My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
#11 - Drake and DQ Preliminary Plat and PUD
LakeElmo
>
City Council
>
City Council Meeting Packets
>
2020's
>
2023
>
03-21-23
>
#11 - Drake and DQ Preliminary Plat and PUD
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 1:23:40 PM
Creation date
9/29/2025 1:20:51 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED BUILDING50,527 S.F.FFE = 982.00NOPARKING NOPARKING NOPARKING <br />STS >>STS >>STS>>STS>>STS>>STS>>STS >>STS>>STS>>STS>>SAN >SAN >SAN >SAN >SAN >SAN >SAN>SAN>SAN>SAN>SAN>SAN>SAN>STS>>STS>>STS>>STS >>STS >>STS >>STS >>STS >>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS >>STS >>STS >>STS >> <br />ST <br />S>>MH-2RIM: 975.79INL (W): 964.67INL (N): 964.67INV: 962.6748" DIAR-1642SEE DETAIL C7.3/8MH-1RIM: 976.40INL (W): 958.92INL (N): 958.92INV: 956.9248" DIAR-1642SEE DETAIL C7.3/870' - 6" PVC@ 6.49%178' - 8" PVC @ 2.10%55' - 8" PVC @ 2.10%267' - 8" PVC @ 2.10%STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS >>STS >>STS >>8" 90° BEND2" WATER SERVICE CONNNECTION6" FIRE SERVICE CONNECTION8" X 6" TEE8" X 2" TEE8" X 6" TEE8" X 6" TEE8" X 8" TEE8" 30° BEND8" X 8" TEESTS>>8" WATER8" WATER6" WATER8" WATER8" WATER8" WATER 8" WATER 8" WATER8" WATER8" WATER8" WATER8" <br /> <br />W <br />A <br />T <br />E <br />R 8" 45° BEND8" X 8" TEE8" 30° BEND8" 22.5° BEND8" 45° BEND8" WATER8" X 8" TEE8" CAPW/ MEGA LUGS8" X 6" TEE8" CAPW/ MEGA LUGS8" 90° BEND8" X 6" TEE8" WATER8" STUB 2INV: 970.298" GATE VALVE8" GATE VALVESTS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>6" SAN SERVICEINV: 972.5020' - 6" PVC@ 2.10%6" STUB 1INV: 959.348" GATE VALVE8" GATE VALVEELECCOMMGAS <br />ELECGASCOMMELECGASCOMMCOMMGASELECELECGASCOMMEXISTING CONNECTIONINL (NW): 955.76CORE DRILL W/ BOOT6" GATE VALVE2" CURB STOPFDCSAN >51' - 6" PVC@ 6.49%CLEAN OUTINL (W): 967.98INV: 967.98LSSLSSLSSLSS DRAINAGE & UTILITY EASEMENTDRAINAGE & UTILITY EASEMENT30' DRAINAGE & UTILITY EASEMENT30' DRAINAGE & UTILITY EASEMENT30' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENT10' DRAINAGE & UTILITY EASEMENTDRAINAGE &UTILITYEASEMENTDRAINAGE & UTILITYEASEMENT10' DRAINAGE &UTILITY EASEMENT5' DRAINAGE &UTILITY EASEMENT10' DRAINAGE &UTILITY EASEMENT5' DRAINAGE &UTILITY EASEMENT30' DRAINAGE &UTILITY EASEMENTTEAST INFILTRATION BASINHWL=972.74BTM=968.20(PRIVATELY OWNED AND MAINTAINED)SE PONDHWL=971.48NWL=967.50BTM=964.5025' WETLAND BUFFER18" X 29" ARCH PIPE FESINV=956.6218" X 29" ARCH PIPE FESINV=957.3318" X 29" ARCH PIPE FESINV=957.32CABX 18" FES ()INV=958.00 ()ST STMHRE=0.00COBXCABX <br />SS SSMH <br />RE=965.67 <br />CABX <br />CBRE=964.9612" FES ()INV=962.35 ()CABXTNH <br />18" FES () <br />INV=966.56 ()18" FES ()INV=967.75 ()SS SSMHRE=964.05INV=955.56 (12" PVC-NW)INV=955.56 (12" PVC-NE)15" FES ()INV=992.22 ()STMH <br />RE=991.07 <br />INV=994.01 ()15" FES ()INV=991.88 ()SKIMMER FL LOWRE=996.58-LOWRE=997.41-HIGHINV=992.28 (W)INV=992.41 (E)WIER INV=992.93TOP WEIR=994.14SUMP ELEV=991.9447" FES ()INV=991.21 () <br />(TRUNK HIGHWAY NO. 12) <br />INTERSTATE HIGHWAY NO. 94 HUDSON BLVD.MFC PROPERTIES 94 LMTD PARTNSPPID: 3402921440009(COMMERCIAL ZONING)CM PROPERTIES 94 LMTD PARTNSPPID: 3402921440019(COMMERCIAL ZONING)ALWIN CHILDREN LLC <br />PID: 3402921430006 <br />(COMMERCIAL ZONING) <br />CONTINENTAL 483 FUND LLC <br />PID: 3402921440012 <br />(RESIDENTIAL/PUD ZONING) <br />UNION PARK TOWNHOME ASSOCPID: 3402921430076(RESIDENTIAL/PUD ZONING) <br />PID: 3402921440004 <br />HIGHWAY EASEMENT PER DOC. NO. 90695 <br />ACCESS CONTROL PER DOC. NO. 613150Public StreetHUDSON <br />B <br />L <br />V <br />D. <br />Public Str <br />e <br />etB-1B-2B-3B-4B-5B-8B-7B-6B-9B-10B-11B-13B-12RETAINING WALL-GRAVEL-WETLAND #1STS >>STS >>STS>>STS>>STS>>STS>>STS >>STS>>STS>>STS>>SAN >SAN >SAN >SAN >SAN >SAN >SAN>SAN>SAN>SAN>SAN>SAN>SAN>STS>>STS>>STS>>STS >>STS >>STS >>STS >>STS >>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS >>STS >>STS >>STS >> <br />ST <br />S>>MH-2RIM: 975.79INL (W): 964.67INL (N): 964.67INV: 962.6748" DIAR-1642SEE DETAIL C7.3/8MH-1RIM: 976.40INL (W): 958.92INL (N): 958.92INV: 956.9248" DIAR-1642SEE DETAIL C7.3/870' - 6" PVC@ 6.49%178' - 8" PVC @ 2.10%55' - 8" PVC @ 2.10%267' - 8" PVC @ 2.10%STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS>>STS >>STS >>STS >>8" 90° BEND2" WATER SERVICE CONNNECTION6" FIRE SERVICE CONNECTION8" X 6" TEE8" X 2" TEE8" X 6" TEE8" X 6" TEE8" X 8" TEE8" 30° BEND8" X 8" TEESTS>>8" WATER8" WATER6" WATER8" WATER8" WATER8" WATER 8" WATER 8" WATER8" WATER8" WATER8" WATER8" <br /> <br />W <br />A <br />T <br />E <br />R 8" 45° BEND8" X 8" TEE8" 30° BEND8" 22.5° BEND8" 45° BEND8" WATER8" X 8" TEE8" CAPW/ MEGA LUGS8" X 6" TEE8" CAPW/ MEGA LUGS8" 90° BEND8" X 6" TEE8" WATER8" STUB 2INV: 970.298" GATE VALVE8" GATE VALVESTS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>STS >>6" SAN SERVICEINV: 972.5020' - 6" PVC@ 2.10%6" STUB 1INV: 959.348" GATE VALVE8" GATE VALVEELECCOMMGAS <br />ELECGASCOMMELECGASCOMMCOMMGASELECELECGASCOMMEXISTING CONNECTIONINL (NW): 955.76CORE DRILL W/ BOOT6" GATE VALVE2" CURB STOPFDCSAN >51' - 6" PVC@ 6.49%CLEAN OUTINL (W): 967.98INV: 967.98LSSLSSLSSLSS <br />C7.32HYDRANT &GATE VALVEC7.32HYDRANT &GATE VALVEC7.32HYDRANT &GATE VALVEC7.32HYDRANT &GATE VALVEC7.37WETTAPC7.37WETTAPFUTURE WATERMAIN282828FUTURE WATERMAIN23232323252525252831262621212121PROJECT NUMBER:DRAWING TITLEISSUE / REVISIONELECTRIC AUTOSALES & SERVICEHUDSON BLVD N.LAKE ELMO, MN 55042SHEET NUMBER©DENVER, CO 80209www.drakeres.comTel. 303.825.6200496 S. BROADWAYDRAKEMOTOR PARTNERS VANCOUVER, LLCAUG. 29, 2022 CITY SUBMITTALDRS22002I hereby certify that this plan was prepared by me, or under my direct supervision, andthat I am a duly Licensed Professional Engineer under the laws of the state ofMINNESOTA.Signature shown is a digital reproduction of original. Wet signed copy of this plan on file atLandform Professional Services, LLC office and is available upon request.Tom O. MeyerLicense No:Date:105 South Fifth AvenueSuite 513Minneapolis, MN 55401Tel: 612-252-9070Fax: 612-252-9077Web: landform.netLandform®and Site to Finish®are registered service marks of Landform Professional Services, LLC.OCT. 26, 2022 REVIEW SETJAN. 25, 2023 PRELIM BID SETFEB. 13, 2023 CITY SUBMITTALWATER & SANITARYC4.2NORTH0 60 120Pipe MaterialsWatermainDIP Class 52 (ANSI A21.51/AWWA C151)Private Sanitary Sewer PVC Schedule 40 (ASTM: D1785, D2665, F891, F1488, F1760)Storm SewerPVC Schedule 40 (ASTM: D1785, D2665, F891, F1488, F1760)RCP 12"-18" Class 5 (ASTM C76)RCP 21" Class 4 (ASTM C76)RCP 24"-48" Class 3 (ASTM C76)Drain TilePVC (ASTM D2729)Contact utility service providers for field location of services 72 hours prior to beginning.Contractor to field verify location and elevation of all utility points of connection prior to construction of any proposed utilities.Contractor to notify Engineer immediately if there is any discrepancy.Contractor to pothole all utility crossings prior to construction of new utilities to verify depths of existing lines. Contact Engineerimmediately if any conflicts are discovered.Provide means and measures to protect adjacent property from damage during utility installation.Pipe lengths shown are from center of structure to center of structure or end of end section.Install tracer wire with all non-conductive utilities in accordance with City of Lake Elmo Standards.Connect to City utilities in accordance with City of Lake Elmo Standards.Contact City of Lake Elmo Public Works at 651.747.3940 for wet tap inspection.Maintain 7.5 feet of cover on water.Deflect water to maintain 18-inch minimum outside separation at sewer crossings. Center pipe lengths to provide greatest separationbetween joints.Contact City of Lake Elmo Public Works at 651.747.3940 for flushing and pressure test inspections.The water distribution system shall be disinfected per Minnesota Rules, Part 4714.Provide 4-inch rigid foam (ASTM D1621) insulation on sanitary sewer less than 6 feet deep.Refer to Plumbing plans for sand separator detail. The tank and top slab must be designed to handle traffic and soil loads. The tankmust be protected from freezing and must comply with all local and state codes.All portions of the storm sewer system, located within 10 feet of the building or water service line must be tested in accordance withMinnesota Rules, Part 4714.All joints and connections in the storm sewer system shall be gastight or water tight. Approved resilient rubber joints must be used tomake watertight connections to manholes, catch basins, and other structures.Catch basins in curb and gutter are sumped 2 inches below the gutter grade. Refer to Detail 5 on Sheet C7.3.Rock media in infiltration or filtration systems shall be angular, non-calcareous rock.Irrigation sleeve to be 4 inch Schedule 80 PVC buried 24" below grade. Extend sleeves 3-feet beyond the edge of pavement. Markeach end of sleeve with 3/4-inch rebar 12 inches below finish grade. (Coordinate with irrigation contractor.)Coordinate with Private Utilities to provide electric, natural gas, and communications services to building.The primary electric feed, transformer, and meter are provided and installed by Xcel Energy. The transformer pad design is providedby the Utility and construction is by the Contractor. Contact Utility for pad detail. The secondary electric and conduits shall be installedby the Electrical Contractor.See site lighting plan for additional information.Xcel Energy will furnish and install gas service piping from the mainline to the meter and the meter. Gas service from the meter shallbe installed by the Mechanical Contractor.Provide one 4-inch PVC conduit with pull-string from existing telephone service to building.Provide conduits for cable television and other electronic communication.Coordinate with Mechanical, Plumbing, and Electrical Drawings for locations of service connections and continuation of serviceswithin building.Compact cohesive soils in paved areas to 95% of maximum dry density, Standard Proctor (ASTM D698) except the top 3 feet whichshall be compacted to 100%. compact to 98% density where fill depth exceeds 10 feet. The soils shall be within 3% of optimummoisture content. In granular soils all portions of the embankment shall be compacted to not less than 95% of Modified ProctorDensity (ASTM D1557).Adjust structures to final grade where disturbed. Comply with requirements of Utility. Meet requirements for traffic loading in pavedareas.Reinstall salvaged hydrant2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.19.20.21.22.23.24.25.26.27.28.29.30.31.GENERAL NOTESINFILTRATION / FILTRATION BASIN REQUIREMENTSUTILITY NOTESFor construction staking and surveying services contact Landform at 612.252.9070.Lot 1, Block 1 designed by others and under separate application1.2.Refer to the C3.1 sheet notes for requirements.31.
The URL can be used to link to this page
Your browser does not support the video tag.