4 <br /> <br />Architectural Plans and Exterior Building Materials <br /> <br />The existing exterior materials consist of CMU, brick, EFIS, glass, metal flashing and an <br />awning. The building façade has recognizable elements of a base, middle and top, with various <br />building materials and complementary colors. Materials and colors are compliant with the Lino <br />Lakes Marketplace PDO Design Guidelines. <br /> <br />The existing building height is 16’0-16’8” to the rooftop, 18’8” to the parapet and 22’4” to the <br />cornice. <br /> <br />The proposed restaurant includes ground mounted mechanical equipment with 6 ft cedar, stained <br />fence screening and exterior stair structure. The rooftop includes dining/bar areas, restrooms, <br />stone fire pits, elevator shaft, metal guardrails and mechanical equipment with 6 ft cedar, stained <br />fence screening. Exterior materials include glass, stucco and metal parapet cap flashing to match <br />existing. These materials are compliant with the Lino Lakes Marketplace PDO Design <br />Guidelines. <br /> <br />The proposed building height is 17’6” to the rooftop, 29’6” to bar and restroom parapet and <br />33’2” to elevator shaft parapet. These improvements increase the height of the building in some <br />areas by 11 feet. <br /> <br />West (Rear) Elevation <br /> <br />Ground mounted mechanical equipment is proposed along the west (rear) elevation of the <br />building. Equipment consists of cooler freezer condensers, makeup air, dishwasher exhaust and <br />hood exhaust. The equipment is shown on the plan sheets as dashed lines behind the screen <br />fences. Per Sheet A1.1, Site Plan, the applicant proposes to install four (4) sections of a 6 ft high <br />stained cedar screen fence adjacent to the rear sidewalk and trash enclosure driveway to screen <br />the equipment. Shrubs are also proposed along the fence. The plan sheet notes that gaps between <br />the fence boards may occur when not using tongue and groove system. The 6 ft tall fence does <br />not completely screen the 9 ft tall exhaust unit. <br /> <br />Staff Comments <br /> <br />1. Screen fencing may not block egress paths. <br />2. Sheet A6.1 under Exterior Elevation Keynote the last #23 shall be revised to #25. <br />3. Is the proposed 6 ft high stained cedar fence (non-tongue and groove) acceptable? <br />4. The screen fence shall be high enough to screen the exhaust unit. <br />5. Should fencing be installed south of the hood exhaust to provide additional screening? <br />6. Restroom exhaust location and details shall be shown. <br />7. Dishwasher exhaust location shall be clearly shown. Is it above or into the trash <br />enclosure? <br />8. Details are required for proposed rooftop fence screening. <br />9. Is red an acceptable color for the rooftop safety railings? <br /> <br />