Laserfiche WebLink
1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />CODELEGEND <br />8 <br />MN <br />A <br />B <br />C <br />h7 <br />E <br />F <br />REQUIRED WIDTH: <br />113x0.2=23" <br />ACTUAL WIDTH: 32" <br />113 <br />UILDIN <br />E <br />IIB <br />REQUIRED WIDTH: <br />111 x 0.15 = 17" <br />ACTUAL WIDTH: 32" <br />1 HR FIRE RATED <br />CONSTRUCTION; EXTEND <br />4' BEYOND FIRE WALL PER <br />ll 7nR F 1 1 <br />ACTUAL WIDTH: 64" <br />REQUIRED WIDTH: <br />213x0.15=32" <br />ACTUAL WIDTH: 32" <br />REQUIRED WIDTH: (A OCCUPANCY) <br />104 104x0.2=21" <br />ACTUAL WIDTH: 32" <br />REQUIRED WIDTH: (A OCCUPANCY) <br />�100 100x0.2=20" <br />tc ACTUAL WIDTH: 32" <br />I <br />I <br />BUILDING #3 <br />1 HR FIRE RATED <br />CONSTRUCTION; EXTEND <br />4' BEYOND FIRE WALL PER <br />IBC 706.5.1.1 <br />REQUIRED WIDTH: (A OCCUPANCY) <br />100x0.2=20" <br />ACTUAL WIDTH: 32" <br />JREQUIRED W@TH: (A OCCUPANCY) <br />114x0.2=23" <br />ACTUAL WIDTH: 96" <br />REQUIRED WIDTH: (E OCCUPANCY) <br />296x0.15=45" <br />ACTUAL WIDTH: 96" <br />AREA 'A' <br />AREA'B' <br />REQUIRED WIDTH: <br />283 283 x 0.15 = 43" <br />- - / CTUAL WIDTH: 64" <br />I <br />— — — — — 0 <br />W I <br />REQUIRED WIDTH: <br />283 283 x 0.15 = 43" <br />ACTUAL WIDTH: 64" <br />I <br />I <br />®J <br />UILDING #1 <br />E <br />1113 <br />MAIN PATH OF EGRESS <br />EXIT LOAD <br />OCCUPANTLOAD <br />OCCUPANT FACTOR <br />00 N N <br />N M <br />NEW 2 HOUR FIRE WALL <br />(AREA SEPARATIONS: 706.1, HORIZONTAL EXITS: 1025.1) <br />DOOR OPENINGS: <br />90 MIN.; < 25% LENGTH OF WALL <br />GLAZING: <br />90 MIN. 100 SQ. IN. MAX <br />DUCTWORK: <br />90 MIN. FIRE DAMPER <br />NEW 2 HOUR FIRE BARRIER <br />(SHAFT ENCLOSURES: 707.3.1, HORIZ EXITS: 1025.1 /707 /711, OCCUPANCY SEPARATIONS: <br />508.4, INTERIOR EXIT STAIRWAY/ EXIT ACCESS STAIRWAY: 1022.2, /707 /711) <br />DOOR OPENINGS: <br />90 MIN. <br />GLAZING: <br />100 SQ IN MAX, 33" MAX HT, 10" MAX WIDTH <br />DUCTWORK: <br />90 MIN. FIRE DAMPER <br />90 MIN FIRE/ SMOKE DAMPER (AT SHAFT ENCLOSURES) <br />CONSTRUCTION CAPABLE OF RESISTING THE PASSAGE OF SMOKE <br />(509.4.2 / MN PR-01) <br />GAPS < 1 1/2": <br />MINERAL WOOL OR FIRE SAFING <br />GAPS > 1 1/2": <br />SMOKE SEALANT <br />DOOR CLOSERS REQ'D: <br />(SMOKE GASKETING NOT REQUIRED) <br />TRANSFER DUCTS: <br />SMOKE DAMPER <br />STANDARD DUCTS: <br />SMOKE / FIRE DAMPER NOT REQUIRED <br />1 HOUR SMOKE BARRIER (OCCUPANCY 1-3, 408.6 / 709.3) <br />OPENINGS: DOORS 20 MIN., WINDOWS 45 MIN. <br />GLAZING: 1296 SQ IN, 54" MAX WIDTH/ HEIGHT OR MAX SIZE TESTED <br />DUCTWORK: SMOKE DAMPER <br />O O O O O O O O <br />O O O O O O O O O <br />O O O O O O O O <br />00 O O O O O O O <br />O O O O O O O O <br />NEW ZERO RATED CORRIDOR <br />(1018.1 WITH SPRINKLER SYSTEM) <br />OPENINGS: 0 MIN. <br />GLAZING: 0 MIN. <br />DUCTWORK: CORRIDOR CANNOT BE USED AS SUPPLY, RETURN, EXHAUST, <br />RELIEF OR VENTILATION AIR DUCTS. <br />NOTE: RETURN AIR PLENUMS ARE ALLOWED. (1018.5.1) <br />\ t9., <br />\ <br />\ <br />\ \ CLASSROOM <br />CLASSROOM\ CLASSROOM <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ I <br />\ I <br />�J \ <br />\ I <br />\ \ SMALL <br />\ GROUP <br />\ I <br />------ - - - - -- <br />\ I <br />\ \ <br />265 SF <br />STAFF 95' \ <br />OFFICE 81 SF \ TOTAL AREA = 706 SIF <br />------------------- - - - - -- L <br />r J <br />74'-9" COMMON PATH <br />I � <br />--------- -- <br />J <br />r-- ---� or <br />I I I I <br />I 1 1 I I <br />v 72" 129 SF <br />SMALL I 114 SF I I - - - - - - - — 71 <br />GROUP <br />I <br />I I <br />I I <br />I I <br />I I <br />I <br />CALMING SENSORY L - <br />CLASSROOM ROOM ROOM <br />I <br />I <br />I <br />I <br />SPECIAL <br />ED/ <br />INTERVENTION <br />I <br />I I I I I I II II I II I I I <br />I I I I I I II II I II I I I <br />I I I I I I I I I I I I I <br />- ---- <br />I <br />I I I I I I 1 1 <br />dl <br />\V __1 - <br />L) A <br />I I I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />L- - - - - - - - - - - - I <br />CLASSROOM <br />4' <br />SMALL <br />3ROUP <br />ELEC <br />STORAGE <br />T <br />r�1 <br />< <br />< <br />< <br />< <br />0 <br />< <br />Y <br />4 <br />S <br />< <br />< <br />NEW ELEMENTARY <br />SCHOOL <br />15198 Forest Boulevard <br />Hugo, Minnesota 55038 <br />INDEPENDENT SCHOOL <br />DISTRICT #624 <br />4855 Bloom Ave <br />White Bear Lake, Minnesota 55110 <br />WOLD ARCHITECTS <br />AND ENGINEERS <br />332 Minnesota Street, Suite W2000 <br />Saint Paul, MN 55101 <br />woldae.com 1 651 227 7773 <br />KRAUS-ANDERSON® <br />501 South Eighth Street <br />Minneapolis, MN 55404 <br />krausanderson.com 1 612 332 7281 <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />ARCHITECT <br />under the laws of the State of <br />MINNESOTA <br />low .e <br />..- <br />%J L% r <br />License Paul Aplikowski <br />Number: 42737 Date 11/20/2020 <br />Revisions <br />Description Date Num <br />Comm: 192237 <br />Date: 11/20/2020 <br />Drawn: THE <br />Check: Ell North <br />CODE PLAN - <br />MAIN LEVEL <br />CODE PLAN - MAIN LEVEL <br />1/16" = 1'-0" <br />0 12' 24' <br />ENLARGED STUDIO CODE PLAN, TYPICAL <br />1/8" = 1'-01, <br />0 6' 12' <br />Scale: As indicated <br />A0m101 <br />