- 7 - <br /> 23. Soldered Gas Lines: Illegal and not acceptable. Must be corrected to <br /> code. <br /> Flex Line: The commonly-found pleated copper lines or flex-lines are <br /> not approved. They must be replaced using solid iron pipe or soft- <br /> copper tubing with flared fittings. At the present time no flexible <br /> connectors of any kind have been approved by the State of Minnesota for <br /> residential use. <br /> Condition of Gas Valves: These are emergency shut-off devices for any <br /> gas appliances such as the gas range, spaceheater and dryer. They must <br /> be easily operated without the use of a tool . Sticking valves cannot be <br /> accepted nor can they be loosened if they have a hex nut (because this <br /> will cause leakage) . If new valves are required, they must be UL or <br /> AGA-approved or ball valves. All must be in an easily accessible <br /> location. No valve can control more than one appliance and all gas <br /> appliances must have an operable shut off valve. <br /> 24. Flues: Must be in good condition. Excessive corrosion or weakness is <br /> not acceptable. All joints must be secured with metal screws. <br /> Flues (Class "A") for Woodstoves and Solid-fuel Appliances: These need <br /> to be installed as part of an overall accepted heating system package. <br /> They must be approved and listed and must be installed as per <br /> manufacturer's specifications. Unlisted items must be removed or <br /> modified to meet proper clearances to combustibles. <br /> Diverters: Where required and existing on a flue, they must be in good <br /> .operating condition (no deterioration) . <br /> Clearances: Clearances to combustibles or insulation must be met in all <br /> types of flues. A class "C" flue (single metal wall) requires a minimum <br /> of 6 inches to combustibles (e.g. wood framing and/or paneling in a <br /> basement partition wall) . A class "B" flue (double wall ) requires a <br /> minimum of 1 inch to combustibles. <br /> NOTE: If the requirements for class "C" cannot be met without major <br /> remodeling, sometimes the replacement of the "C" flue with a "B" flue <br /> (needing 1 inch clearance) will solve the problem. An approved <br /> chaseway must be supplied for all flues. where they go through any living <br /> or storage area (e.g. main floor closet) to maintain a proper clearance <br /> to combustibles. <br /> 25. Masonry Chimney Condition: Must be in satisfactory condition. All <br /> holes need to be permanently sealed with concrete. If appliance flues <br /> enter chimney, they must be mortared in. Where there is a metal lining <br /> in a chimney, a drip-T moisture-escape tube must be at bottom. <br /> Fireplaces: Must be in good condition. All gaps and loose bricks must <br /> be mortared with fire-resistive mortar. Dampers must be operable. The <br /> condition and installation of the firebox can be of a surface visual <br /> inspection only and cannot guarantee that it was correctly installed <br /> initially. No fireplace can be installed unless directly integral with <br /> chimney (no intervening flue) and cannot share liner with any appliance. <br /> Combustible material shall not be placed within 6 inches of the <br /> fireplace opening. <br />
The URL can be used to link to this page
Your browser does not support the video tag.