My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PL PACKET 03182008
StAnthony
>
Parks & Planning Commission
>
Planning Commission Packets
>
2008
>
PL PACKET 03182008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2016 4:28:52 PM
Creation date
4/19/2016 4:28:34 PM
Metadata
Fields
SP Box #
33
SP Folder Name
PL PACKETS 2005-2011
SP Name
PL PACKET 03182008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CHAPTER 6 <br /> MECHANICAL AND ELECTRICAL REQUIREMENTS <br /> SECTION 601 Exceptions: <br /> GENERAL 1. Processing, storage and operation areas that require <br /> 601.1 Scope.The provisions of this chapter shall govern the cooling or special temperature conditions. <br /> minimum mechanical and electrical facilities and equipment to 2. Areas in which persons are primarily engaged in vig- <br /> be provided. orous physical activities. <br /> 601.2 Responsibility.The owner of the structure shall provide 602.5 Room temperature measurement.The required room <br /> and maintain mechanical and electrical facilities and equip- temperatures shall be measured 3 feet (914 mm) above the <br /> ment in compliance with these requirements. A person shall floor near the center of the room and 2 feet(610 mm)inward <br /> not occupy as owner-occupant or permit another person to from the center of each exterior wall. <br /> occupy any premises which does not comply with the require- <br /> ments of this chapter. <br /> SECTION 603 <br /> SECTION 602 MECHANICAL EQUIPMENT <br /> HEATING FACILITIES 603.1 Mechanical appliances. All mechanical appliances, <br /> 602.1 Facilities required.Heating facilities shall be provided fireplaces, solid fuel-burning appliances, cooking appliances <br /> in structures as required by this section. and water heating appliances shall be properly installed and <br /> maintained in a safe working condition,and shall be capable of <br /> 602.2 Residential occupancies.Dwellings shall be provided performing the intended function. <br /> with heating facilities capable of maintaining a room tempera- <br /> ture of 68°F(20°C)in all habitable rooms,bathrooms and toilet 603.2 Removal of combustion products. All fuel-burning <br /> rooms based on the winter outdoor design temperature for the cand appliances shall be connected to an approved <br /> locality indicated in Appendix D of the International Plumbing chhimneyimney t or vent. <br /> Code.Cooking appliances shall not be used to provide space Exception:Fuel-burning equipment and appliances which <br /> heating to meet the requirements of this section. are labeled for unvented operation. <br /> Exception: In areas where the average monthly tempera- 603.3 Clearances. All required clearances to combustible <br /> ture is above 30°F(-1°C),a minimum temperature of 65°F materials shall be maintained. <br /> (18°C)shall be maintained. 603.4 Safety controls. All safety controls for fuel-burning <br /> 602.3 Heat supply.Every owner and operator of any building equipment shall be maintained in effective operation. <br /> who rents,leases or lets one or more dwelling units or sleeping 603.5 Combustion air.A supply of air for complete combus- <br /> units on terms,either expressed or implied,to furnish heat to <br /> tion of the fuel and for ventilation of the space containing the <br /> the occupants thereof shall supply heat during the period from <br /> fuel-burning equipment shall be provided for the fuel-burning <br /> [DATE]to[DATE]to maintain a temperature of not less than 68°F <br /> (20°C)in all habitable rooms,bathrooms,and toilet rooms. equipment. <br /> Exceptions: 603.6 Energy conservation devices. Devices intended to <br /> reduce fuel consumption by attachment to a fuel-burning appli- <br /> 1. When the outdoor temperature is below the winter ance,to the fuel supply line thereto,or to the vent outlet or vent <br /> outdoor design temperature for the locality,mainte- piping therefrom,shall not be installed unless labeled for such <br /> nance of the minimum room temperature shall not be purpose and the installation is specifically approved. <br /> required provided that the heating system is operating <br /> at its full design capacity.The winter outdoor design <br /> temperature for the locality shall be as indicated in SECTION 604 <br /> Appendix D of the International Plumbing Code. ELECTRICAL FACILITIES <br /> 2. In areas where the average monthly temperature is 604.1 Facilities required. Every occupied building shall be <br /> above 30°F (-1°C) a minimum temperature of 65°F provided with an electrical system in compliance with the <br /> (18°C)shall be maintained. requirements of this section and Section 605. <br /> 602.4 Occupiable work spaces. Indoor occupiable work 604.2 Service.The size and usage of appliances and equipment <br /> spaces shall be supplied with heat during the period from shall serve as a basis for determining the need for additional <br /> [DATE]to[DATE]to maintain a temperature of not less than 65°F facilities in accordance with the ICC Electrical Code.Dwelling <br /> (18°C)during the period the spaces are occupied. units shall be served by a three-wire, 120/240 volt, single- <br /> 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE® 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.