Laserfiche WebLink
Sunrise CUP <br /> November 12, 1999 <br /> Page 6 • <br /> Development Review Discussion: <br /> Dimensional Requirements: <br /> Required Proposed Met? <br /> Lot Area 1 acre 6.4 acres Met <br /> Front Setback (Long Lake) 35 feet 6 feet Met <br /> Front Setback(County Rd. I) 35 feet 35 feet Met <br /> Sideyard Setbacks 30 feet 105 feet Met <br /> Parking lot Setback(east) 30 feet 60 feet Met <br /> Parking lot Setback(west) 5 feet 2 feet No' <br /> Parking lot Setback(north) 5 feet 80 feet Met <br /> Parking lot Setback(south) 5 feet 400+feet Met <br /> Parking stalls (1:4): 92 stalls 98 stalls Mete <br /> The expansion areas will be of brick construction and will match the exterior of the existing <br /> building. The total area of the expansion planned is 7,477 square feet for a total build out area of <br /> 20,464 after project completion. There will be a new covered entryway that connects to a new <br /> drop-off point adjacent to the parking lot, an expansion and reorientation of the sanctuary to <br /> increase seating capacity to 368 from the existing 275. <br /> There will be an expansion to accommodate additional space for Sunday school services. A 1111 <br /> kitchen area will be added along with some multi-purpose space, conference rooms, and office <br /> space for the Pastor and Church staff. There will not be an increase in services provided by the <br /> facility other than being able to accommodate more members in the sanctuary at a single service, <br /> thus the additional number of parking stalls required by this expansion will be limited to the <br /> increased seating capacity of the sanctuary. <br /> Parking: <br /> As indicated above, the seating capacity of the sanctuary is increasing by nearly 100 seats, from 275 <br /> to 368. Using the required ratio of 1 space per 4 seats, 92 stalls would need to be provided. There <br /> are currently 98 stalls which can be utilized which would then be adequate to accommodate the <br /> expansion. The plans, however, show a possibility of an additional 48 seats in temporary overflow <br /> seating. Church officials do not foresee a need to use these spaces except only rare occasion and as <br /> such is requesting that parking spaces not be required for the temporary seating. Because of their <br /> temporary nature, staff would consent to this request if the Planning Commission were to agree. If <br /> the Planning Commission felt otherwise, the plans could be revised to show"Future Proof of <br /> Parking" which could be built if it becomes clear that additional spaces are required. <br /> 1The parking lot adjacent to Long Lake Road was constructed only two feet from the property line. <br /> Because no plans are being made to repave the parking lot,staff recommends that this be treated as a non- <br /> conformity to be corrected if possible at some point in the future,as allowed in Section 1104.01, Subd.4c(4). <br /> 2 The number of parking stalls required increases to 104 when considering the anticipated future 410 <br /> overflow seating. Because 98 stalls exist,six additional stalls will need to be shown on the site plan as <br /> "Future Proof of Parking." <br />