Building N Site Plan <br /> Planning Case 543-98 <br /> December 28, 1998 <br /> Page 2 <br /> The parking lot for this building is for the most part set back from Program Avenue by a minimum <br /> of ten feet, with the except for an area where the dedicated right-of-way jogs into the property. <br /> While the front yard parking lot setback for a building of this type in an industrial district would <br /> normally be 40 feet, because this is within an approved PUD and is zoned accordingly, the <br /> setbacks can deviate from the norm. The 1994-approved plans indicated the same front setback. <br /> Drainage Considerations: <br /> There is currently a Rice Creek Watershed District (RCWD) permit in force for the previously <br /> approved Building N development. Staff has forwarded a revised set of plans to the district office <br /> for their review. It is likely that the existing permit will need to be amended or a new permit will <br /> need to be obtained. The resolution will stipulate that this permit be obtained from RCWD prior <br /> to final approval. <br /> Parking: <br /> The site plans show a total of 344 parking stalls being provided for the building at a ratio of one <br /> space per 181 square feet of usable space . According to the parking ratios listed in Chapter 1121 <br /> of the City Code, office uses require 3 spaces plus 1 per 175 square feet of floor area and while <br /> warehouse uses require 8 spaces plus 1 per 500 square feet of floor area. The parking provided, <br /> according to these requirements, will be adequate to serve the building as long as office uses do <br /> not exceed 75 percent of the usable floor area of the building (the balance used as warehouse, <br /> storage or manufacturing.) The applicant has indicated that office uses are not expected to <br /> exceed this amount. <br /> Landscaping: The City Forester, Rick Wriskey, reviewed and approved the original landscape <br /> plans. Even though the current landscape plan indicates all of the same species and in the same <br /> general ratios and even exceeds the previous plan by an additional five plantings, staff asked the <br /> Mr. Wriskey to review the revised landscape plan in the event that any of the species have been <br /> recently found to be susceptible to disease or any other problems. He determined that the <br /> proposed landscaping plan was acceptable and appropriate. <br /> Public Safety: The access and drive aisles are in conformance with Fire Department <br /> requirements and standards. There are three entrances from Program Avenue to the site, two of <br /> which are 30 feet wide and are intended for truck traffic and the third, which would be for <br /> automobile traffic only, is 25 feet wide. Because of the angled loading bays at the rear of the <br /> building, truck traffic will enter only from the north driveway and exit only from the south <br /> driveway. There is 45 feet of impervious surface at the rear of the building to sufficiently <br /> accommodate the turning and maneuvering of the trucks. The City Engineer and Director of <br /> Public Works pointed out a possible problem with the south drive, in that it is less than twenty <br /> feet from the adjoining property's driveway, both of which are directly across the street from <br /> Clifton Drive. It was suggested that perhaps Clifton drive could be extended into the Building N <br /> site and the Mounds View Inn property to reduce the potential for traffic conflict. The applicant <br /> did not find this modification acceptable. <br />