Laserfiche WebLink
STORM WATER POLLUTION PREVENTION PLAN NARRATIVE - PAGE 1 OF 2 <br />ACREAGE SUMMARY <br />AREA ACRES <br />PROPERTY 24.8 <br />DISTURBED 21.3 <br />IMP. PRE-CONSTRUCTION 1.06 <br />IMP. POST-CONSTRUCTION 10.06 <br />NEW IMP.9.0 <br />PERVIOUS AT COMPLETION 14.74 <br />PROJECT DESCRIPTION/LOCATION <br />ONEKA PRAIRIE IS LOCATED IN THE CITY OF HUGO IN WASHINGTON COUNTY, BOUNDED BY EMPRESS AVE <br />N, EVERTON AVE N AND 165TH ST N. THE PROPERTY IS LOCATED IN RICE CREEK WATERSHED, AND <br />ENCOMPASSES 24.8 ACRES. <br />THE PLANNED SCOPE OF THE PROJECT INCLUDES: <br />·THE INSTALLATION OF EROSION CONTROL MEASURES AS REQUIRED FOR THE MASS GRADING OF <br />THE SITE FOR THE CONSTRUCTION OF NEW ROADS, AND HOUSES. <br />·GRADING AS REQUIRED FOR THE INSTALLATION OF THE NEW HOUSES, SIDEWALKS, ROADS, AND <br />STORMWATER PONDS. <br />·THE CONSTRUCTION OF 4 STORMWATER PONDS. <br />·INSTALLATION OF SANITARY SEWER, WATERMAIN, AND STORM SEWER. <br />·PLACEMENT OF CONCRETE AS REQUIRED TO ESTABLISH CURB, GUTTER, AND SIDEWALKS <br />THROUGHOUT THE SITE. <br />·CONSTRUCTION OF NEW ROADS. <br />RECEIVING WATERS <br />THESE WATERS ARE LOCATED WITHIN ONE MILE (AERIAL RADIUS) OF THE PROJECT LIMITS AND RECEIVE <br />RUNOFF FROM THE PROJECT SITE. DUE TO THE PROXIMITY OF THE RECEIVING WATERS, THE BMPS <br />DESCRIBED IN APPENDIX A OF THE NPDES PERMIT MAY APPLY TO ALL AREAS OF THE SITE. <br />HARDWOOD CREEK HAS AN APPROVED TMDL FOR DISSOLVED OXYGEN AND FISHES BIO, NOT FOR <br />CONSTRUCTION RELATED ACTIVITIES <br />SOIL TYPES <br />SOIL TYPES TYPICALLY FOUND ON THIS PROJECT ARE SANDY LEAN CLAY AND CLAYEY LEAN SAND <br />(GENERALLY TYPE B SOILS), WITH LESSER AMOUNTS OF POORLY GRADED SAND WITH SILT AND SILTY <br />SAND (GENERALLY TYPE C SOILS), PER GEOTECHNICAL REPORT DATED 06/06/2022 GEOTECHNICAL <br />REPORT IS TO BE KEPT ON SITE AS PART OF THE SWPPP AND IS TO BE MADE AVAILABLE UPON REQUEST. <br />LONG TERM MAINTENANCE AND OPERATION <br />SOUTHWIND HOLDINGS HAS ENTERED INTO A MAINTENANCE AGREEMENT WITH THE CITY OF HUGO THAT <br />IDENTIFIES THE AGENCY THAT IS RESPONSIBLE FOR ONGOING MAINTENANCE, AND HOW RESPONSIBILITY <br />WILL BE TRANSFERRED TO OTHER AGENTS, OR PRIVATELY MAINTAINED. <br />PROJECT PERSONNEL AND TRAINING <br />THIS SWPPP WAS PREPARED BY PERSONNEL THAT ARE CERTIFIED IN THE DESIGN OF CONSTRUCTION <br />SWPPP. COPIES OF THE CERTIFICATIONS ARE ON FILE WITH THE ENGINEER. <br />PROVIDE A CERTIFIED EROSION CONTROL SUPERVISOR IN GOOD STANDING WHO IS KNOWLEDGEABLE <br />AND EXPERIENCED IN THE APPLICATION OF EROSION PREVENTION AND SEDIMENT CONTROL BEST <br />MANAGEMENT PRACTICES. THE EROSION CONTROL SUPERVISOR WILL WORK WITH THE PROJECT <br />ENGINEER / SWPPP DESIGNER TO OVERSEE THE IMPLEMENTATION OF THE SWPPP AND THE <br />INSTALLATION, INSPECTION, AND MAINTENANCE OF THE EROSION PREVENTION AND SEDIMENT CONTROL <br />BMPS BEFORE, DURING, AND AFTER CONSTRUCTION UNTIL THE NOTICE OF TERMINATION (NOT) HAS BEEN <br />FILED WITH THE MPCA. PROVIDE PROOF OF CERTIFICATION AT THE PRECONSTRUCTION MEETING. WORK <br />WILL NOT BE ALLOWED TO COMMENCE UNTIL PROOF OF CERTIFICATION HAS BEEN PROVIDED TO THE <br />PROJECT ENGINEER. <br />PROVIDE AT LEAST ONE CERTIFIED INSTALLER FOR EACH CONTRACTOR OR SUBCONTRACTOR THAT <br />INSTALLS THE PRODUCTS LISTED IN SPECIFICATION SECTION 2573.3.A.2 CERTIFIED INSTALLERS. PROVIDE <br />PROOF OF CERTIFICATION AT THE PRECONSTRUCTION MEETING. WORK WILL NOT BE ALLOWED TO <br />COMMENCE UNTIL PROOF OF CERTIFICATION HAS BEEN PROVIDED TO THE PROJECT ENGINEER. <br />CHAIN OF RESPONSIBILITY <br />THE OWNER AND CONTRACTOR ARE CO-PERMITTEES FOR THE NATIONAL POLLUTANT DISCHARGE <br />ELIMINATION SYSTEM (NPDES) CONSTRUCTION PERMIT. THE CONTRACTOR IS RESPONSIBLE TO COMPLY <br />WITH ALL ASPECTS OF THE NPDES CONSTRUCTION PERMIT AT ALL TIMES UNTIL THE NOTICE OF <br />TERMINATION (NOT) HAS BEEN FILED WITH THE MPCA THE CONTRACTOR WILL DEVELOP A CHAIN OF <br />COMMAND WITH ALL OPERATORS ON THE SITE TO ENSURE THAT THE SWPPP WILL BE IMPLEMENTED AND <br />STAY IN EFFECT UNTIL THE CONSTRUCTION PROJECT IS COMPLETE, THE ENTIRE SITE HAS UNDERGONE <br />FINAL STABILIZATION, AND A NOTICE OF TERMINATION (NOT) HAS BEEN SUBMITTED TO THE MPCA. <br />PROJECT CONTACTS <br />THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTATION OF THE SWPPP AND INSTALLATION, <br />INSPECTION, AND MAINTENANCE OF THE EROSION PREVENTION AND SEDIMENT CONTROL BMPS BEFORE, <br />DURING, AND AFTER CONSTRUCTION UNTIL THE NOTICE OF TERMINATION (NOT) HAS BEEN FILED. <br />*CERTIFIED FOR DESIGN OF CONSTRUCTION SWPPP BY UNIVERSITY OF MINNESOTA, EXPIRES 5/31/23 <br />MPCA DUTY OFFICER 24 HOUR EMERGENCY NOTIFICATION: <br />651-649-5451 OR 800-422-0798 <br />SITE INSPECTION AND MAINTENANCE <br />CONTRACTOR SHALL PROVIDE NAME, CONTACT INFO, AND TRAINING DOCUMENTATION FOR THE PERSON <br />RESPONSIBLE FOR SWPPP IMPLEMENTATION AND INSPECTION/MAINTENANCE OF BMPS. <br />INSPECT THE ENTIRE CONSTRUCTION SITE A MINIMUM OF ONCE EVERY SEVEN DAYS DURING ACTIVE <br />CONSTRUCTION AND WITHIN 24 HOURS AFTER A RAINFALL EVENT GREATER THAN 0.5 INCHES WITHIN A 24 <br />HOUR TIME FRAME. INSPECT ALL TEMPORARY AND PERMANENT WATER QUALITY MANAGEMENT, EROSION <br />PREVENTION AND SEDIMENT CONTROL BMPS UNTIL THE SITE HAS UNDERGONE FINAL STABILIZATION AND <br />THE N.O.T. HAS BEEN SUBMITTED. INSPECT SURFACE WATER INCLUDING DRAINAGE DITCHES FOR SIGNS <br />OF EROSION AND SEDIMENT DEPOSITION. INSPECT CONSTRUCTION SITE VEHICLE EXIT LOCATIONS FOR <br />EVIDENCE OF TRACKING ONTO PAVED SURFACES. INSPECT SURROUNDING PROPERTIES FOR EVIDENCE <br />OF OFF SITE SEDIMENT ACCUMULATION. <br />RECORD ALL INSPECTIONS AND MAINTENANCE ACTIVITIES IN WRITING WITHIN 24 HOURS. SUBMIT <br />INSPECTION REPORTS IN A FORMAT THAT IS ACCEPTABLE TO THE PROJECT ENGINEER. <br />FOR PROJECTS THAT DISCHARGE TO PROHIBITED WATERS, CONDUCT ROUTINE SITE INSPECTIONS AT A <br />MINIMUM OF ONCE EVERY 72 HOURS (3 DAYS). <br />INCLUDE THE FOLLOWING IN THE RECORDS OF EACH INSPECTION AND MAINTENANCE ACTIVITY: <br />A.DATE AND TIME OF INSPECTIONS <br />B.NAME OF PERSONS CONDUCTING INSPECTIONS <br />C.FINDINGS OF INSPECTIONS, INCLUDING RECOMMENDATIONS FOR CORRECTIVE ACTIONS <br />D.CORRECTIVE ACTION TAKEN, INCLUDING DATES, TIMES, AND PARTY COMPLETING MAINTENANCE <br />ACTIVITIES <br />E.DATE AND AMOUNT OF ALL RAINFALL EVENTS GREATER THAN 0.5 INCH IN 24 HOURS <br />F.DOCUMENTS AND CHANGES MADE TO THE SWPPP <br />REPLACE, REPAIR OR SUPPLEMENT ALL NONFUNCTIONAL BMPS BY IN THE TIME PROVIDED BELOW: <br />A.REPAIR, REPLACE, OR SUPPLEMENT PERIMETER CONTROL DEVICES WHEN IT BECOMES <br />NONFUNCTIONAL OR SEDIMENT REACHES 12 THE HEIGHT OF THE DEVICE. COMPLETE REPAIRS BY <br />B.THE END OF THE NEXT BUSINESS DAY FOLLOWING DISCOVERY. <br />C.REPAIR OR REPLACE INLET PROTECTION DEVICES WHEN THEY BECOME NONFUNCTIONAL OR <br />SEDIMENT REACHES 12 THE HEIGHT AND/OR DEPTH OF THE DEVICE. COMPLETE REPAIRS BY THE <br />END OF THE NEXT BUSINESS DAY FOLLOWING DISCOVER. <br />D.DRAIN AND REMOVE SEDIMENT FROM TEMPORARY AND PERMANENT SEDIMENT BASINS ONCE THE <br />SEDIMENT HAS REACHED 12 THE STORAGE VOLUME. COMPLETE WORK WITHIN 72 HOURS OF <br />DISCOVERY. <br />E.REMOVE ALL DELTAS AND SEDIMENT DEPOSITED IN SURFACE WATER INCLUDING DRAINAGE WAYS, <br />CATCH BASINS, AND OTHER DRAINAGE SYSTEMS. RESTABILIZED ANY AREAS THAT ARE DISTURBED <br />BY SEDIMENT REMOVAL OPERATION. SEDIMENT REMOVAL AND STABILIZATION MUST BE <br />COMPLETED WITHIN 7 DAYS OF DISCOVERY. PREPARE AND SUBMIT A SITE MANAGEMENT PLAN <br />FOR WORKING IN SURFACE WATERS. <br />F.REMOVE TRACKED SEDIMENT FROM PAVED SURFACES BOTH ON AND OFF SITE WITHIN 24 HOURS <br />OF DISCOVERY. STREET SWEEPING MAY HAVE TO OCCUR MORE OFTEN TO MINIMIZE OFF SITE <br />IMPACTS. LIGHTLY WET THE PAVEMENT PRIOR TO SWEEPING <br />G.MAINTAIN ALL BMPS UNTIL WORK HAS BEEN COMPLETED, SITE HAS GONE UNDER FINAL <br />STABILIZATION, AND THE NOTICE OF TERMINATION (NOT) HAS BEEN SUBMITTED TO THE MPCA. <br />AREA SUMMARY <br />SPECIAL SITE NOTES <br />IF SITE REQUIRES PERMANENT STORMWATER MANAGEMENT HYDROLOGIC AND WATER QUALITY <br />MODELING DATA IS AVAILABLE UPON REQUEST. <br />THE SWPPP COORDINATOR MUST BE AVAILABLE FOR AN ONSITE INSPECTION WITHIN 72 HOURS UPON <br />REQUEST BY THE MPCA AND SHALL BE RESPONSIBLE FOR THE FOLLOWING: <br />·SUBMIT THE NPDES PERMIT APPLICATION AND COMPLY WITH ALL REQUIREMENTS <br />·IMPLEMENT THE SWPPP. <br />·OVERSEE INSTALLATION AND MAINTENANCE PRACTICES AND REPAIRS IDENTIFIED IN THE SWPPP. <br />·IMPLEMENT AND OVERSEE EMPLOYEE TRAINING AND RECORD IN OR WITH THE SWPPP. <br />·CONDUCT OR PROVIDE FOR INSPECTION AND MONITORING ACTIVITIES AND MAINTAIN LOGS AS <br />PERMIT REQUIRES. <br />·IDENTIFY OTHER POTENTIAL POLLUTANT SOURCES NOT LISTED IN THE SWPPP AND ADD THEM. <br />·IDENTIFY ANY DEFICIENCIES IN THE SWPPP AND CORRECT THEM. <br />·ENSURE THAT CHANGES TO CONSTRUCTION PLANS ARE ADDRESSED IN THE SWPPP. <br />·FILE THE NOTICE OF TERMINATION UPON PROJECT COMPLETION. <br />AFTER THE NOTICE OF TERMINATION HAS BEEN FILED, THE OWNER SHALL BE RESPONSIBLE FOR <br />ASSIGNING RESPONSIBILITY FOR PERMANENT MAINTENANCE MEASURES. <br />PERMITS <br />THE FOLLOWING PERMITS APPLY TO THIS PROJECT: <br />NOTE: IF THE 25' BUFFERS ARE MAINTAINED FORM THE WETLANDS, ADDITIONAL PERMITS WILL NOT BE <br />REQUIRED. <br />LOCATION OF SWPPP REQUIREMENTS <br />THE REQUIRED SWPPP ELEMENTS MAY BE LOCATED IN MANY PLACES <br />WITHIN THE PLAN SET. PLAN VIEW OF THE GRADING PLAN MEASURES CAN BE FOUND ON C5 - GRADING <br />PLAN <br />SWPPP AMENDMENTS <br />A QUALIFIED INDIVIDUAL MUST COMPLETE ALL SWPPP CHANGES. CHANGES INVOLVING THE USE OF A <br />LESS STRINGENT BMP MUST INCLUDE A JUSTIFICATION DESCRIBING HOW THE REPLACEMENT BMP IS <br />EFFECTIVE FOR THE SITE CHARACTERISTICS. <br />PERMITTEES MUST AMEND THE SWPPP TO INCLUDE ADDITIONAL OR MODIFIED BMPS AS NECESSARY TO <br />CORRECT PROBLEMS IDENTIFIED OF ADDRESS SITUATIONS WHENEVER THERE IS A CHANGE IN DESIGN, <br />CONSTRUCTION OPERATION, MAINTENANCE, WEATHER, OR SEASONAL CONDITIONS HAVING A <br />SIGNIFICANT EFFECT ON THE DISCHARGE OF POLLUTANTS TO SURFACE WATERS OR GROUNDWATER. <br />PERMITTEES MUST AMEND THE SWPPP TO INCLUDE ADDITIONAL OR MODIFIED BMPS AS NECESSARY TO <br />CORRECT PROBLEMS IDENTIFIED OR ADDRESS SITUATIONS WHENEVER INSPECTIONS OR <br />INVESTIGATIONS BY THE SITE OWNER OR OPERATOR, USEPA OR MPCA OFFICIALS INDICATE THE SWPPP <br />IS NOT EFFECTIVE IN ELIMINATING OR SIGNIFICANTLY MINIMIZING THE DISCHARGE OF POLLUTANTS TO <br />SURFACE WATERS OR GROUNDWATER OR THE DISCHARGES ARE CAUSING WATER QUALITY STANDARD <br />EXCEEDANCES OR THE SWPPP IS NOT CONSISTENT WITH THE OBJECTIVES OF A USEPA APPROVED TMDL. <br />ALL AREAS DISTURBED BY CONSTRUCTION W <br />SPECIFICATIONS AND WITHIN THE SPECIFIED <br />OCCUR WHEN THE SITE HAS A UNIFORM VEG <br />DISTURBED AREA COMPARED TO EXISTING C <br />PREVENTION AND SEDIMENT CONTROL BMPS <br />STORM WATER POLLUTION PREVENTION PLAN NARRATIVE - PAGE 1 OF 2 <br />1-MILE <br />RADIUS <br />AROUND <br />PROJECT <br />HARDWOOD <br />CREEK <br />ONEKA <br />LAKE <br />WATERS WITHIN 1 MILE RADIUS <br />NAME OF WATER <br />BODY <br />TYPE (LAKE, <br />RIVER, <br />WETLAND, <br />DITCH, ETC) <br />APPENDIX A <br />SPECIAL WATER <br />(YES OR NO) <br />IMPAIRED <br />WATER WITHIN 1 <br />MILE OF <br />PROJECT SITE <br />(YES OR NO) <br />APPROVED <br />TMDL <br />RECEIVING <br />WATERS <br />(YES OR NO) <br />HARDWOOD CREEK NO YES YES YES <br />CONTACT INFORMATION <br />ORGANIZATION CONTACT NAME PHONE <br />SOUTHWIND HOLDINGS LARRY ALM <br />ANDERSON ENGINEERING (SWPPP DESIGN)JARED RICHNER*763-412-4000 <br />[CONTRACTOR] <br />AGENCY TYPE OF PERMIT PERMIT # AND DATES <br />MINNESOTA POLLUTION <br />CONTROL AGENCY (MPCA) <br />NPDES CONSTRUCTION <br />PERMIT <br />CITY OF HUGO GRADING PERMIT <br />CITY OF HUGO BUILDING PERMIT <br />PROJECT <br />SITE <br />PLOTTED:COMM. NO. <br />DRAWING NO. <br />----17004 <br />ONEKA PRAIRIE <br />1 3 6 0 5 1 s t A v e n u e N . #1 0 0 <br />P l y m o u t h , M N 5 5 4 4 1 | a e -m n .c o m <br />P 7 6 3 .4 1 2 .4 0 0 0 | F 7 6 3 .4 1 2 .4 0 9 0 <br />A n d e r s o n E n g i n e e r i n g o f M i n n e s o t a , L L C <br />DRAWING TITLE <br />CHECKED BY:DRAWN:DESIGNED: <br />ATJRAT <br />08/09/2022 <br />REVISION LOG <br />DESCRIPTION OF REVISIONSNO.DATE <br />SOUTHWIND HOLDINGS, LLC <br />PRELIMINARY PLAT <br />51317 <br />ADAM THIELE, PEPRINT NAME: <br />SIGNATURE: <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR <br />REPORT WAS PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY LICENSED <br />PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE <br />OF MINNESOTA. <br />DATE:LICENSE NO.08/09/2022 <br />1 8/19/22 REVISED PER CITY COMMENTS <br />2 10/31/22 REVISED PER UPDATED DELINEATION <br />3 11/18/22 REVISED PER CITY COMMENTS <br />4 11/21/22 STORM SEWER REVISIONS <br />SWPPP - PG 1 <br />C9