My WebLink
|
Help
|
About
|
Sign Out
Home
2013.12.19 PC Packet
Hugo
>
Community Development
>
Planning & Zoning
>
Planning Commission
>
Planning Agendas/Packets
>
2013 PC Packets
>
2013.12.19 PC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2015 1:12:47 PM
Creation date
2/20/2015 1:11:56 PM
Metadata
Fields
Template:
Commissions
Meeting Date
12/19/2013
Document Type
Agenda/Packets
Commission Name
Planning
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Resolution 2014 - <br />Page 3 a =_ <br />a. For portions of the building that are over 35 feet in height: <br />i. 50 feet from all exterior property lines, except the areas that abut a <br />public street right- of -way. <br />b. 30 feet from exterior property lines. <br />c. 30 feet from all public right of way. <br />d. 10 feet from all interior property lines. <br />11. The applicant must comply with the following, prior to Final Plat and Final PUD Plan <br />application: <br />Architectural and Design standards <br />a. All buildings shall meet the requirements in the Multi -Family Design Guidelines <br />b. All building elevations shall receive nearly equal treatment and visual qualities. <br />c. The trash enclosure shall be screened with materials consistent with the building <br />material and shall be reviewed and approved by staff. <br />d. The developer shall submit a design palette for the entire project for City review <br />and approval. The palette shall include colors for awnings, siding, shakes, <br />shutters, shingles, brick and stone. Building colors and materials shall be <br />cohesive for all buildings within the PUD. <br />e. All ground -level mechanical units shall be low profile and located to the side or <br />rear of the building and shall be screened from view of adjacent properties. <br />f. The internal roof drainage system that shall be integrated into the building design <br />and shall be reviewed and approved by staff <br />Landscaping and Lighting <br />g. The landscape plan shall be revised to include the number, size, and type of trees <br />and shrubs required by Section 90-181 of the ordinance. The final plans must be <br />submitted for review and approval by staff. <br />h. The landscape plan shall be revised to be planned together and not separate for <br />each phase. <br />i. There shall be a landscape buffer between the senior housing facility and the <br />residential homes. The landscaping shall be of a sufficient height and size to <br />adequately provide a buffer. This shall be reviewed and approved by staff. <br />j. Exterior lighting shall be consistent throughout the development. All lighting <br />shall be shielded to prevent glare and light trespass, as required by Section 90-239 <br />
The URL can be used to link to this page
Your browser does not support the video tag.