PRO P ` I I✓ I REMOVE EXISTING PAVEMENT <br />P N N AS NECESSARY FOR NEW <br />N N I T� I " ZONED: B-3I(HIGHWAY BUSINESS) \ CONNECTION NOTE: ALL EXISTING 8" VCP SANITARY SEWER NOTE: ALL EXISTING b" CIP WATER MAIN <br />AREPLACE PAVEMENT AS PER LOCATED BETWEEN NORTH BUILDING WALL LOCATED BETWEEN EXISTING HYDRANT <br />NOT0 T PLA TEI+✓1 eQISTING ROAD ENTRANCECOUNTY AND/OR CITY AND NEW SANITARY MANHOLE (SANMHI) (NORTH) AND NEW HYDRANT PIPE TEE BLOCK I I REMOVE EXISTING DRIVEWAY ENTRANCE REPLACE WITH SIDEWALK PER COUNTY \ REQUIREMENTS SHALL BE REMOVED OF, AND DISPOSED OF CONNECTION (SOUTH) SHALL BE REMOVED <br />\ OFF-SITE OF, AND DISPOSED OF OFF-SITE <br />REPLACE WITH SIDEWALK PER COUNTY REQUIREMENTS <br />REQUIREMENTS h <br />RIM=906.59 6618 CURB & CONNECT TO EXISTING <br />INV=902.05 a GUTTER (TYP) a 12" CIP WATERMAIN PER <br />CITY REQUIREMENTS <br />RIM=906.86 RIM=907.00 COUNTY ROAD f B618CURBP N COOS RETE S 89 4628 W 965.83 <br />SIDEWALK (TYP) (WET TAP) o <br />INV -894.60 INV SE=901.88 CONCRETE ( ) <br />- INV 5=896.15 - - SIDEWALK (TYP) <br />N 89046'28" E 1318.36 SN 7, SN SN SN SN 8.. C.p. SIN SN EXISTING RIM 07. 4 8° 45° BEND �N EXISTATCING <br />CENTER OF <br />RI =90F 3 O � 8" 22�° BEND \EXISTING SEC. OF SEC. <br />CURB HYDRANT IN V= SIDEWALK <br />G <br />4_1 T GUTTER 2"CIP I V- M I O 8" C900 PVC 8, T.30, R.23, <br />W1/4 CORNER I I I I I I \A CURB TTER (TYP) cuRe c <br />OF SEC. 8, U' CUR CU4y NOTE: EXISTING SANITARY, WATER, AND STORM <br />r� O OHP OHP OHP OHP OHP O p Ems,' <br />T.30, R.23. �n I G STUBS, WHICH WILL NO LONGER BE IN USE, SHALL BE <br />EXISTING _RI=9�MATCH-� _ _ _ � _ _ - - o - \ REMOVED TO THE MAIN AND CAPPED/PLUGGED. <br />iNV=9G�., - - 45° N CONTRACTOR SHALL FIELD VERIFY EXISTING STUBS, <br />SIDEWALK / K 30 ° WHICH MAY NOT BE SHOWN ON THIS PLAN, OR THE <br />EXISTING 30 30 - - -a ° = - - - - - - - - -=�0. �S8 �" - �+ - " I` g cc ASSOCIATED SURVEY. <br />HYDRANT <br />Ivi � OR EOF <br />I CON'C-RF`E <br />SIDEWALK (TYP) 8" SANITARY SERVI SEC. 8, .23. \ \ <br />I (EXISTING VCP SAA SEWER) m Ln <br />[SURFACING <br />E: VERIFY PATIO INV @ BLDG = �`k�� I \ \ <br />ZONED: R-2 v I W/ OWNER \ <br />(SINGLE & TWO FAMILY RESIDENTIAI \ \\ T \ SOUTH BOUND CL <br />CONCRETEI THICKENED EDGE 8" COMBIN�D WATER \ OF STATE TRUNK <br />SIDEWALK (TYP I r�i I ERVICE W/ 8' TE \ \ HIGHWAY NO. 10-62 <br />SIDEWALK (TYP) � � v 47 0 � "'� <br />_ I EAST LINE OF THE I\ VeLVE & BOA Pr <br />OFT OF �� � <br />PROPOSED <br />NEl/4 THE 5 1/4BUILDIN <br />EC. 8, \ �� <br />Lu I MFE = 914.50 ° ' . I 0m \ A ('p \ \ \ \ <br />\ j -{ I GFE = 903.50 \ Off, <br />A �mMma)ffl_ G,6/ <br />O I ac� CONCRETE -9ab ' EDGE <br />I I SIDEWALK (TYP)' 8612 CURB & CURB CUT �, THIo1cENE� <br />O OO I GUTTER (TYP) HYDRANT II II ll2 RB ° SIDEWfLi� (TYP) / \ \ \ \ IT - <br />6" <br />O I 6 B AXE VAL E �1 ( P) 9 I <br />CL: �5 /RIM=905.8 ° 06.11 I \ \ \ C <br />2 v I INV=900.2 ° I I 6" 4 BE I <br />ao <br />Ln ST ST /5T-, <br />BITU IN US I 6" l° N ° EASTINTELIN IN OSE � WEST \ \ \�\ \ \ `'� 9 H <br />ZONED: R-1 (SINGLE FAMILY RESIDENTIAL Q THICKE D EDGE PA EM NT (Y m I I \ \\ \ EXIS G <br />c I 475 FT & 56UTH LINE \ \ <br />RIM -905. SIDEV (TYP) ° OF NORTH 1901 FT \ \ \ \ 'I EWr 01 <br />- I INV -900. 7. v o � OF NEI/4 OF 521/4, O <br />RIM=903.79 I - M= 06.01 SEC. 8, T.30, R.23.\ <br />INV=901.64 ST T ST ST ST ST 15"R.C. -90185/ SW'LY F \ \ \ <br />RIM -904.44 IM=905.87 = STATE TR \ \ \ \\ <br />5-121, V=899.81 CONCRETE I V-9 Tf T z1vo I I 2 -FT V LLEY HIGHWA`' ^' 2 \ \ <br />RIM=903.79 SIDEWALK (TYP) GUTTER JT P) C CRE <br />\ \ SIDE LK ( \ \ <br />INV -901.45 � 903.61 IAll� ARA L L E O ° <br />' THICKENED EDGE <br />R M=903.57 1 F T 5\ <br />I V= 00.6 SIDEWALK (TYP) \ \ <br />2 -FT VALLEY bl CUB OF 61 3 &R.2 KI E M NT \ \ \ <br />MATCH INSULATE' GUTTER (TYP) B I q G ER p \ \ \ \ <br />BL OCK EXISTING I SANITARY SEWER, n r. - - _ - ' I IDD O. I \ \ \ y <br />SIDEWALK AS NECESSARY \ I <br />T IN S CONCRfTE 6"X6' EE I EL ITU <br />/ E N (Y) <br />SIDE (TYP)I cn 6" 45 BENq ^ SFOR E fjAVE ENT (TYP) \� \O \ <br />CONNECT TO EXISTING / FIF/ CURB Cl I 0 I - L - I B612 CUMI US 6612 CURB& <br />SANITARY MANHOLE I ,-, v 6"G ` �_ _ _ _ GUTTER (TY & ° i PA MENT (TY GUTTE�(fYP) <br />\ (FIELD VERIFY) <br />I 30 30 m 9P \�O \ \ \ \ \ <br />CORE DRILL W/ BOOT 363 FT OF I �g TH\- <br />( ) I _ ELECTR1, 4 OF THE SW_ u 6" 1 ° BEND EN ER DOC. T 365.46 T OF <br />THE NE1/4 OF <br />REMOVE EXISTING <br />PAVEMENT AS NECESSARY E <br />FOR NEW CONNECTION - - - - - - <br />6"C900PVC 11 6" C9 PVCH <br />I �_ - - �- -----=�FIP--------------------� \ \ \ <br />REPLACE PAVEMENT AS I - - - - - - SAN H 1 <br />PER CITY REQUIREMENTS HYDRANT <br />8" PVC SANMH3 CONCRETE b" GATE VALVE @ 0.46% I INV S 9897.61 HYDRANT <br />@ 0.46% RIM = 904.75 SIDEWALK (TYP) &BOX CONNECT TO L I INV W = 897.51 6" GATE VALVE <br />CONNECT TO EXISTING INV E = 896.10 6" 450 BEND EXISTING 6" I - Z I INTERSECTION OF RETAINING WALL &BOX <br />WATERMAIN 4 INV NW = 896.00 8612 CURB & WATERMAIN LENGTH = 34 LF CONCRETE \ <br />EAST LINE OF WEST � \ <br />R 907.1 HEIGHT= 0 TO 1.5 -FT <br />b" GATE VALVE &BOX GUTTER (TYP) SANMH2 6"X6" TEE 330 FT &SOUTH LINE SIDEWALK (TYP) <br />CONCRETE RIM = 907 N b" GATE VALVE =897.8 ZONED: PUD (PLANNED UNIT DEVELOPMENT) <br />DRIVEWAY IN E8 &BOX I OF NORTH 365.46 FT ZONED: R-4 (HIGH DENSITY RESIDENTIAL) I I O N <br />v 6 I ENTRANCE �N t� i OF NEI/4 OF SWl/4, , ADD <br />/" ` SEC. 8, T.301 R.23.RAE <br />ZONED: R-1 (SINGLE FAMILY RESIDENTIAL) CONNECT TO EXISTING I CONNECT TO EXISTING <br />WATERMAIN I SANITARY SEWER N N D V <br />b" GATE VALVE & BOX INV = 897.64 I �J V <br />Q� I NOT 8618 CURB & I i (FIELD VERIFY) C T E <br />GUTTER (TYP) I BITUMINOUS <br />PAVEMENT (TYP) BL OCK 5 BL OCK I <br />cc MATCH EXISTING G C <br />PAVEMENT, AND C <br />CURB & GUTTER <br />BITUMINOUS PAVEMENT SECTION <br />1�' BITUMINOUS WEARING <br />COURSE (MNDOT 2360 TYPE <br />S P W EA340B) <br />TACK COAT BETWEEN <br />BITUMINOUS COURSES <br />1�' BITUMINOUS BASE <br />COURSE (MNDOT 2360 TYPE <br />SPNWB330B) <br />b" MNDOT CLASS 5 <br />AGGREGATE BASE <br />APPROVED COMPACTED <br />SUBGRADE <br />NTS <br />2'-0' <br />1 <br />VALLEY GUTTER <br />CONCRETE <br />SEE PLANS FOR <br />8„ GUTTER SLOPE <br />2" MIN COMPACTED <br />CLASS 5 BELOW VALLEY <br />GUTTER <br />APPROVED COMPACTED <br />SUBGRADE <br />NTS <br />CONTRACTION AND EXPANSION JOINTS SHALL <br />BE CONSTRUCTED AS PER MNDOT SPEC. <br />2521.3C2 <br />CONCRETE SIDEWALK SECTION <br />ENGINEER WITH THE TOTAL DRAINAGE FIXTURE UNITS (DFUs) FOR THE INTERIOR 00) <br />O <br />PLUMBING TO VERIFY THE CORRECT SIZING AND SLOPE OF THE SANITARY SEWER LL <br />(0 � p <br />U <br />SERVICE <br />�V) <br />O <br />T <br />C <br />O <br />Q� <br />z <br />'j <br />W <br />O <br />N <br />UTILITY AND SURFACING NOTES: <br />0 <br />Q>_ <br />_ <br />Q z <br />N � <br />-5 <br />U <br />LQ <br />p <br />WATER AND SANITARY SEWER UTILITIES <br />O <br />o E <br />V <br />Q� <br />J <br />(D 0 <br />1. WATER MAIN AND ANY WATER SERVICE LINES SHALL BE PLACED AT A MINIMUM DEPTH <br />OC Z <br />O <br />OF 8 FEET BELOW FINISHED GRADE. <br />O <br />c9 <br />N = <br />O <br />� N � <br />2 <br />O-0 <br />2. IF CONFLICTS ARE DISCOVERED WHERE WATER MAIN CROSSES EXISTING SANITARY <br />OU <br />SEWER, SERVICE LINES, OR STORM SEWER, THE WATER MAIN SHALL BE RAISED OR <br />m <br />N <br />LOWERED APPROPRIATELY WHILE STILL MAINTAINING A MINIMUM DEPTH OF 8 FEET BELOW <br />U .O <br />FINISHED GRADE. <br />W <br />N'j <br />1 ''=40' <br />3. INSULATION SHALL BE PLACED AT ALL LOCATIONS WHERE STORM SEWER CROSSES <br />Q <br />SANITARY SEWER, WATER MAIN, OR ASSOCIATED SERVICES. INSULATION SHALL CONSISTC)} <br />OF AN 8 -FT X 8 -FT SQUARE OF 3" -THICK RIGID INSULATION. INSULATION SHALL BE PLACED <br />U <br />Q U N <br />BETWEEN THE STORM SEWER AND PIPE CROSSING WITH THE EDGES OF THE INSULATION <br />� .� � <br />PARALLEL TO THE PIPING AS MUCH AS POSSIBLE. <br />C) N <br />4. INSTALL SANITARY SEWER SERVICE LINE CLEANOUTS AS REQUIRED BY THE <br />MINNESOTA PLUMBING CODE <br />O <br />N <br />c <br />U > <br />5. SEE SHEET C3 FOR STORM SEWER GRADING, AND SHEET C2 FOR MISCELLANEOUS <br />U <br />O N <br />DETAILS RELATING TO THE PLACEMENT OF THE UTILITIES. <br />N <br />� <br />w <br />6. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF ALL EXISTING <br />__Q <br />UTILITIES PRIOR TO ANY CONSTRUCTION. <br />z <br />0 <br />7. PRIOR TO CONSTRUCTION OF SANITARY SEWER, AND ORDERING ASSOCIATED <br />MATERIALS, THE CONTRACTOR'S PLUMBING DESIGNER SHALL PROVIDE THE <br />ENGINEER WITH THE TOTAL DRAINAGE FIXTURE UNITS (DFUs) FOR THE INTERIOR 00) <br />O <br />PLUMBING TO VERIFY THE CORRECT SIZING AND SLOPE OF THE SANITARY SEWER LL <br />(0 � p <br />U <br />SERVICE <br />O r <br />O <br />z <br />z <br />w <br />c� i coo <br />ILL] <br />�' <br />C <br />W <br />N �- <br />z <br />OO N <br />z <br />M N <br />z <br />'j <br />W <br />O <br />N <br />W <br />LL L <br />_ <br />Q z <br />U <br />.2 Z (n <br />8. CONNECTION TO EXISTING UTILITY STRUCTURES SHALL BE DONE UNDER SUPERVISION ' ^ U <br />OF PUBLIC WORKS STAFF, AND SHALL BE COMPLETED BY CORE DRILLING INTO W V 0 <br />EXISTING STRUCTURE. a Q 4 <br />N <br />9. PUBLIC WORKS STAFF SHALL OPERATE ALL WATER MAIN GATE VALVES. CONTRACTOR <br />IS RESPONSIBLE TO NOTIFY AFFECTED PROPERTY OWNERS AT LEAST 24 -HOURS IN ADVANCE <br />OF WATER SUPPLY DISRUPTION. PUBLIC WORKS WILL PROVIDE A MAP OF AFFECTED <br />PROPERTIES FOR CONTRACTOR'S USE. <br />10. WET TAPPING OF EXISTING 12" CIP WATER MAIN SHALL BE DONE UNDER SUPERVISION <br />OF PUBLIC WORKS STAFF. CONTRACTOR SHALL COORDINATE THIS WORK AND PROVIDE <br />A MINIMUM OF 48 -HOURS NOTICE. OUTSIDE OF NORMAL WORKING HOURS (BEFORE <br />7:OOAM OR AFTER 3:OOPM) MAY RESULT IN ADDITIONAL STAFF TIME CHARGES. <br />11. CONNECTION TO EXISTING WATER MAIN SHALL BE DONE UNDER SUPERVISION OF <br />PUBLIC WORKS STAFF. CONNECTION SHALL BE COMPLETED BY WET TAP. <br />SURFACING <br />1. SUBGRADES SHALL BE SCARIFIED AND/OR COMPACTED AS NECESSARY TO ATTAIN <br />THE REQUIRED COMPACTION DESCRIBED IN THE GENERAL NOTES (SHEET Cl). <br />TEST ROLLING OF THE SUBGRADE SHALL BE OBSERVED BY A QUALIFIED GEOTECHNICAL <br />ENGINEER OR TECHNICIAN. LOCATIONS EXHIBITING EXCESSIVE RUTTING (PER MNDOT <br />SPEC. 21 1 1) SHALL BE REPAIRED TO THE SATISFACTION OF THE ENGINEER PRIOR TO <br />THE PLACEMENT OF AGGREGATE BASE. COMPACTION TESTING IN UTILITY TRENCHES <br />SHALL BE PERFORMED BY AN INDEPENDENT TESTING FIRM. <br />2. GRAVEL BASE COURSES SHALL BE ROLLED AND COMPACTED. TEST ROLLING OF THE <br />GRAVEL BASE SHALL BE OBSERVED BY A SOILS ENGINEER TO VERIFY STABILITY. <br />3. ALL EXISTING BITUMINOUS OR CONCRETE EDGES, WHICH WILL ABUT NEW BITUMINOUS <br />OR CONCRETE SURFACING SHALL BE SAWCUT TO OBTAIN A VERTICAL EDGE. <br />4. EXPANSION JOINTS SHALL BE PLACED AT ALL LOCATIONS WHERE NEW CONCRETE <br />ABUTS EXISTING CONCRETE, AND AT ALL LOCATIONS WHERE SEPARATE CONCRETE <br />POURS ABUT EACH OTHER. <br />5. SEE SHEET Cl FOR SPECIFICATIONS REGARDING THE CONSTRUCTION OF PAVEMENTS, <br />AND CURB AND GUTTER. <br />6. STREET PAVEMENT REMOVAL ASSOCIATED WITH NEW UTILITY CONNECTIONS SHALL BE <br />RECTANGULAR IN SHAPE, AND SAWCUT PLUMB. PAVEMENT PATCHING SECTION SHALL <br />MATCH THE EXISTING PAVEMENT SECTION, TO BE FIELD VERIFIED. <br />4" CONCRETE <br />(MNDOT CONCRETE MIX 3F52) <br />PARKING <br />LOT 4" CONCRETE <br />(MNDOT CONCRETE MIX 3F52) <br />1" CHAMFER <br />4" MNDOT 3149.262 SELECT <br />GRANULAR BORROWT4 <br />6', <br />APPROVED COMPACTED <br />SUBGRADE <br />4" MNDOT 3149.262 SELECT <br />GRANULAR BORROW <br />CONTRACTION AND EXPANSION JOINTS SHALL <br />BE CONSTRUCTED AS PER MNDOT SPEC. APPROVED COMPACTED <br />2521.3C2 SUBGRADE <br />NTS <br />THICKENED EDGE SIDEWALK <br />NTS <br />UTILITY & PAVING PLAN <br />Z <br />w <br />-a <br />ILL] <br />�' <br />C <br />W <br />N �- <br />z <br />N <br />C <br />O <br />O <br />C <br />_J <br />n <br />O <br />N <br />W <br />L <br />U <br />Q z <br />U <br />Q <br />Lu <br />V <br />> <br />r <br />(y) <br />CO <br />z <br />OC Z <br />O <br />c9 <br />N = <br />O <br />� N � <br />NUMBER: <br />Z <br />O <br />U <br />CIOLu <br />0 <br />cn w <br />Z <br />O o <br />V) <br />w O N �� <br />� z <br />w <br />z <br />O <br />n <br />Z <br />Q z <br />Ow <br />Lu <br />V <br />> <br />O < <br />z <br />UQ <br />PROJECT <br />NUMBER: <br />'> <br />0 <br />19007 <br />SCALE: <br />o_ <br />1 ''=40' <br />0 <br />C6 OF 6 <br />