Laserfiche WebLink
• Sampling <br /> • For each homogeneous type of suspected surfacing material,three to seven samples will <br /> be collected and analyzed, depending on the amount of material. <br /> • For each homogeneous type of suspect thermal system insulation, three samples will be <br /> collected and analyzed. <br /> • For each homogeneous type of suspect miscellaneous material (ceiling tile, floor tile, <br /> sheetrock,plaster, etc.), one to three samples will be collected and analyzed. <br /> Analysis <br /> • Bulk samples will be analyzed by IEA's laboratory which is accredited by NVLAP, and <br /> participates in several quality assurance programs. <br /> • Analysis will be conducted by Polarized Light Microscopy (PLM)backed by dispersion <br /> staining techniques. <br /> • All samples and records will be archived for a minimum of three years. <br /> PROPOSED COST <br /> The fee for this inspection profile reflects survey and sampling time, analysis of the data and all <br /> documentation and reporting. <br /> • SURVEY,REPORT AND LABORATORY SERVICES: $968.00 <br /> Please contact IEA if you have any questions regarding this service or the proposed cost indicated <br /> above. <br /> • <br />