My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-08-26 Planning Commission Meeting Packet
LakeElmo
>
Commissions and Committees
>
6 - Planning Commission
>
02 - Packets
>
2020's
>
2026
>
06-08-26 Planning Commission Meeting Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2026 12:43:12 PM
Creation date
6/8/2026 12:40:02 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page: 3 <br /> <br /> <br /> <br />STORMWATER MANAGEMENT <br />1. The proposed subdivision is subject to a Stormwater Management Plan (SWMP) meeting State, <br />South Washington Watershed District (SWWD) and City rules. A SWWD permit is required. <br />2. The Preliminary Plat/Plans propose improvements that reside within the larger Inwood <br />subdivision in which stormwater management provisions have been previously designed, <br />permitted and constructed. <br />3. The allowable maximum impervious surface for each Lot has been documented on the Preliminary <br />Stormwater Management Plan and is consistent with the approved Inwood Stormwater <br />Management Plan. As final construction plans are prepared for the Subdivision, and future lot <br />build-outs, the impervious surfaces must remain below the maximum allowable, and the <br />stormwater drainage systems must be designed to direct runoff to the allocated stormwater <br />management basin. <br />4. The site design will create a maximum of 5.561 acres of new impervious surface once all public <br />improvements and all 5 lots have developed. A maximum of 3.184 acres of new impervious <br />surface will be conveyed and managed through Pond 200 (located east of the site) while a <br />maximum of 2.377 acres of new impervious surface will be conveyed and managed through Pond <br />100 (located on the south side of 5th Street). <br /> The SWMP must be revised to add an exhibit that clearly presents the impervious surface <br />limits for each lot, including impervious surface allowed for each lot within the shoreland <br />district boundary and the impervious surface allowed for each lot outside of the shoreland <br />district boundary. The exhibit must also label and call-out the required storm sewer <br />connection location for each lot together with a delineated drainage shed that is allowed <br />to drain to each connection location. Lot labeling must be consistent with the proposed <br />preliminary and final plat. <br /> The SWMP must be revised to account for and address the new impervious surfaces <br />created within the County right-of-way and bituminous trails. <br /> The Grading Plans and SWMP must be revised to account for the bituminous trail <br />construction along Inwood Avenue and 10th Street and the drainage limits must be clearly <br />identified for the areas allowed to drain to County right-of-way. <br />2. Approval of the Preliminary Plat/Plans for the development is contingent upon all SWMP revisions, <br />as required by the SWWD or other applicable permitting agency, being submitted to the City for <br />review and approval. <br />3. Approval of the preliminary grading and storm sewer plans for the development is contingent upon <br />all grading plans being reviewed and approved by the City Engineer prior to the start of any grading <br />or construction. <br /> The grading plans must include lot corner and lot line spot elevations to clearly define <br />limits of the public right-of-way improvements and tie-in elevations for future lot grading <br />activities. <br /> Overland emergency overflow (EOF) elevations are required throughout the site at all <br />localized low points. Low openings for adjacent structures must maintain 1-foot above <br />any adjacent EOF in the as-built condition. <br /> The grading plans must include minimum low floor and/or low opening elevations for <br />each lot based on the SWMP and emergency overflow elevations. <br /> The storm sewer plans must be revised to eliminate the 21-inch storm sewer stub being <br />extended to Lot 2, Block 2 as runoff from this area to Pond 200 is inconsistent with the <br />proposed SWMP. Connections to existing storm sewer stubs along 5th Street must be <br />called out for use by this Lot and the downstream storm sewer system capacity must be <br />modeled and verified. <br />4. Plan revisions may be required to meet City design standards and to mitigate encroachments.
The URL can be used to link to this page
Your browser does not support the video tag.