My WebLink
|
Help
|
About
|
Sign Out
Home
Search
06/08/2016 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2016
>
06/08/2016 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2022 3:33:59 PM
Creation date
6/7/2016 2:01:38 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
06/08/2016
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Katie Larsen <br />June 2, 2016 <br />Page 2 <br />ENVIRONMENTAL <br />1. No additional comments with the revised submittal. <br />WATER SYSTEM <br />Install an additional 16" gate valve at the intersection of Cypress St and the south end of <br />Rosewood St. <br />2. Add temporary hydrants to the dead end stubs at the south end of Cypress St and the west <br />end of the north leg of Rosewood St. <br />3. The hydrant at the intersection of Rosewood and Cypress Street should be located just <br />south of the lift station. <br />4. Add note that all watermain including valves, fittings, hydrants, and appurtenances is to <br />be wrapped in polyethylene film. <br />5. Add note that all fittings shall be ductile iron Class 350 compact fusion -bonded epoxy <br />coated. <br />6. Show horizontal separation on plans between sanitary sewer and watermain as 10' min. <br />instead of 10' typ. <br />SANITARY SEWER SYSTEM <br />1. Add street stationing to the utility profile of all sheets, consistent with the street plans. <br />2. Show the installation of tracer wire for all sanitary services. Provide access to wire ends <br />for future locating requirements. <br />3. Sanitary sewer deeper than 15 feet shall be SDR 26. <br />4. The lift station is to serve the Northpointe development and additional area to the west <br />and south per the City's Comprehensive Plan. <br />4. The lift station shall be designed to pump a minimum of 250 gpm and have an operating <br />capacity (volume between floats) of 190 gallons. The on/off floats should be set between <br />6 and 12 inches apart. The applicant shall submit a design for review including site <br />grading, access, electrical and civil. <br />STORM SEWER SYSTEM <br />1. Provide storm sewer calculations and drainage area maps to verify the size of pipes and <br />spacing of catch basins. <br />S:\CommwityDevelopmmt\Projeas\Plnning Cases\NorthPointe\4th Addition -Final Plat\Staff Repoes\20160608 PZ\2 20160602 Engineering Review Northpoi <br />
The URL can be used to link to this page
Your browser does not support the video tag.