Laserfiche WebLink
for future right-of-way existed between the two property exceptions along Condit Street. <br />As a result, it was anticipated that a street could someday be constructed in such <br />location. Further investigation has revealed that no such easement exists. In <br />consideration of this matter, the City may not wish to condemn private property to <br />provide such a connection or create an associated building setback non-conformity. <br />Regardless of whether or not an additional Condit Street connection is provided, the <br />proposed connection of the two dead-end streets is considered positive. At over 900 <br />feet in length, Yorkton Ridge significantly exceeds the City's maximum cul-de-sac length <br />requirement of 500 feet. Also at approximately 900 feet in length, Burke Lane exceeds <br />the maximum requirement. Thus the proposed street connection will both improve area <br />public safety, emergency response, and traffic flow and eliminate two non-conforming <br />conditions. <br />Lots. The plat consists of eleven lots and one outlot. Generally speaking, the <br />proposed lot configuration is considered acceptable. All lots have been found to meet <br />or exceed minimum lot area and width requirements (10,000 square feet and 75 feet) of <br />the R-1 zoning district. <br />One issue that should receive additional attention is in regard to the proposed lot layout <br />for Lot 1, Block 1. As illustrated, the lot includes a stormwater holding pond in an <br />easement. Including the pond, the lot is more than 30,000 square feet in area. While <br />ample upland area exists within the lot to accommodate home construction, question <br />exists as to whether or not the ponding area should be established as an outlot. This <br />issue should be subject to comment and recommendation by the City Engineer. <br />Trip Generation. The City has received several questions concerns about the traffic <br />related impacts of the proposed subdivision. According to the Institute of Transportation <br />Engineers (ITE) Trip Generation Manual, a single family dwelling averages 10 vehicle <br />trip ends per day. During the peak hours of traffic, the ITE data estimates that <br />approximately .75 trips per unit per hour will be generated in the morning, and 1.0 trips <br />per unit per hour in the evening. This means that for an 11 unit subdivision, the peak <br />morning hour will experience 8 additional vehicles, and there would be 11 additional <br />vehicles in the peak evening hour. Essentially, this would result in just one additional <br />car per every 5 to 7 minutes. In addition, this traffic would be expected to be split <br />between Burke Lane and Yorkton Ridge. As a result, the additional street traffic during <br />the busiest periods would be one car per 10 to 15 minutes. Volumes during other times <br />of the day would be even less. <br />Setbacks. While it appears that all proposed lots have an ability to meet applicable <br />setback requirements, such setbacks should be illustrated on the preliminary plat. <br />Grading Drainage and Utilities. While the preliminary plat illustrates a conceptual <br />utility plan, a specific grading and drainage plan has not been submitted. Thus, a <br />grading, drainage and utility plan should be submitted for review. <br />