Laserfiche WebLink
13620 Fenway Blvd. North, Hugo, MN 55038 <br />RSP PROJECT NUMBER: <br />CLIENT PROJECT NUMBER <br />6263.303.48 <br />001 <br />LOCATION MAP <br />�tti •�i 11 •�� + I <br />ov <br />' � R <br />_. <br />x , "AM <br />f 411kl� r <br />+�OF 0 IF <br />* 4JIAV <br />t •�i rr f � � r � I y� _, w <br />Si <br />KEY PLAN <br />010 5U 100ft <br />DRAWING SYMBOLS <br />0 0 <br />COLUMN OR GRID <br />LINE - NEW <br />�I <br />COLUMN OR GRID <br />LINE - EXISTING <br />MATCH LINE MATCH LINE <br />EE <br />T.O. FOOTING <br />EL. = 96'-0" ELEVATION / <br />LEVELTAG <br />EL. = 100'-0" SPOT ELEVATION <br />C:\Revit Projects\A16_Xcel Gas Train ing_HEngle.rvt <br />7/7/2017 11:53:50 AM <br />spm <br />P, -%ft- <br />x <br />X <br />X <br />REVISION <br />REFERENCE <br />PARTITION TAG <br />,� 2 VIEW <br />DRAWING TITLE <br />1/8" =1'-0"NAME <br />NORTH ARROW <br />PROJECT TEAM <br />ARCHITECT <br />TENANT CONTACT <br />RSP Architects, Ltd. <br />XCEL ENERGY <br />1220 Marshall Street NE <br />13620 Fenway Ave. North <br />Minneapolis, MN 55413 <br />Hugo, MN 55038 <br />Phone: 612/677-7100 <br />Phone: 612/330-6473 Fax: <br />612/330-7856 <br />Fax: 612/677-7499 <br />Leigh Stoakes <br />Gordon Strom, Project Manager <br />Phone: Leigh.W.Stoakes@xcelenergy.com <br />Phone: 612/677-7344 <br />Email: Gordon.Strom@rsparch.com <br />CODE SUMMARY <br />PROJECT NAME <br />EXITING REQUIREMENTS: <br />Existing to remain, no changes <br />PROJECT DESCRIPTION: <br />Addition of new Gas Emergency Response Training Facility. <br />PLUMBING CALCULATION: <br />Existing to remain, no changes <br />APPLICABLE CODES: <br />2015 Minnesota Building Code <br />2012 International Building Code <br />2015 Minnesota Accessibility Code <br />2015 Minnesota Energy Code <br />2015 Minnesota Fire Code <br />2012 International Fire Code <br />2014 National Electrical Code <br />2015 Minnesota Plumbing Code <br />2015 Minnesota Mechanical and Fuel Gas Code <br />2012 International Mechanical Code <br />2015 Minnesota Conservation Code for Existing Buildings <br />OCCUPANCY: <br />Existing to remain, no changes <br />TYPE OF CONSTRUCTION: <br />Existing to remain, no changes <br />HEIGHT AND NUMBER OF STORIES: <br />Existing to remain, no changes <br />ALLOWABLE FLOOR AREA: <br />Existing to remain, no changes <br />FIRE RESISTIVE REQUIREMENTS: <br />Existing to remain, no changes <br />SHEET INDEX <br />DRAWINGS <br />ISSUES <br />ISSUE KEY: <br />1 ISSUED (WITH SIGNATURE) <br />2 REVISED AND RE -ISSUED (WITH SIGNATURE) <br />3 NOT FOR CONSTRUCTION - REFERENCE ONLY <br />4t <br />4 RE -ISSUED FROM A PRIOR BID PACK - NO REVISIONS <br />C <br />CU <br />Y <br />U <br />SHEET NO. <br />NAME <br />a <br />00 General <br />G000 COVER SHEET <br />X <br />02 CIVIL <br />C130 CIVIL GRADING, DRAINAGE, EROSION CONTROL & UTILITY PLAN <br />X <br />C131 CIVIL DETAILS PLAN <br />X <br />C180 PROPOSED LANDSCAPE PLAN <br />X <br />15 Architectural <br />A001 LOT 1, BLOCK 1 SITE PLAN <br />X <br />A002 SITE ENLARGEMENT <br />X <br />A003 GAS TRAINING SITE <br />X <br />A801 ENLARGED PLANS AND ELEVATIONS <br />X <br />A803 FUTURE TRAINING ADDITION - ENLARGED PLAN AND ELEVATIONS <br />X <br />1 <br />A101 ELEVATION TAG - <br />SINGLE VIEW <br />1 <br />A101 2 ELEVATION TAG - <br />MULTIPLE VIEW <br />11 1 <br />A101 DETAIL TAG <br />SIM <br />SIM <br />1 WALL SECTION <br />A101 TAG <br />SIM <br />1 BUILDING <br />A101 SECTION TAG <br />1 <br />SIM ENLARGED PLAN <br />OR DETAIL <br />REFERENCE <br />LOT 1 BLOCK 1 <br />ROY IOLITOR <br />SECONDADDITION <br />LOT 1 BLOCK 1 <br />ROS' MOLITOR <br />FIRSTADDITION <br />ROOM NAME 0 (ROOM NAME) <br />101 (ROOM NUMBER) <br />ROOM TAG <br />150 SF= (ROOM AREA) <br />XX <br />KEYNOTE <br />23 <br />WINDOW TAG <br />234 <br />EQUIPMENT TAG <br />0 UTLOT B <br />101 DOOR TAG <br />PNT1 (WALL FINISH) FINISH TAG - <br />VB1 (BASE FINISH) ALL SURFACES <br />CPT1 (FLOOR FINISH) <br />V61 FINISH TAG - <br />CPT1 WITH EXTENT <br />OF FINISH <br />CPT -01 CPT -02 FINISH <br />TRANSITION <br />DOCUMENT PACKAGE <br />ISSUED: June 12, 2017 <br />PACKAGE: Planning and Zoning Review <br />OVERALL REFERENCE PLAN <br />1" =100'-0" <br />RSP Architects <br />1220 Marshall Street NE 612.677.7100 <br />Minneapolis 612.677.7499 fax <br />Minnesota 55413-1036 www.rsparch.com <br />Consultants <br />Certification <br />I hereby certify that this plan, specification or report <br />was prepared by me or under my direct supervision and <br />that I am a duly licensed Architect under the laws of the <br />State of Minnesota. <br />Signature <br />Registration Number <br />Date <br />Project For <br />XCEL ENERGY <br />HUGO GAS <br />TRAINING <br />FACILITY <br />A <br /><,q,'V <br />c� <br />Project No. 6263.303.48 <br />Drawn By HE <br />Checked By GS <br />Date 06/12/2017 <br />NOTICE: The designs shown and described herein <br />including all technical drawings, graphics, and models <br />thereof, are proprietary and cannot be copied, duplicated <br />or commercially exploited, in whole or in part, without <br />express written permission of RSP Architects. These are <br />available for limited review and evaluation by clients, <br />consultants, contractors, government agencies, vendors <br />and office personnel only in accordance with this Notice. <br />© Copyright RSP Architects 2017. All rights reserved. <br />Revisions <br />No. I Date I Description I <br />COVER SHEET <br />