Laserfiche WebLink
CHAPTER <br /> PLUMBING FACILITIES AND <br /> FIXTURE REQUIREMENTS <br /> SECTION 501 503.3 Location of employee toilet facilities.Toilet facilities <br /> GENERAL shall have access from within the employees' working area. <br /> The required toilet facilities shall be located not more than one <br /> 501.1 Scope.The provisions of this chapter shall govern the story above or below the employees'working area and the path <br /> minimum plumbing systems,facilities and plumbing fixtures of travel to such facilities shall not exceed a distance of 500 feet <br /> to be provided. (152 m).Employee facilities shall either be separate facilities <br /> 501.2 Responsibility.The owner of the structure shall provide or combined employee and public facilities. <br /> and maintain such plumbing facilities and plumbing fixtures in Exception: Facilities that are required for employees in <br /> compliance with these requirements.A person shall not occupy storage structures or kiosks,which are located in adjacent <br /> as owner-occupant or permit another person to occupy any structures under the same ownership,lease or control,shall <br /> structure or premises which does not comply with the require- not exceed a travel distance of 500 feet(152 m) from the <br /> ments of this chapter. employees'regular working area to the facilities. <br /> 503.4 Floor surface.In other than dwelling units,every toilet <br /> [P]SECTION 502 room floor shall be maintained to be a smooth, hard, <br /> REQUIRED FACILITIES nonabsorbent surface to permit such floor to be easily kept in a <br /> clean and sanitary condition. <br /> 502.1 Dwelling units. Every dwelling unit shall contain its <br /> own bathtub or shower,lavatory,water closet and kitchen sink <br /> which shall be maintained in a sanitary, safe working condi- [P] SECTION 504 <br /> tion.The lavatory shall be placed in the same room as the water PLUMBING SYSTEMS AND FIXTURES <br /> closet or located in close proximity to the door leading directly 504.1 General. All plumbing fixtures shall be properly <br /> into the room in which such water closet is located.A kitchen installed and maintained in working order, and shall be kept <br /> sink shall not be used as a substitute for the required lavatory. free from obstructions,leaks and defects and be capable of per- <br /> 502.2 Rooming houses.At least one water closet,lavatory and forming the function for which such plumbing fixtures are <br /> bathtub or shower shall be supplied for each four rooming designed.All plumbing fixtures shall be maintained in a safe, <br /> units. sanitary and functional condition. <br /> 502.3 Hotels.Where private water closets,lavatories and baths 504.2 Fixture clearances.Plumbing fixtures shall have ade- <br /> are not provided,one water closet,one lavatory and one bath- quate clearances for usage and cleaning. <br /> tub or shower having access from a public hallway shall be pro- 504.3 Plumbing system hazards. Where it is found that a <br /> vided for each ten occupants. plumbing system in a structure constitutes a hazard to the occu- <br /> 502.4 Employees'facilities.A minimum of one water closet, pants or the structure by reason of inadequate service,inade- <br /> one lavatory and one drinking facility shall be available to quate venting, cross connection, backsiphonage, improper <br /> employees. installation,deterioration or damage or for similar reasons,the <br /> code official shall require the defects to be corrected to elimi- <br /> 502.4.1 Drinking facilities. Drinking facilities shall be a nate the hazard. <br /> drinking fountain,water cooler,bottled water cooler or dis- <br /> posable cups next to a sink or water dispenser. Drinking <br /> facilities shall not be located in toilet rooms or bathrooms. SECTION 505 <br /> WATER SYSTEM <br /> [P]SECTION 503 505.1 General.Every sink,lavatory,bathtub or shower,drink- <br /> TOILET ROOMS ing fountain, water closet or other plumbing fixture shall be <br /> properly connected to either a public water system or to an <br /> 503.1 Privacy.Toilet rooms and bathrooms shall provide pri- approved private water system. All kitchen sinks, lavatories, <br /> vacy and shall not constitute the only passageway to a hall or laundry facilities,bathtubs and showers shall be supplied with <br /> other space, or to the exterior. A door and interior locking hot or tempered and cold running water in accordance with the <br /> device shall be provided for all common or shared bathrooms International Plumbing Code. <br /> and toilet rooms in a multiple dwelling. <br /> [P] 505.2 Contamination. The water supply shall be main- <br /> 503.2 Location. Toilet rooms and bathrooms serving hotel tained free from contamination,and all water inlets for plumb- <br /> units,rooming units or dormitory units or housekeeping units, ing fixtures shall be located above the flood-level rim of the <br /> shall have access by traversing not more than one flight of stairs fixture.Shampoo basin faucets,janitor sink faucets and other <br /> and shall have access from a common hall or passageway. hose bibs or faucets to which hoses are attached and left in <br /> 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE® 15 <br />