<br />~, outdoor temperature is below the winter outdoor design temperature for <br />the locality, -12°F, maintenance of the minimum room temperature shall <br />not be required, provided that the heating system is operating at its full <br />design capacity. <br />Subd. 36. Section 602.4 Occupiable work spaces. When occupied during <br />the period from September 15 to May 15, indoor occupiable work spaces <br />shall be supplied with heat to maintain a temperature of not less than <br />68°F. EXCEPTION: When the outdoor temperature is below the winter <br />outdoor design temperature for the locality, -12°F, maintenance of the <br />minimum room temperature shall not be required, provided that the <br />heating system is operating at its full design capacity. <br />Subd. 37. Section 603.5 Combustion air. In accordance with the Minnesota <br />State Mechanical Code (MSMC), a supply of air shall be provided for <br />complete fuel combustion and for ventilation of the space containing the <br />fuel-burning equipment. <br />Subd. 38. Section 604.1 Facilities required. Every occupied building shall <br />be provided with an electrical system in compliance with the requirements <br />of this section, Section 605, and the National Electrical Code (NEC). as <br />adopted by the MSBC. <br />• Subd. 39. Section 604.2 Service. 1n accordance with the NEC, the size and <br />usage of appliances and equipment shall serve as a basis for determining <br />the need for additional facilities. At a minimum, dwelling units shall be <br />served by a three-wire, 120/240-volt, single-phase electrical service with a <br />rating of not less than 60 amperes. <br />Subd. 40. Section 605.2 Add the following exception: Exception, One <br />permanently installed ceiling light fixture may be provided in lieu of one <br />required receptacle outlet. <br />Subd 41. Section 701. Scope. Una <br />MSFC shat{ govern the minimum <br />relating to structures and exterior <br />and equipment to be provided. <br />ier the provisions of this chapter, the <br />conditions and standards for fire safety <br />premises, including fire safety facilities <br />Subd. 42. Section 702.2 Aisles. In accordance with the MSFC, the required <br />width of aisles shall be unobstructed. <br />Subd. 43. Section 702.3 Locked doors. All means of egress doors shall be <br />readily capable of being opened from the side from which egress is to be <br />made, without the need for keys, special knowledge or effort, except <br />where the door hardware conforms to that permitted by the MSBC. <br />Subd. 44. Section 702.4 Emergency escape openings. Required <br />emergency escape and rescue openings shall be operational from the <br />Page 7 <br />