<br />Saint Anthony Village Lowry Grove Redevelopment TIF District Building Report <br />LHB Project No. 170752 Page 2 of 2 Parcel B Building 2, Park Office and Barbershop <br />3. Fire Protection/Adequate Egress <br />a. There are no code required smoke detectors in the building. <br />b. There is no code required emergency notification system in the building. <br />c. There is no code required emergency lighting in the building. <br />d. There is no code required building sprinkler system installed. <br /> <br />4. Layout and Condition of Interior Partitions/Materials <br />a. Interior walls should be repaired/repainted. <br />b. Carpeting is stained. <br />c. Carpeting is bulging, causing an impediment to emergency egress, which is contrary to code. <br /> <br />5. Exterior Construction <br />a. Windows have failed and are allowing for water intrusion, contrary to code. <br />b. Exterior steel door is rusting and should be repainted. <br />c. Vinyl siding is damaged. <br />d. Roofing material should be replaced to prevent water intrusion, per code. <br />e. Metal stairs off north exit do not comply with code. <br /> <br /> <br />Description of Code Deficiencies <br /> <br />1. Thresholds are not ADA code compliant. <br />2. Glass doors should have code required 10-inch kick plates. <br />3. There is no ADA code compliant route into the building. <br />4. There is no ADA code compliant route between levels. <br />5. Restroom sink hardware should be replaced with ADA code compliant fittings. <br />6. Door hardware is not ADA code compliant. <br />7. Basement stairs do not have code required handrails. <br />8. Electrical wiring is not code compliant for a commercial building. <br />9. HVAC system does not comply with mechanical/building code. <br />10. Code required smoke detectors should be installed. <br />11. Code required emergency notification system should be installed. <br />12. Code required emergency lighting should be installed. <br />13. Code required building sprinkler system should be installed. <br />14. Carpet is bulging, creating an impediment to emergency egress, which is contrary to code. <br />15. Windows should be replaced to prevent water intrusion per code. <br />16. Roofing material should be replaced to prevent water intrusion, per code. <br />17. Metal stairs on north side of building should be modified to comply with code. <br /> <br /> <br />Overview of Deficiencies <br />This building appears to have originally been a convenience store and was converted to a barber shop and the <br />trailer park office. The basement was used as a storm shelter that was not ADA accessible. The exterior <br />windows have failed along with the roofing material. There are holes in the vinyl siding. The exterior metal <br />doors are rusting and should be repainted. The foundation walls are effervescing and should be <br />resealed/repainted. The interior walls should be repainted, and the carpet should be replaced. <br /> <br /> <br /> <br />O:\17Proj\170752\400 Design\406 Reports\Building Reports\2501 Lowry Ave NE - Park Office and Barber Shop\170752 2501 Lowry Ave N Park <br />Office and Barbershop Building Report.docx <br />43