My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PL PACKET 09172019
StAnthony
>
Parks & Planning Commission
>
Planning Commission Packets
>
2019
>
PL PACKET 09172019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2019 10:51:25 AM
Creation date
9/11/2019 3:45:45 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Planning Commission Regular Meeting Minutes <br />August 20, 2019 <br />Page 6 <br /> <br /> 1 <br />A lighting plan has not been submitted for review. As a condition of Final PUD approval, a 2 <br />lighting plan should be submitted for review which demonstrates compliance with City 3 <br />requirements. 4 <br /> 5 <br />City Planner Grittman summarized the recommended Preliminary Plan PUD conditions: 6 <br /> 7 <br />1. An access easement shall be in place to accommodate the northerly access to the subject site. 8 <br />Proof of such access easement shall be provided to the City as a part of the original or 9 <br />amended PUD documentation. 10 <br />2. Access-related issues shall be subject to comment and recommendation by the City Engineer. 11 <br />3. As a part of the Final PUD Plan submission, a plan of the enclosed parking area shall be 12 <br />submitted for City review. 13 <br />4. The City finds that the proposed parking supply (and the deficit based on ordinance 14 <br />requirements) is adequate to serve the facility. 15 <br />5. Internal parking stalls which exhibit “bumper to bumper” or “bumper to wall” conditions 16 <br />should be increased from 18 – 19 feet in depth. 17 <br />6. Final PUD Plans demonstrate compliance with ADA parking supply requirements (for 18 <br />disabled persons). 19 <br />7. City Officials find the proposed five-story apartment building heights to be acceptable 20 <br />(within the context of the PUD). 21 <br />8. Sample floor plans be submitted which demonstrate compliance with applicable minimum 22 <br />floor area requirements of the Building Code. 23 <br />9. Details regarding the design of the clubhouse and pool building shall be submitted for City 24 <br />review. 25 <br />10. As a part of the Final Plan submission, the submitted landscape plan be expanded to specify 26 <br />plant varieties and sizes. 27 <br />11. Consideration be given to accentuating the primary entrance to the site via an intensified 28 <br />landscaping plan and other elements. Specifically, consideration be given to enhanced 29 <br />architectural features as well as provision of a landscape median near the eastern entrance to 30 <br />the site, between the garage entrance driveways and the sidewalk crossing to the east. 31 <br />12. As part of the Final PUD Plan submission, a lighting plan to be submitted for review which 32 <br />demonstrates compliance with City requirements. 33 <br />13. As part of the Final PUD Plan submission, a signage plan be submitted for review which 34 <br />demonstrates compliance with City requirements. 35 <br />14. The applicant provide information regarding trash handling activities. 36 <br />15. Issues related to grading, drainage and utilities shall be subject to comment and 37 <br />recommendation by the City Engineer. 38 <br />16. The applicant enter into a PUD agreement with the City and post all the necessary securities 39 <br />required by it. 40 <br />17. Consideration of comments by other City Staff. 41 <br /> 42 <br />City Planner Grittman stated this recommendation is based on a finding that the proposal, with 43 <br />the conditions cited, is consistent with the requirements for PUD consideration, with the long-44 <br />term objectives of the Silver Lake Village PUD, and with the recommendations and policies of 45 <br />the St. Anthony Comprehensive Plan. According to the EAW, the project is expected to generate 46
The URL can be used to link to this page
Your browser does not support the video tag.