Laserfiche WebLink
GENERAL NOTES -PLUMBINGA. COORDINATE INSTALLATION OF ALL NEW PIPING WITH STRUCTURAL ELEMENTS AND ALL NEW DUCTWORK, CEILINGS, LIGHTS, ETC.B. COORDINATE WITH ARCHITECTURAL DRAWINGS ON REQUIREMENTS FOR ALL CHASES, WALLS, FURROUTS, ETC. REQUIRED FOR DUCTWORK AND PIPING.C. PROVIDE ISOLATION VALVES AT EVERY BRANCH TAKE-OFF FROM MAINS. LOCATE VALVES NEXT TO MAIN WITH HANDLES EASILY ACCESSIBLE.D. REFER TO RISER DIAGRAMS AND DETAILS FOR ADDITIONAL VALVES AND SIZES.E. REFER TO PLUMBING FIXTURE ROUGH-IN AND FLOOR DRAIN SCHEDULES FOR PIPE SIZES TO INDIVIDUAL FIXTURES.F. PITCH ALL UNDERFLOOR SANITARY PIPING AT 1/4" PER FOOT (MIN.) UNLESS NOTED OTHERWISE.G. PITCH ALL RAINWATER PIPING AT 1/8" PER FOOT (MIN.) UNLESS NOTED OTHERWISE.H. PROVIDE ALL EXPOSED PIPES WITH A FINISH SUITABLE AND READY FOR FIELD PAINTING.I. INSTALL ALL EQUIPMENT AND HORIZONTAL PIPING AS HIGH AS POSSIBLE UP TIGHT TO STRUCTURE.J. IDENTIFY ANY INSULATION, FITTINGS, TILE, PLASTER, ETC., WHICH MAY CONTAIN ASBESTOS AND NOTIFY OWNER. OWNER SHALL REMOVE ASBESTOS UNDER A SEPARATE CONTRACT.K. FIELD VERIFY ALL EXISTING CONDITIONS, PIPING, DUCT LOCATIONS, SIZES, ETC.L. REMOVE AND REINSTALL ALL EXISTING CEILING SYSTEMS REQUIRED FOR NEW DUCT SYSTEMS UNLESS NOTED OTHERWISE ON ARCHITECTURAL DRAWINGS.M. REMOVE AND REROUTE ANY EXISTING PIPING REQUIRED FOR INSTALLATION OF NEW EQUIPMENT, DUCTS, PIPES, DIFFUSERS, LIGHTS, ETC. UNLESS NOTED OTHERWISE ON ARCHITECTURAL DRAWINGS.N. EXISTING MECHANICAL DRAWINGS ARE AVAILABLE FOR CONTRACTOR'S REVIEW AND INSPECTION. CALL TO MAKE ARRANGEMENTS.O. PROVIDE CLEANOUT AT CONNECTIONS TO ALL EXISTING WASTE, VENT, AND RAINWATER SYSTEMS, EVERY 50' FOR SANITARY AND RAINWATER PIPES LESS THAN 3", EVERY 100' FOR SANITARY AND RAINWATER PIPES 3" AND LARGER, AND AT THE BASE OF ALL SANITARY AND RAINWATER RISERS.XSINKXRW3456789101112GFEDx10x9.2P5ORWXORWXRWVVXRWORWXRW5"83/4"1 1/2"3/4"83XSINK33/4"1 1/2"1"81 1/4"3/4"1"86" RW(3400 SF)5"84" XORW UP TO XORD(3400 SF)19XRD2110XRD74" ORW(1200 SF)4" XORW UP TO XORD(1200 SF)4" XORW UP (800 SF)1124"8(2) XUR3(2) XWC3XWB3(4) XWC3XLAV3XWC3XMOP33456789101112EDx10x9.2P5XSINKP55"3/4"1 1/2"3/4"5"ORWXRWXRW883181754VV1 1/2"3/4"1 1/2"1/2"86710FEDCBA12345678AMNNorthCheck:Drawn:Date:Comm:License Number:I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensedunder the laws of the State of Minnesota.Scale:DateProfessional Engineer3/22/20224855 Bloom AveWhite Bear Lake, MN 551103/22/2022 1:29:55 PMBIM 360://Oneka Elementary School Addition and Renovation/M21_Oneka ES_Central_kweinzierl.rvt1/8" = 1'-0"INDEPENDENT SCHOOLDISTRICT #624ONEKAELEMENTARYSCHOOL ADDITIONAND RENOVATIONM2.01aMAIN LEVELPLUMBING PLAN -AREA A4888 HERITAGE PKWY NORTHHUGO, MN 55038SITE PLAN APPLICATION -NOT FORCONSTRUCTIONKEWKEW3/22/2022R20-4013.000KEITH E. WEINZIERL41638KEYNOTES1 PROVIDE CO AT CONNECTION TO EXISTING WASTE AND/OR VENTSYSTEM.2 CAP PIPE(S) HERE.3 PLUMBING FIXTURE SHALL REMAIN.4 CONNECT NEW SINK ROUGH-IN TO XSINK ROUGH-IN.5 WALL SAWCUT AND PATCHED BY OTHERS. REFER TOARCHITECTURAL DRAWINGS.6 FCO.7 PROVIDE WCO IN SAN UNDER PLUMBING FIXTURE.8 PIPE SHALL REMAIN AS EXISTING.9 CONNECT NEW ORWL TO XORD.10 CONNECT NEW VENT TO XVTR.1/8" = 1'-0"MAIN LEVEL PLUMBING PLAN - AREA A BASE BID11/8" = 1'-0"MAIN LEVEL PLUMBING PLAN - AREA A ALTERNATE 12RevisionsDescription Date Num