<br /> <br /> <br />Geotechnical Report <br />2021 Street Improvements <br />Hugo, Minnesota <br />WSB Project No. 015887-000 Page 6 <br />4. ENGINEERING ANALYSIS AND RECOMMENDATIONS <br /> <br />4.1 Discussion <br />No information was provided to us regarding density tests or excavation observations for the existing fills <br />encountered at the boring locations. Generally, fills that are not documented are recommended for <br />removal and replacement with an engineered fill. However, our borings did not encounter deleterious <br />materials within or beneath the fill. It appears that these fills were placed as utility backfill or for the <br />pavement subgrade area. Based on the soil borings and our understanding of these fills, it is our opinion <br />that the risk of construction upon them is relatively low. <br /> <br />Organic soils and vegetated root zones are not suitable for structural support and should be removed <br />from the roadway fill areas. <br /> <br />Based on the results of our borings, the glacially deposited soils generally appear capable of supporting <br />the pavements and utilities. <br /> <br />It is our opinion that groundwater could be encountered by excavations at this site and could affect <br />construction of utilities. Dewatering may be required during utility placement. <br /> <br />4.2 Backfill and Fill Selection and Compaction <br />The on-site non-organic soils may be reused as backfill and fill provided, they are moisture conditioned <br />and can be compacted to their specified densities. Wet soils that are excavated would need to be dried <br />before reuse as an engineered fill. We recommend use of a minimum of 2 feet of clean coarse sand with <br />less than 50 percent passing the #40 sieve and less than 5 percent passing the #200 sieve when <br />backfilling the bottom of a wet excavation. <br /> <br />Backfills with cobbles larger than six inches (6”) should not be placed within 3 feet of grading grade or in <br />contact with utilities. We recommend that clayey soils be moisture conditioned to within +/-2 percent of <br />the optimum moisture content as determined from their standard Proctor tests (ASTM D-698). Fill should <br />be spread in lifts of 8 to 12 inches, depending on the size and type of compaction equipment used. <br /> <br />Table 4 provides the recommended compaction levels. <br /> <br />Table 4: Recommended Level of Compaction for Backfill and Fill <br />Area Percent of Standard Proctor <br />Maximum Dry Density <br />Pavement: Within 3 feet of bottom of aggregate base <br /> Within 3-foot radius of vertical utility structure <br />100 <br />Pavement: Greater than 3 feet below aggregate base 95 <br />Utility Trench 95 <br />Landscaping (non-structural) 90 <br /> <br />4.3 Pavement Subgrade Preparation and Stability <br />The soils at the bottom of the excavation should be prepared in accordance with MnDOT Specification <br />2112, Subgrade Preparation. If the subgrade preparation operations encounter unstable soils, we <br />recommend removing these unsuitable materials and replacing them with Select Grading Material <br />(MnDOT 2105.1.A.6). If the on-site soils cannot be moisture conditioned and compacted as <br />recommended, additional measures, such as placement of additional sand subbase or a section of <br />coarse breaker run aggregate, can be completed to provide a firm base for subsequent fill placement. <br /> <br />Before placement of the sand subbase, the final subgrade should have proper stability within three <br />vertical feet of grading grade (grade which contacts the bottom of the aggregate base). This will generally