Laserfiche WebLink
• (b) The inspector shall submit the original housing evaluation report <br /> to the seller. A duplicate shall be filed with the City within 10 <br /> calendar days after the evaluation has been made. <br /> Section 1306.07 Correction of Immediate Hazards. The following items, when <br /> determined by the inspector to be unsafe, shall be identified as immediate hazards in the <br /> evaluation report: <br /> Subd. 1. Heating Systems: <br /> (a) Burned out or rusted heat exchangers; <br /> (b) Burned out, rusted or plugged flues; <br /> (c) No vent; <br /> (d) Connection with unsafe gas supplies; or <br /> (e) Incapacity to adequately heat the living space. <br /> Subd. 2. Water Heaters: <br /> (a) Burned out, rusted, corroded or faulty heat exchangers; <br /> (b) Burned out, rusted, corroded or plugged flues; <br /> (c) No vents or inadequate venting; <br /> (d) Unsafe connection to gas supplies; or <br /> (e) Lack of temperature and pressure relief valves. <br /> Subd. 3. Electrical Systems: <br /> (a) Overloading or inadequate circuits or outlets; <br /> (b) Damaged or deteriorated electrical equipment; <br /> (c) Improperly tapped or spliced wiring; <br /> (d) Exposed uninsulated wires; <br /> (e) Temporary distribution systems; or <br /> • (f) Ungrounded systems. <br /> 5 <br />