My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
#25 - Birdgewater Village Preliminary Plat
LakeElmo
>
City Council
>
City Council Meeting Packets
>
2020's
>
2024
>
02-06-24
>
#25 - Birdgewater Village Preliminary Plat
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 4:38:50 PM
Creation date
3/19/2024 10:07:10 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PAGE 2 of 5 <br />4. Stillwater Way Right‐of‐way. The Preliminary Plat/Plans show the subdivision acquiring 30‐feet of public <br />right‐of‐way from the City along most of Stillwater Way. Following the Plat recording, Stillwater Way will <br />retain a consistent 45‐foot right‐of‐way along the Plat boundary, as measured from the existing <br />centerline. Staff review has determined that the 45‐foot right‐of‐way is adequate. <br />5. Stillwater Lane Access. Site Plans must be prepared that clearly label and dimension the proposed access <br />spacing along Stillwater Lane. Linora Avenue appears to be spaced 400 feet from Little Bluestem Trail as <br />required. The secondary access at Linden Avenue will need to be revised to maintain a minimum 330 ft. <br />access spacing in accordance with previous plan review comments. The Preliminary Plat and Plans must all <br />be revised accordingly. <br />6. Revise the Preliminary Plat/Plans to call out Outlots A, B and C to be HOA owned. This includes the HOA <br />providing ongoing ownership and maintenance of the stormwater management BMPs and storm water <br />reuse irrigation system. <br />7. Revise the Preliminary Plat and Plans to provide a 10‐foot drainage and utility easement along the public <br />right‐of‐way of Stillwater Boulevard (CSAH 14) and Manning Avenue (CSAH 15) for Outlot C, Lot 1, Lot 2 <br />and Lot 3. These dedicated easements must be shown on all site, grading, utility, and landscape plans <br />consistent with the Preliminary Plat, and remain free from encroachments, including storm sewer pipes, <br />retaining walls, and trees. Where existing easements are present, the 10‐ft. corridors must be shown and <br />preserved within the existing easements for small/dry utility installation. <br />8. G‐005. Label each Typical Section as Linora Avenue North. Revise boulevard grade as 4% max. <br />9. G‐006. Label non turn lane Typical Section as Upper 40th Street North and Linden Avenue North. Label <br />turn lane Typical Section as Linden Avenue North. Revise boulevard grade as 4% max. <br />10. G‐007 to G‐013. Revise Linora Avenue North to include the required right turn lane at Stillwater Lane per <br />the proposed typical section. <br />11. G‐007 to G‐013. Revise the northern two driveway accesses along Linora Avenue to be clear of the <br />required right turn lane. Maintain driveway access alignment with each other and revise to intersect <br />Linora Avenue at 90‐degrees. <br />12. G‐007 to G‐013. Revise driveway access spacing between Lot 3 and Lot 4 to be minimum 100‐ft. <br />separation (from CL to CL). <br />13. G‐007 Master Plan. Revise plan sheet to clearly identify the proposed Preliminary Plat/Site Plans included <br />with the application for City review, and clearly identify future non application ghost platting. <br />14. Revise site plans to remove the temporary cul‐de‐sac and extend Linden Avenue to connect to Stillwater <br />Way. <br /> <br />GRADING PLANS, STORMWATER MANAGEMENT AND STORM SEWER SYSTEM <br />1. The subdivision is subject to a storm water management plan meeting State, Valley Branch Watershed <br />District (VBWD) and city rules. A VBWD permit is required. Storm water facilities proposed as part of the <br />development to meet State and watershed permitting requirements must be constructed in accordance <br />with the City Engineering Design Standards Manual dated January 2022. <br />2. The storm water management plan is required to be certified by a registered professional engineer. The <br />SWMP must be revised accordingly and resubmitted. <br />3. The SWMP indicates that the site is assumed to be 75% impervious in the post development condition. <br />The SWMP must be revised to include a table showing each proposed Lot in the subdivision and the <br />corresponding impervious surface allowance for each Lot. <br />4. The storm water plan proposes stormwater reuse irrigation and infiltration to meet volume control <br />permit requirements. City design standards require that flood management provisions be implemented <br />for all new developments assuming no storm water reuse irrigation is operating. The SWMP must be <br />revised to verify this design criteria. <br />5. All storm water basins have been placed in Outlots as required. Each Outlot must fully incorporate the <br />100‐year HWL, 10‐foot maintenance bench and all maintenance access roads. Maintenance access roads <br />meeting city standards must be provided for all storm water facilities and structures.
The URL can be used to link to this page
Your browser does not support the video tag.