Laserfiche WebLink
McDonalds Development Review <br /> Planning Case No. 500-97 <br /> August 20, 1997 <br /> Page 3 <br /> that the McDonalds parcel is 487 feet from the closest edge of Rice Creek. This letter, dated July <br /> 12, 1997, has been attached. The grading and drainage plans have been submitted to Rocky Keehn, <br /> the City's Engineer, for review. In a memo dated August 7, 1997, Mr. Keehn responded that the <br /> overall impervious surface on the site will not increase with this development. However, because of <br /> the relocation of the building, the drainage patterns may shift, causing additional runoff in a particular <br /> area. The applicant has submitted revised drainage plans showing existing and proposed drainage <br /> flows, which have not yet been reviewed by Mr. Keehn. Staff will have a response regarding the <br /> drainage prior to your meeting on August 20, 1997. Mr. Keehn recommends that no water quality <br /> treatment methods be required for this development proposal due to site constraints. <br /> Landscaping: <br /> Much of the existing landscaping present around the perimeter of the lot will be retained. The <br /> landscape plan includes a planting schedule for the trees and shrubs to be added around the building <br /> and in the island separating the two curb cuts. Two larger evergreens existing near the front of the <br /> lot are proposed to be transplanted to the rear of the lot because of the shifted curb cuts. Rick <br /> Wriskey, the City Forester, has not yet reviewed the planting schedule, but will do so before your <br /> meeting on August 20, 1997 at which time I will verbally present his approval or any <br /> recommendations that he has made. <br /> • Lighting <br /> Parking lot lighting will be accomplished by four 24-foot tall standards, each with two 1000 watt <br /> metal halide lamps. The photometric analysis provided by the applicant indicates that the lighting <br /> meets the requirement as set forth in Section 1103.09 of the Zoning Code, whereby light from the <br /> property shall not exceed one foot-candle as measured from the centerline of adjacent streets. The <br /> Code also states that no bulbs may be visible from adjoining properties and that they be hooded or <br /> shielded to prevent glare. There was no indication on the photometric analysis of any wall-mounted <br /> lighting for the building. This will need to be clarified by the applicant. <br /> Signage: <br /> The existing pylon sign on the property will be retained in its present position. No other ground- <br /> mounted signage is proposed other than four small directional signs at the entries to the site. On the <br /> building front, there will be approximately 40 square feet of signage which will display the name of <br /> the restaurant. On either building side, the company logo will be attached to the wall. Both signs are <br /> approximately 20 square feet in area. <br /> Parking: <br /> Given estimated square-footages for the kitchen and dining areas of the proposed building at 1,000 <br /> square feet and 1,600 square feet respectively, the applicant would need to provide a minimum of 53 <br /> parking spaces. This total is based on the following ratios: <br /> 1111 Kitchen area (1 space per 80 square feet): 1,000 divided by 80 = 13 spaces <br /> Dining Area(1 space per 40 square feet): 1,600 divided by 40 =40 spaces <br /> Total spaces required: 53 spaces <br />