My WebLink
|
Help
|
About
|
Sign Out
Home
Search
11/10/2004 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2004
>
11/10/2004 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2014 2:27:11 PM
Creation date
6/17/2014 12:20:14 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
11/10/2004
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TKDA <br />• ENGINEERS • ARCHITECTS • PLANNERS <br />MEMORANDUM <br />To: James E. Studenski <br />Copies To: Pat Windier <br />From: <br />Date: <br />Stephen W. Hartley <br />November 4, 2004 <br />Document Reviewed: <br />HydroCAD model dated October 4, 2004 <br />Grading Plan undated <br />Comments: <br />1500 Piper Jaffray Plaza <br />444 Cedar Street <br />Saint Paul, MN 55101 -2140 <br />(651) 292 -4400 <br />(651) 292-0083 Fax <br />www.tkda.com <br />Reference: New Brighton Kingdom Hall <br />Drainage Review <br />Lino Lakes, Minnesota <br />Comm. No. 12976.002 <br />Routing: <br />• 1. The minimum pipe outlet size is 15" RC pipe, the HydroCAD model shows a 12" RC pipe. <br />2. An infiltration rate of 0.0083 ft/min corresponds to an infiltration rate of 5.98 in/hr. Rice Creek <br />Watershed District's design standard for NRCS type "A" soils is 0.50 in/hr, unless a percolation test has <br />been preformed. If so, supporting documentation is needed. <br />3. When existing condition soil type are NRCS type "A" soils, NRCS type "B" soils need to be used in <br />disturbed areas under proposed conditions. <br />4. A drainage area map needs to be submitted for both existing and proposed conditions. <br />5. The submitted computations, according the HydroCAD header, is for developed conditions. Please <br />submit the existing condition computations. <br />6. A differentiation is needed between existing and proposed contours on the grading plan. <br />7. The location of the proposed pond outlet is needed on the grading plan. <br />8. Approval from Rice Creek Watershed District is needed. <br />An Employee Owned Company Promoting Affirmative Action and Equal Opportunity <br />
The URL can be used to link to this page
Your browser does not support the video tag.