<br />BUILDING # 1
<br />CODE ANALYSIS (IBC 2018)
<br />FULLY SPRINKLERED
<br />A 1. OCCUPANCY CLASSIFICATIONS
<br />A. SECTION 303, ASSEMBLY:
<br />B. SECTION 304, BUSINESS:
<br />C. SECTION 305, EDUCATIONAL:
<br />2. INCIDENTAL USE AREAS
<br />SECTION 302
<br />GROUPS A-2 (FOR EXITING & PLUMBING FIXTURES ONLY)
<br />GROUP B (ACCESSORY USE <10 % )
<br />GROUP E
<br />TABLE 509
<br />MN
<br />3. MIXED OCCUPANCIES SECTION 508
<br />A. SEPARATIONS N/A
<br />B. NOTES:
<br />1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES
<br />OR THE MAIN OCCUPANCY PER 508.2.4.
<br />2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYING
<br />MORE THAN 10 % OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESS
<br />THAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3)
<br />3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATING
<br />AREAS DO NOT REQUIRE A SEPARATION.
<br />0
<br />B
<br />C
<br />4. CONSTRUCTION TYPE / FIRE RESISTANCE TABLE 6011602
<br />A. TYPE II-B
<br />BUILDING ELEMENT
<br />FIRE RESISTANCE
<br />STRUCTURAL FRAME
<br />0 HR
<br />EXT. BEARING WALLS
<br />0 HR (OR PER TABLE 602)
<br />INT. BEARING WALLS
<br />0 HR
<br />EXT. NON -BEARING WALLS
<br />0 => 30 FT.
<br />INT. NON -BEARING WALLS
<br />0 HR
<br />FLOOR CONSTRUCTION
<br />0 HR
<br />ROOF CONSTRUCTION
<br />0 HR
<br />VERTICAL SHAFTS AND
<br />1 HR < 4 STORIES; 2 HR = 4 STORIES +
<br />ELEVATOR SHAFTS (707.3.1 / 713.4)
<br />0 HR
<br />CORRIDORS (TABLE 1020 / 708)
<br />0 HR
<br />EXIT ACCESS STAIRWAY (1009.3)
<br />2 STORIES UNENCLOSED (EXCEPTION 1)
<br />INTERIOR EXIT STAIRWAY (1023)
<br />1 HR < 4 STORIES, 2 HR = 4 STORIES +
<br />5. GENERAL BUILDING HEIGHT AND AREA
<br />SECTION 504 / 506
<br />A. ALLOWABLE HEIGHT AND AREAS
<br />MOST RESTRICTIVE
<br />CONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER
<br />ALLOWABLE AREA NON -SEPARATED
<br />GROUP TABLE 601 TABLE 504.3 OF STORIES
<br />TABLE 506.2 OCCUPANCY 508.3
<br />E II B 75 FT 3 STORIES
<br />43,500 S.F.
<br />6. ALLOWABLE AREA MODIFICATIONS
<br />SECTION 506
<br />A. SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3
<br />GROUP E
<br />1. EQUATION 5-2 (506.2.3) :
<br />A(a) = {A(t) + [NS * I(f)] } * S(a)
<br />A(a) = { 43,500 + [ 14,500 *0.49 ] } * 2
<br />A(a) = 101,210 SF
<br />2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGE
<br />I(f) = [F/P - 0.25] * W/30
<br />I(f) = [913'-9"/1231'-7" - 0.25] * 30730
<br />I(f) = 0.49
<br />B. ACTUAL AREA
<br />GROUP MAIN LEVEL
<br />E 44,737 SF
<br />TOTALS: 69,113 SF
<br />UPPER LEVEL MEZZANINE **PENTHOUSE
<br />24,396 SF 4,441 SF
<br />NOTES: * THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGE
<br />OR A STORY OF THE ROOM IT SERVES PER 505.2.
<br />** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF,
<br />IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.
<br />7. MEANS OF EGRESS CHAPTER 10
<br />A. TRAVEL DISTANCES/ EXIT SYSTEMS
<br />1. COMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.
<br />(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)
<br />2. EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2
<br />D (TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)
<br />OCCUPANCY W/SPRINKLER
<br />A, E, F-1, M, R, S-1 250
<br />3. CORRIDORS 1020
<br />A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTS
<br />MINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.
<br />B. DEAD ENDS (1020.4):
<br />50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;
<br />OR
<br />LENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.
<br />E
<br />F
<br />BUILDING #2
<br />CODE ANALYSIS (IBC 2018)
<br />FULLY SPRINKLERED
<br />1. OCCUPANCY CLASSIFICATIONS SECTION 302
<br />A. SECTION 305, EDUCATIONAL: GROUP E
<br />2. INCIDENTAL USE AREAS TABLE 509
<br />BOILER ROOM (15 PSI OR 10 HP) 1 HR
<br />3. MIXED OCCUPANCIES SECTION 508
<br />A. SEPARATIONS N/A
<br />B. NOTES:
<br />1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES
<br />OR THE MAIN OCCUPANCY PER 508.2.4.
<br />2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYING
<br />MORE THAN 10 % OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESS
<br />THAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3)
<br />3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATING
<br />AREAS DO NOT REQUIRE A SEPARATION.
<br />4. CONSTRUCTION TYPE / FIRE RESISTANCE TABLE 601 / 602
<br />A. TYPE II-B
<br />BUILDING ELEMENT
<br />FIRE RESISTANCE
<br />STRUCTURAL FRAME
<br />0 HR
<br />EXT. BEARING WALLS
<br />0 HR (OR PER TABLE 602)
<br />INT. BEARING WALLS
<br />0 HR
<br />EXT. NON -BEARING WALLS
<br />0 => 30 FT.
<br />INT. NON -BEARING WALLS
<br />0 HR
<br />FLOOR CONSTRUCTION
<br />0 HR
<br />ROOF CONSTRUCTION
<br />0 HR
<br />VERTICAL SHAFTS AND
<br />1 HR <4 STORIES; 2 HR = 4 STORIES +
<br />ELEVATOR SHAFTS (707.3.1 / 713.4)
<br />0 HR
<br />CORRIDORS (TABLE 1020 / 708)
<br />0 HR
<br />EXIT ACCESS STAIRWAY (1009.3)
<br />2 STORIES UNENCLOSED (EXCEPTION 1)
<br />INTERIOR EXIT STAIRWAY (1023)
<br />1 HR <4 STORIES, 2 HR = 4 STORIES +
<br />5. GENERAL BUILDING HEIGHT AND AREA SECTION 5041506
<br />A. ALLOWABLE HEIGHT AND AREAS
<br />MOST RESTRICTIVE
<br />CONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER ALLOWABLE AREA NON -SEPARATED
<br />GROUP TABLE 601 TABLE 504.3 OF STORIES TABLE 506.2 OCCUPANCY 508.3
<br />E II B 75 FT 3 STORIES 43,500 S.F.
<br />6. ALLOWABLE AREA MODIFICATIONS
<br />A. SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3
<br />GROUP E
<br />1. EQUATION 5-2 (506.2.3) :
<br />A(a) = {A(t) + [NS * I(f)] } * S(a)
<br />A(a) = {43,500 + [ 14,500 * 0.47 ] } * 2
<br />A(a) = 100,630 SF
<br />2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGE
<br />I(f) = [F/P - 0.25] * W/30
<br />I(f) = [318'-6"/442'-5" - 0.25] * 30'/30
<br />I(f) = 0.47
<br />SECTION 506
<br />B. ACTUAL AREA
<br />GROUP MAIN LEVEL UPPER LEVEL MEZZANINE PENTHOUSE
<br />E 8,877 SF 8,877 SF
<br />TOTALS: 17,754 SF
<br />NOTES: * THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGE
<br />OR A STORY OF THE ROOM IT SERVES PER 505.2.
<br />** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF,
<br />IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.
<br />7. MEANS OF EGRESS CHAPTER 10
<br />A. TRAVEL DISTANCES/ EXIT SYSTEMS
<br />1. COMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.
<br />(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)
<br />2. EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2
<br />(TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)
<br />OCCUPANCY W/ SPRINKLER
<br />A, E, F-1, M, R, S-1 250
<br />3. CORRIDORS 1020
<br />A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTS
<br />MINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.
<br />B. DEAD ENDS (1020.4):
<br />50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;
<br />OR
<br />LENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.
<br />BUILDING #3
<br />CODE ANALYSIS (IBC 2018)
<br />FULLY SPRINKLERED
<br />1. OCCUPANCY CLASSIFICATIONS SECTION 302
<br />A. SECTION 303, ASSEMBLY: GROUPS A-3 (FOR EXITING & PLUMBING FIXTURES ONLY)
<br />B. SECTION 305, EDUCATIONAL: GROUP E
<br />2. INCIDENTAL USE AREAS TABLE 509
<br />BOILER ROOM (15 PSI OR 10 HP) 1 HR
<br />3. MIXED OCCUPANCIES SECTION 508
<br />A. SEPARATIONS N/A
<br />B. NOTES:
<br />1. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY OCCUPANCIES
<br />OR THE MAIN OCCUPANCY PER 508.2.4.
<br />2. PER 508.2, ACCESSORY OCCUPANCIES ARE DEFINED AS NOT OCCUPYING
<br />MORE THAN 10 % OF MAIN OCCUPANCY, SMALL ASSEMBLY AREAS OF LESS
<br />THAN 750 S.F. (303.1.2) OR ASSEMBLY AREAS ACCESSORY TO GROUP E.(303.1.3)
<br />3. COMMERCIAL KITCHENS AND DEDICATED RESTAURANT SEATING
<br />AREAS DO NOT REQUIRE A SEPARATION.
<br />4. CONSTRUCTION TYPE / FIRE RESISTANCE TABLE 601 / 602
<br />A. TYPE II-B
<br />BUILDING ELEMENT
<br />FIRE RESISTANCE
<br />STRUCTURAL FRAME
<br />0 HR
<br />EXT. BEARING WALLS
<br />0 HR (OR PER TABLE 602)
<br />INT. BEARING WALLS
<br />0 HR
<br />EXT. NON -BEARING WALLS
<br />0 => 30 FT.
<br />INT. NON -BEARING WALLS
<br />0 HR
<br />FLOOR CONSTRUCTION
<br />0 HR
<br />ROOF CONSTRUCTION
<br />0 HR
<br />VERTICAL SHAFTS AND
<br />1 HR < 4 STORIES; 2 HR = 4 STORIES +
<br />ELEVATOR SHAFTS (707.3.1 / 713.4)
<br />0 HR
<br />CORRIDORS (TABLE 1020 / 708)
<br />0 HR
<br />EXIT ACCESS STAIRWAY (1009.3)
<br />2 STORIES UNENCLOSED (EXCEPTION 1)
<br />INTERIOR EXIT STAIRWAY (1023)
<br />1 HR < 4 STORIES, 2 HR = 4 STORIES +
<br />5. GENERAL BUILDING HEIGHT AND AREA SECTION 504 / 506
<br />A. ALLOWABLE HEIGHT AND AREAS
<br />MOST RESTRICTIVE
<br />CONST TYPE ALLOWABLE HEIGHT ALLOWABLE NUMBER ALLOWABLE AREA NON -SEPARATED
<br />GROUP TABLE 601 TABLE 504.3 OF STORIES TABLE 506.2 OCCUPANCY 508.3
<br />E II B 75 FT 3 STORIES 43,500 S.F.
<br />6. ALLOWABLE AREA MODIFICATIONS
<br />A. SINGLE OCCUPANCY, MULTISTORY BUILDING 506.2.3
<br />GROUP E
<br />1. EQUATION 5-2 (506.2.3) :
<br />A(a) = {A(t) + [NS * I(f)] } * S(a)
<br />A(a) = { 43,500 + [ 14,500 * 0.33 ] } * 2
<br />A(a) = 96,570 SF
<br />2. EQUATION 5-5 (506.3.3) : AREA INCREASE DUE TO FRONTAGE
<br />I(f) = [F/P - 0.25] * W/30
<br />I(f) = [265'-2"/456'-7 - 0.25] * 30'/30
<br />I(f) = 0.33
<br />B. ACTUAL AREA
<br />GROUP MAIN LEVEL
<br />E 9,702 SF
<br />TOTALS: 10,557 SF
<br />UPPER LEVEL MEZZANINE
<br />855 SF
<br />SECTION 506
<br />**PENTHOUSE
<br />NOTES: * THE MEZZANINE IS LESS THAN 1/3 THE AREA OF THE ROOM IT SERVES AND IS NOT COUNTED SQUARE FOOTAGE
<br />OR A STORY OF THE ROOM IT SERVES PER 505.2.
<br />** THE ROOFTOP PENTHOUSE HOLDS MECHANICAL EQUIPMENT, DOES NOT EXTEND 18 FEET ABOVE ADJACENT ROOF,
<br />IS LESS THAN 1/3 THE AREA OF THE SUPPORTING ROOF AND IS NOT CONSIDERED AN ADDITIONAL STORY PER 1510.2.
<br />7. MEANS OF EGRESS CHAPTER 10
<br />A. TRAVEL DISTANCES/ EXIT SYSTEMS
<br />1. COMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1) = 75 FT.
<br />(TO A POINT WHERE OCCUPANT HAS TWO MEANS OF EGRESS.)
<br />2. EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2
<br />(TRAVEL DISTANCE TO AN EXIT OR A RATED EXIT SYSTEM.)
<br />OCCUPANCY W/SPRINKLER
<br />A, E, F-1, M, R, S-1 250
<br />3. CORRIDORS 1020
<br />A. MINIMUM WIDTH (TABLE 1020.2) = 44" OR 36" FOR LESS THAN 50 OCCUPANTS
<br />MINIMUM WIDTH 72" FOR GROUP E OVER 100 OCCUPANTS.
<br />B. DEAD ENDS (1020.4):
<br />50' IN ALL GROUPS EXCEPT A AND H WITH SPRINKLERED CONSTRUCTION;
<br />OR
<br />LENGTH = 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR.
<br />ALL BUILDINGS
<br />8. WALL AND CEILING FINISHES
<br />TABLE 803.13
<br />SPRINKLERED
<br />ROOMSAND
<br />GROUP CORRIDORS
<br />ENCLOSED SPACES
<br />A-1,A-2 B/A
<br />C/B
<br />A-3, A-4, A-5 B/ A
<br />C/ C
<br />B,E,M C/B
<br />C/C
<br />9. RECYCLING SPACE
<br />MN CODE 1303.15
<br />TABLE 1-A
<br />USE
<br />FACTOR
<br />S.F./ USE
<br />S.F. REQUIRED
<br />AUDITORIUMS, STADIUMS, GYMNASIUMS
<br />0.001
<br />6560
<br />7
<br />(EXCLUDES PLAYING AREAS,
<br />COURTS AND FIELDS)
<br />CONFERENCE ROOMS
<br />0.0025
<br />2741
<br />7
<br />DINING ROOMS
<br />0.003
<br />3822
<br />12
<br />CLASSROOMS
<br />0.002
<br />28242
<br />57
<br />KITCHEN, COMMERCIAL
<br />0.003
<br />1371
<br />5
<br />LIBRARIES (INC. ASSOC. INCIDENTAL AREAS)
<br />0.002
<br />3132
<br />7
<br />MECHANICAL EQUIP ROOM
<br />0.001
<br />5747
<br />6
<br />OFFICES
<br />0.0025
<br />12015
<br />31
<br />STORAGE AND STOCK ROOMS
<br />0.0025
<br />2063
<br />6
<br />ALL OTHERS
<br />0.0025
<br />4002
<br />11
<br />TOTAL RECYCLING SPACE REQUIRED
<br />149 S.F.
<br />10a. DAYTIME PLUMBING FIXTURE COUNT
<br />TABLE 2902.1
<br />NOTE: DAYTIME OCCUPANCY IS BASED ON STUDENT/STAFF CAPACITY AND EXCLUDES ASSEMBLY
<br />SPACES
<br />A. "E" OCCUPANCY (DAY) STUDENTS / STAFF ACTUAL CAPACITY OF 820 PLUS 10
<br />1. OCCUPANTS MEN
<br />WOMEN
<br />TOTAL
<br />451
<br />451
<br />902
<br />DRINKING
<br />SERVICE
<br />2. FIXTURE RATIO WC URINAL LAV
<br />WC
<br />LAV
<br />FOUNTAINS
<br />SINK
<br />1:50 <2/3 OF WC 1:50
<br />1:50
<br />1:50
<br />1:100
<br />1
<br />3. FIXTURES REQUIRED 10 NONE 10
<br />10
<br />10
<br />10
<br />1
<br />4. ACTUAL FIXTURES 20* 0 22
<br />21
<br />22
<br />20
<br />3
<br />* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.
<br />10b. EVENING PLUMBING FIXTURE COUNT TABLE 2902.1
<br />NOTE: EVENING OCCUPANCY ASSUMES CONCURRENT EVENTS IN CAFETERIA & GYMNASIUM
<br />A. "A-2" OCCUPANCY (CAFETERIA)
<br />1. OCCUPANTS
<br />MEN
<br />WOMEN
<br />TOTAL
<br />111
<br />111
<br />222
<br />DRINKING
<br />SERVICE
<br />2. FIXTURE RATIO
<br />WC
<br />URINAL LAV WC LAV
<br />FOUNTAINS
<br />SINK
<br />1:75
<br /><2/3 OF WC 1:200 1:75 1:200
<br />1:500
<br />1
<br />3. FIXTURES REQUIRED
<br />2
<br />NONE 1 2 1
<br />1
<br />1
<br />B. "A-3" OCCUPANCY (GYMNASIUM)
<br />1. OCCUPANTS
<br />MEN
<br />WOMEN
<br />TOTAL
<br />300
<br />300
<br />600
<br />DRINKING
<br />SERVICE
<br />2. FIXTURE RATIO
<br />WC URINAL LAV
<br />WC LAV
<br />FOUNTAINS
<br />SINK
<br />1:125 <2/3 OF WC 1:200
<br />1:65 1:200
<br />1:500
<br />1
<br />3. FIXTURES REQUIRED
<br />3 NONE 2
<br />5 2
<br />2
<br />1
<br />C. TOTAL EVENING FIXTURES REQ'D 5* 0 3 7 3 3 1
<br />* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.
<br />D. ACTUAL EVENING FIXTURES 6* 0 8 8 9 8 2
<br />* 0 URINALS ARE BEING SUBSTITUTED FOR 0 MEN'S WATER CLOSETS.
<br />12. ENERGY CODE
<br />THE ENERGY CODE USED FOR THIS PROJECT IS
<br />IECC
<br />THE BUILDING IS IN ZONE # 6A
<br />NEW ELEMENTARY
<br />SCHOOL
<br />15198 Forest Boulevard
<br />Hugo, Minnesota 55038
<br />INDEPENDENT SCHOOL
<br />DISTRICT #624
<br />4855 Bloom Ave
<br />White Bear Lake, Minnesota 55110
<br />WOLD ARCHITECTS
<br />AND ENGINEERS
<br />332 Minnesota Street, Suite W2000
<br />Saint Paul, MN 55101
<br />woldae.com 1 651 227 7773
<br />KRAUS-ANDERSON,
<br />501 South Eighth Street
<br />Minneapolis, MN 55404
<br />krausanderson.com 1 612 332 7281
<br />EFFECTIVE CODE REFERENCES
<br />2020 MINNESOTA STATE BUILDING CODE
<br />(MSBC), CHAPTER 1305, WHICH ADOPTS AND
<br />AMENDS THE 2018 INTERNATIONAL BUILDING
<br />CODE (IBC)
<br />2020 MINNESOTA STATE MECHANICAL AND
<br />FUEL GAS CODE, CHAPTER 1346
<br />2020 NATIONAL ELECTRICAL CODE (NEC)
<br />2015 MINNESOTA STATE PLUMBING CODE,
<br />CHAPTER 4714
<br />2020 MINNESOTA STATE FIRE CODE, WHICH
<br />ADOPTS AND AMENDS THE 2018
<br />INTERNATIONAL FIRE CODE
<br />2020 MINNESOTA COMMERCIAL ENERGY CODE,
<br />CHAPTERS 1322 & 1323
<br />2020 MINNESOTA ACCESSIBILITY CODE,
<br />CHAPTER 1341
<br />2020 MINNESOTA ELEVATOR AND RELATED
<br />DEVICES CODE, CHAPTER 1307
<br />I hereby certify that this plan, specification or report was prepared by
<br />me or under my direct supervision and that I am a duly Licensed
<br />ARCHITECT
<br />under the laws of the State of
<br />MINNESOTA
<br />Aw t
<br />is i ii i All P
<br />License Paul Aplikowski
<br />Number: 42737 Date 11/20/2020
<br />Revisions
<br />Description Date Num
<br />Comm: 192237
<br />Date: 11 /20/2020
<br />Drawn: THE
<br />Check: EBL North
<br />CODE ANALYSIS
<br />Scale: 1/16" = V-0"