My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packets - 2001/04/23
MoundsView
>
Commissions
>
City Council
>
Agenda Packets
>
2000-2009
>
2001
>
Agenda Packets - 2001/04/23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 4:47:32 PM
Creation date
8/29/2018 9:45:15 AM
Metadata
Fields
Template:
MV Commission Documents
Commission Name
City Council
Commission Doc Type
Agenda Packets
MEETINGDATE
4/23/2001
Supplemental fields
City Council Document Type
City Council Packets
Date
4/23/2001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 5 <br /> <br /> <br />1005.07 Subd. 7 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />1005.10 Subd. <br />4a(1) <br /> <br /> <br /> <br />1005.04 Subd. 1. <br /> <br /> <br /> <br /> <br /> <br />1005.06 Subd. <br />1d <br /> <br /> <br /> <br /> <br />1005.08 Subd. <br />12a <br /> <br /> <br /> <br /> <br />1005.08 Subd. <br />12a <br /> <br /> <br /> <br /> <br /> <br /> <br />1005.08 Subd. <br />12a <br /> <br /> <br /> <br /> <br />1005.04 Subd. 1 <br /> <br /> <br /> <br />1005.04 Subd. 1 <br /> <br /> <br /> <br /> <br />Replace hallway floor covering, exposed plywood not permitted. <br /> <br /> <br /> <br /> <br />In each dwelling unit, there shall be provided and installed at least one fire extinguisher <br />with a rating of not less than 1A-10BC. Current fire extinguisher shows recharge, <br />needs to be replaced or serviced. <br /> <br />All equipment, fixtures and all building space shall be maintained in a workmanlike state of <br />repair so as to properly and safely perform their intended function. Provide an electrical <br />switch cover in the front bedroom, electrical outlet in entryway addition is <br />ungrounded, provide an electrical outlet cover plate in ½ bath, provide an electrical <br />outlet cover plate in living room outlet by door. <br /> <br />The roof and flashing shall be sound, tight, and have no defects which admit water. Roof <br />drainage shall be adequate to prevent dampness, water, or deterioration in the walls or <br />interior portions. Roof shows evidence of leaking in back bedroom, ceiling sagging. <br /> <br />Every water line, plumbing fixture and drain shall be properly installed, connected, and <br />maintained in working order and must be kept free from obstructions, leaks and defects <br />and capable of performing the function for which is was designed. Toilet in main <br />watercloset runs water constantly, ballcock assembly needs repair. <br /> <br />Every water line, plumbing fixture and drain shall be properly installed, connected, and <br />maintained in working order and must be kept free from obstructions, leaks and defects <br />and capable of performing the function for which is was designed. Bathtub in main <br />watercloset has an unapproved discharge below the spill level of the tub/ cross <br />connection to potable water supply. Replace or relocate discharge to above the <br />spill level of the tub. <br /> <br />Every water line, plumbing fixture and drain shall be properly installed, connected, and <br />maintained in working order and must be kept free from obstructions, leaks and defects <br />and capable of performing the function for which is was designed. Sink in ½ bath is not <br />anchored to wall, plastic handles missing on sink. <br /> <br />All equipment, fixtures and all building space shall be maintained in a workmanlike state of <br />repair so as to properly and safely perform their intended function. Ventilation fan in main <br />watercloset is inoperable, replace fan. <br /> <br />All equipment, fixtures and all building space shall be maintained in a workmanlike state of <br />repair so as to properly and safely perform their intended function. Exhaust for clothes <br />dryer is disconnected. The clothes dryer must be connected to the exhaust vent in <br />an approved manner, no duct tape or screws will be permitted. <br /> <br />The supporting structural members shall be maintained structurally sound, showing no <br />evidence of deterioration and being capable of bearing imposed loads in accordance with <br />the building code. Structural members of entryway addition are sagging, ceiling is <br />deteriorated in the livingroom and back bedroom due to roof leak, structural <br />integrity may be compromised. <br /> <br />The outside accumulation of old machinery, junk, household furnishings or appliances, <br />rusting metal, inoperable/unusable equipment or other debris is prohibited. Remove <br />outside storage of animal cages, inoperable/unusable equipment, aquarium and <br />other debris present.
The URL can be used to link to this page
Your browser does not support the video tag.