Laserfiche WebLink
1 2 3 1 4 <br />5 <br />r <br />7 <br />11 <br />TRANSPORTATION <br />FACILITY <br />MN <br />I_1 <br />P1 <br />B <br />C <br />N <br />E <br />F <br />97 <br />Eo <br />zo <br />M <br />2 <br />0? <br />M <br />2.1 <br />3 <br />ao <br />N <br />N <br />DOOR / OPENING SCHEDULE <br />DOOR NO <br />DOOR / OPENING <br />LABEL/ <br />RATING <br />OVERALL <br />WIDTH <br />FRAME <br />�GL <br />MOUNTING CONDITIONS <br />IHDW GRP <br />REMARKS <br />TYPE QTY WIDTH HEIGHT MATL <br />ITYPE IDEPTH IMATL <br />IHEAD IJAMB ISILL <br />A201 A <br />I F <br />12 <br />3'-0" <br />7'-0" <br />IHM <br />-- <br />6'-4" <br />F R 2 <br />-- <br />H M <br />-- <br />I D 1 /A4.801 <br />I D 1 /A4.801 <br />1 <br />121 <br />A201B <br />I F <br />11 <br />3'-0" <br />5'-8" <br />IHM <br />-- <br />3'-4" <br />FIR 1A <br />-- <br />IHM <br />-- <br />JAVA5.602 <br />C1/A5.602 <br />I D2/A5.504 <br />104 <br />I, 18'-1 " J, 4'-0" J, 15'-6" J, 4'-0" J, 15'-3" J, 4'-0" .17-2;1 <br />00 <br />zo <br />00 <br />zo <br />v <br />00 <br />zo <br />ROOM FINISH SCHEDULE <br />ROOM NO <br />I ROOM NAME <br />FLOOR <br />BASE <br />N WALL - TYP <br />E WALL <br />I <br />S WALL <br />I <br />W WALL <br />REMARKS <br />I MATL IFIN <br />MATL IFIN <br />MATL IFIN <br />MATL FIN <br />A200 MEZZ STORAGE GYP BD WIRE MESH PRECAST PRECAST <br />PARTITION <br />A201 MEZZ MECH CONC PRECAST GYP BD GYP BD PRECAST <br />DOOR SCHEDULE GENERAL NOTES <br />1. ALL DOORS ARE 1 3/4" THICK UNLESS OTHERWISE NOTED. <br />2. FOR FRAME DEPTH, ONLY EXCEPTIONS TO THE FOLLOWING TABLE ARE SCHEDULED: <br />GYPSUM BOARD PARTITIONS: THROAT OF FRAME TO MATCH WALL THICKNESS. <br />MASONRY PARTITIONS: <br />4" WALL: 3 3/4" FRAME <br />6" WALL: 5 3/4" FRAME <br />8" AND GREATER WALL: 7 3/4" FRAME <br />FRAME DEPTHS ARE SCHEDULED IN NOMINAL DIMENSIONS. SEE FRAME/ DOOR TYPES (DETAIL <br />SECTION 51000) FOR CORRESPONDING ACTUAL DIMENSIONS. <br />3. FOR GLASS TYPES, ONLY EXCEPTIONS TO THE FOLLOWING TABLE ARE SCHEDULED: <br />INTERIOR NON RATED: <br />CLEAR (SAFETY WHEN REQUIRED BY TABLE IN GLAZING SPECIFICATION.) <br />INTERIOR AND EXTERIOR RATED: <br />FIRE RATED <br />EXTERIOR NON -RATED: <br />CLEAR INSULATED (SAFETY INSULATED WHEN REQUIRED BY TABLE IN GLAZING SPECIFICATION.) <br />4. SEE SHEET AX.XX FOR FRAME TYPES. <br />5. SEE SHEET AXAX FOR DOOR TYPES. <br />6. AT DOOR SCHEDULE, LABEL DESIGNATION "45/20" INDICATES: <br />FOR ALL OPENINGS WITH SIDE LITES AND SCHEDULED TO BE RATED FOR 20 MINUTES, THE <br />DOOR AND ANY GLASS WITHIN THE DOOR IS TO BE RATED FOR 20 MINUTES; THE FRAME AND <br />ADJACENT SIDELITE(S) GLASS AND FRAME IS TO BE RATED FOR 45 MINUTES." <br />DOOR SCHEDULE REMARKS <br />1. SEE DETAIL 43018 FOR USE WITH ALTERNATE #1 <br />SEE DETAIL 54012 FOR USE WITH ALTERNATE #1 <br />2. <br />3. PROVIDE FIRE NUMBER AT EXTERIOR DOORS <br />DOOR NUMBER IN "_". <br />ROOM FINISH SCHEDULE GENERAL NOTES <br />1. SEE DETAILS OF CONSTRUCTION FOR ABBREVIATIONS <br />2. IF ALL WALLS IN ROOM HAVE THE SAME FINISH, THE "N <br />WALL-TYP" COLUMN WILL BE USED. <br />3. DISCREPANCIES BETWEEN THE ROOM FINISH <br />SCHEDULE AND DRAWINGS SHALL BE REPORTED TO <br />THE ARCHITECT FOR FINISH DETERMINATION. <br />4. PROVIDE VINYL BASE AT CASEWORK. <br />5. REFER TO MATERIAL FINISH/ COLOR SCHEDULE FOR <br />SPECIFIC FINISH TYPES AND COLORS. <br />6. FOR CEILING MATERIAL WHEN MORE THAN ONE <br />CEILING MATERIAL OCCURS THE CEILING FINISH IS <br />INDICATED THUS: "/". <br />7. PROVIDE GYPSUM BOARD SOFFIT ABOVE CASEWORK. <br />(SEE CASEWORK ELEVATIONS AND REFLECTED <br />CEILING PLANS.) <br />ROOM FINISH SCHEDULE REMARKS <br />1. PROVIDE CERAMIC TILE TO A HEIGHT OF 5'-0" WITH EPDXY PAINT ABOVE, EPT-6A <br />PAINT CEILING AND ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS, <br />2 VENTS, ETC, PT 8. <br />3. SEE INTERIOR ELEVATION FOR WALL GRAPHIC. <br />SLOPE CONC. FLOOR TOWARDS FLOOR DRAINS. SEE PLANS FOR FLOOR SLOPING <br />4. INFORMATION. <br />5. EPDXY PAINT TO 7'-2" HIGH. <br />PLAN GENERAL NOTES <br />1. ALL PLAN DIMENSIONS ARE NOMINAL TO FACE OF <br />WALL. WALL THICKNESSES ARE SHOWN NOMINAL, SEE <br />WALL TYPES FOR ACTUAL THICKNESS. <br />2. ALL GYP. WALLS ARE TO BE 5 INCHES THICK UNLESS <br />OTHERWISE NOTED. <br />3. ALL CONCRETE BLOCK WALLS ARE TO BE 8 INCHES <br />THICK UNLESS OTHERWISE NOTED. <br />4. COORDINATE SIZE AND LOCATION OF ALL DUCT AND <br />SHAFT OPENINGS IN WALLS AND FLOORS W/ MECH. <br />AND ELEC. PROVIDE ALL REQUIRED LINTELS FOR <br />OPENINGS. SEE LINTEL SCHEDULE. <br />5. FIELD VERIFY ALL MILLWORK OPENINGS. <br />6. SET FLOOR DRAINS 3/4" BELOW FINISHED CONCRETE <br />FLOORS UNLESS OTHERWISE NOTED. PROVIDE <br />CONSISTENT SLOPE FROM WALL TO DRAIN BY <br />SLOPING CONCRETE, MIN. 1/4" PER FOOT. <br />7. VERIFY LOCATION, SIZE AND QUANTITY OF ALL <br />MECHANICAL AND ELECTRICAL EQUIPMENT PADS. <br />8. ALL DOOR/SIDELITE OPENINGS TO BEGIN 4" FROM <br />ADJACENT WALL UNLESS OTHERWISE NOTED. <br />9. ALL GYP. WALLS ARE CENTERED ON GRID UNLESS <br />OTHERWISE NOTED. <br />10. FIRE RATED WALLS ARE INDICATED ON CODE PLANS. <br />FLOOR PLAN KEY NOTES: <br />ODOOR ACTUATOR; SEE DETAILS FOR MOUNTING <br />HEIGHTS. <br />OBOLLARDS AT INTERIOR AND EXTERIOR OF OVER <br />HEAD DOORS, TYP - SEE DETAIL B1/A6.101. <br />OTUB SINK - SEE MECHANICAL <br />OCORNER GUARD <br />OEMERGENCY EYE WASH. SEE MECH. <br />ONOT USED <br />O7 FIRE ALARM ANUNCIATOR PANEL, FLUSH MOUNTED <br />IN GYP WALL, SEE ELEC <br />Og LOCATION OF SEMI -RECESSED DEFIBRILLATOR <br />CABINET (NIC) <br />OLOCATION OF STACKED WASHER AND <br />DRYER (NIC) <br />10 MECHANICAL EQUIPMENT PAD. SEE MECH FOR MORE <br />DETAIL. <br />11 STEEL PIPE RAIL / RAILING PAINTED <br />12 ACCESSIBLE BENCH BY LOCKER <br />13 VEHICLE LIFT, COORDINATE WITH SUPPLIER FOR <br />EXACT DIMENSIONS <br />14 TRENCH DRAIN, SEE DETAIL F3/A4.706; SEE ALSO <br />MECH <br />15 8'-0" TALL WIRE MESH PARTITION. COORDINATE WITH <br />ROOF DECK AND STRUCTURE ABOVE <br />16 TV MOUNT; SEE INTERIOR ELEVATION FOR HEIGHT. <br />17 GRATED FLOOR SINK, SEE DETAIL E5/A4.706 ; SEE <br />ALSO MECH <br />18 FLOOR DRAIN. COORDINATE WITH MECHANICAL <br />19 MECHANICAL EQUIPMENT CURB. SEE MECH FOR <br />MORE DETAIL. <br />20 TACK BOARD; SEE E7/A4.706 . <br />21 TRASH AREA ENCLOSURE, SEE CIVIL <br />22 CARD READER, SEE ELEC FOR LOCATION <br />23 REFER TO MECH FOR LOCATION OF FLAMMABLE <br />WASTE TRAP <br />24 REFER TO MECH FOR LOCATION OF SUMP PIT <br />25 PIT FOR FUTURE LIFT WITH TEMPORARY CONCRETE <br />SLAB ON SAND INFILL, SEE STRUCTURAL, SEE <br />DETAIL D5/A5.502 <br />26 STEEL COLUMN, SEE STRUCTURAL <br />13411 Fenway Blvd N <br />Hugo,MN 55038 <br />INDEPENDENT SCHOOL <br />DISTRICT #624 <br />4855 Bloom Avenue <br />White Bear Lake, MN 55110 <br />WOLD ARCHITECTS <br />AND ENGINEERS <br />332 Minnesota Street, Suite W2000 <br />Saint Paul, MN 55101 <br />woldae.com 1 651 227 7773 <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />ARCHITECT <br />under the law�f the State of Minnesota <br />w i <br />/i.► ie/tea �E <br />/lV A, t Jam_ <br />Paul Aplikowski <br />License Number: 42737 Date 8/14/2020 <br />Revisions <br />Description <br />Date <br />Aug, 25, 2020 <br />Num <br />Addendum #1 <br />1 <br />Addendum #3 <br />September 4, 2020 <br />2 <br />Addendum #5 <br />September 11 <br />3 <br />Comm: 202063 <br />Date: 8/14/2020 <br />Drawn: HAK <br />Check: EBL North <br />MEZZ LEVEL <br />FLOOR PLAN <br />BAS E M EZZ <br />1/8" = 1'-0" <br />Scale: As indicated <br />A2m02 <br />