My WebLink
|
Help
|
About
|
Sign Out
Home
Search
01-25-2016 Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
1982-2020
>
2016
>
01-25-2016 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2016 1:39:20 PM
Creation date
2/23/2016 3:48:13 PM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
01/25/2016
Council Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.04 References: <br />A. Materials used in this section shall be listed in the latest editions of the following: <br />1. Factory Mutual Approval Guide. <br />2. The NRCA Roofing and Waterproofing Manual, 5th Edition — National <br />Roofing Contractors Association <br />3. The current edition of the Architectural Sheet Metal Manual as published <br />by the Sheet Metal and Air Conditioning Contractors National <br />Association, Inc., (SMACNA) shall govern where applicable, unless <br />otherwise specified. <br />4. Low slope membrane roof metal edge securement except gutters shall be <br />tested for wind resistance in accordance with ANSI/SPRI ES -1. <br />1.05 Submittals: <br />A. General: Comply with the provisions of Section 01 33 00 Submittal Procedures <br />and 01 32 16 Construction Progress Schedules. <br />B. Shop Drawings: If requested by the Architect/Engineer, prepare and submit shop <br />drawings of proposed material for architect's/engineer's review, including full- <br />size drawings of all profiles and details of all connections, expansion joints, <br />reinforcement, anchors and other pertinent features. <br />C. Product data: If requested by the Architect/Engineer, submit manufacturer's <br />product data on all pre -fabricated metal roof flashing sections, complete with all <br />pertinent information, finishes and installation instructions. <br />D. Samples: In lieu of shop drawings above, Contractor may submit full-size samples <br />in duplicate of all required profiles and details. <br />E. As part of the contractor's construction submission package, contractor shall <br />submit the following for Architect/Engineer review. The Contractor shall submit <br />the below information to the building department if requested: <br />1. Product data, including ASTM D2137 & D573 results. <br />2. Manufacturer recommended installation torque. <br />3. Contractor's quality control and assurance program. <br />4. Certification letter from Contractor. <br />1.06 Product Handling: <br />A. Delivery and storage: Deliver materials to the job site in original, unopened <br />containers no sooner than five (5) calendar days prior to start of job. Materials to <br />be stored up, off of the roof deck or ground, and covered with a weatherproof <br />covering anchored sufficiently so as to resist wind blow -off. Only those materials <br />necessary to accomplish two days' work are to be stored on the roof. <br />1. Contractor is responsible for all materials delivered to job site until <br />completion of project. <br />2. When storing materials on the roof, do not overload deck. <br />Flashing and Sheet Metal <br />07 62 00-2 <br />City of Lino Lakes <br />Lino Lakes Fire Station #1 <br />RSI Project # 15-12120-02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.