Laserfiche WebLink
Sketch Plan Submittal January 12, 2026 <br />Frenchman Village Page 5 of 6 <br /> <br /> <br /> <br /> <br /> <br />JUDICIAL DITCHES <br /> <br />3 Rice Creek Watershed District Judicial Ditches cross the site. Judicial Ditch #3 Main Trunk, Judicial <br />Ditch #3 Branch 2 and Judicial Ditch #3 Branch 3. Required roadway extensions by the City <br />necessitate ditch crossings for both Fenway Avenue and Victor Path. At a minimum, large box <br />culverts will be required for each of these crossings, with the potential for a bridge structure being <br />needed for the Victor Path crossing. Judicial Ditch #3 Branch 2 will also need to be realigned in the <br />area of the City Park. The applicant has met with Rice Creek Watershed district representatives to <br />discuss this realignment. Watershed staff indicated acceptance of the proposed realignment but noted <br />a permit process that could extend from 4 to 6 months. <br /> <br />PARCEL CONSOLIDATION/EXISTING EASEMENTS <br /> <br />The development currently consists of 9 separate parcels of land. Each of these parcels has existing <br />easement encumbrances varying from one easement to several. The process to release each parcel <br />from these easements will be daunting and must be completed prior to consolidation of the parcels via <br />the platting process. <br /> <br /> <br />SITE DIMENSIONAL AND ACCESS CONSTRAINTS <br /> <br />The site is constrained by Frenchman Road to the North, and existing floodplain/Judicial Ditches to the <br />south creating a long and narrow development corridor. This is especially true for the Downtown <br />Development area, which can be as narrow as 300’ north to south. This creates a significant challenge <br />for the design and function of the Downtown area, in particular vehicular access to the <br />commercial/office/retail component. Site access from Highway 61 to the Downton Area could change <br />this dynamic but it is the applicants’ understanding that a Highway 61 access point will not be allowed. <br /> <br />Even with the site constraints noted above, the applicant believes they have met the intent of the City’s <br />downtown plan utilizing an innovative site design with the Hugo Downtown Plan in mind. <br /> <br /> <br />SOIL CORRECTIONS <br /> <br />As previously mentioned, major site grading will be required to remove portions of the development <br />site from the FEMA 100-year floodplain and create compensatory floodplain storage. In addition, <br />because of overall poor soils on the site, significant soil corrections will be needed to create stable <br />building pads and roadway sections. The full extent of required soil corrections will not be known <br />until actual site grading is taking place. <br /> <br /> <br />