.VERIFY IN FIELD <br />W/WITH <br />OH-F OH-F (E) OVERHEAD FIBER <br />OH-F OH-F (N) OVERHEAD FIBER <br />COAX COAX (E) COAX <br />COAX COAX (N) COAX <br />HYBRID HYBRID (E) HYBRID CABLE <br />HYBRID HYBRID (N) HYBRID CABLE <br />UG-F UG-F (E) UNDERGROUND FIBER <br />UG-F UG-F (N) UNDERGROUND FIBER <br />UG-P UG-P (E) UNDERGROUND ELEC. <br />UG-P UG-P (N) UNDERGROUND ELEC. <br />GAS GAS GAS LINE <br />ABBREVIATIONS <br />LINETYPES <br />ABBREVIATIONS <br />A 02.05.25 EXHIBIT GW <br />B 02.20.25 FINAL EXHIBIT GW <br />Description:Rev:Date:By: <br />SHEET NUMBER: <br />SHEET TITLE: <br />DRAWN BY:CHK BY:APV BY: <br />PROJECT INFORMATION: <br />T: <br />\ <br />N <br />o <br />n <br />- <br />C <br />O <br />\ <br />A <br />1 <br />N <br />0 <br />3 <br />7 <br />7 <br />A <br />\ <br />T <br />e <br />m <br />p <br /> <br />S <br />i <br />t <br />e <br />\ <br />A <br />& <br />E <br />\ <br />C <br />A <br />D <br />\ <br />A <br />1 <br />N <br />0 <br />3 <br />7 <br />7 <br />A <br />_ <br />T <br />e <br />m <br />p <br /> <br />S <br />i <br />t <br />e <br />_ <br />A <br /> <br />a <br />n <br />d <br /> <br />E <br />_ <br />C <br />D <br />s <br />. <br />d <br />w <br />g <br /> P <br />L <br />O <br />T <br /> <br />D <br />A <br />T <br />E <br />: <br /> <br />2/ <br />2 <br />0 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />B <br />Y <br />: <br />Ga <br />r <br />y <br /> <br />W <br />a <br />t <br />t <br />s <br />THIS WORK WAS PREPARED BY MYSELF OR UNDER MY <br />SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER <br />MY OBSERVATION. ALL SCALES ARE SET FOR 11"x17" <br />GW CM CA <br />PR <br />E <br />L <br />I <br />M <br />I <br />N <br />A <br />R <br />Y <br />990 SOUTH BROADWAY, DENVER, CO 80209 <br />SITE NAME: <br />A1N0510A RELO TEMP SITE <br />SITE ID: <br />A1N0510A <br />ALT ID: <br />SITE ADDRESS: <br />3303 LANGLEY COURT <br />LAKE ELMO, MN 55042 <br />SITE COUNTY: <br />WASHINGTON COUNTY <br />4751 FOX STREET, DENVER, CO 80216 <br />GENERAL NOTES <br />GN1.0