Laserfiche WebLink
City Council Regular Meeting Minutes <br />January 26, 2021 <br />Page 5 <br />1 same ratings are the same distance was 68 to 75 decibels which was similar or slightly less than <br />2 what the street at Kenzie Terrace was. He explained he has information from the equipment <br />3 vendor about the blowers, the units that help dry the vehicle and also information about the <br />4 vacuum cleaners. He stated regarding the blowers, if he was standing fifty feet away from those <br />5 units there would be a decibel rating of 79 decibels with no barrier between him and blower <br />6 itself. The blowers will be in an enclosed building which the blowers inside of and are at the east <br />7 end of the building which is away from the condominium complex and there will be a door there <br />8 that will be closed almost one hundred percent of the time. His hope is that the door will only <br />9 open and close to allow vehicles out of the tunnel car wash. He did not anticipate leaving the <br />10 tunnel open unless for some reason the building needs to be aired out. He stated at a hundred <br />11 feet away the decibel level is 75. At the exit of the building, heading west the building is at least <br />12 125 feet with a driveway and setbacks with property line. There is likely 150 feet between the <br />13 residents and the actual area in which the noise will be coming out of the building. <br />14 <br />15 Mr. Archambault explained when it comes to the vacuum cleaners, the vacuum motors <br />16 themselves will be inside the building and will be inside the enclosed equipment room. The <br />17 noise will be very minimal when the door opens and closes because there will be a completely <br />18 enclosed room where the vacuum blowers are inside of. He stated the rating of noise there at <br />19 fifty feet are 75 decibels. <br />20 <br />21 Councilmember Randle asked if there was an environmental impact study done for air quality or <br />22 was one even required. Mr. Archambault indicated he has not had an environmental impact <br />23 study done but have done phase one environmental of the soil and the property itself and have <br />24 done soil boring and testing of the sample bores but in terms of air quality and things of that <br />25 nature to his knowledge it is not required of them nor has one been completed. <br />26 <br />27 Mayor Stille asked with regard to the length of the facility, it can accommodate cars while being <br />28 washed and also dried and wondered if the door will be closed during that time or will cars <br />29 continually be going through which would leave the door open. Mr. Archambault explained <br />30 because this is an express tunnel car wash the blowers or dryers will be set back probably fifteen <br />31 feet from the exit of the building so the vehicle will go completely through the dryer prior to <br />32 reaching the door itself. <br />33 <br />34 Mayor Stille asked if it was safe to say that the door will be shut until the drying cycle is done <br />35 and then open up to allow the car to go out then will close again. Mr. Archambault indicated that <br />36 was correct. <br />37 <br />38 Mayor Stille asked what the anticipation is with soundproofing within. He explained he has been <br />39 reading that some of the motors can be built such that there are boxes around them with extra <br />40 insulation, maybe even insulation on the walls, etc. to help with acoustics and sound and he <br />41 wondered how that effects equipment quality. Mr. Archambault indicated he would try to <br />42 answer that but Mr. John Grotkin, RJ Ryan and the project manager would be able to speak to <br />43 some of the soundproofing of the building itself. He explained when it comes to soundproofing <br />44 of equipment, very similar to what he has in his current facility right now, there is a car wash bay <br />45 in the back of that building with a pressure washer and around it they built a sound deadening <br />46 box because the building itself is built of cinder blocks and sound travels through the building <br />