Western Spring Site Plan <br />Page 5 <br />Trails <br />There is a City trail on the west side of Fenway Boulevard North. The applicant is not proposing <br />any sidewalks or trails with this development. <br />Building Architecture <br />The building material for the Western Spring facility consists of precast tip -up concrete panels. <br />The intent is to ensure the building is constructed of quality materials that require minimum <br />maintenance. The applicant has provided elevations that show colorations that include buffs, <br />tans, browns, and reds. The concrete panels are proposed to have an aggregate panel texture. <br />These elements, the addition of windows on all elevations, and the use of awnings on the north <br />elevation, visually break up the massing of the building walls. <br />It is in staff's opinion that the proposed building is well designed and appealing and meets the <br />Commercial and Industrial Design Guidelines. <br />Signage <br />The applicant is proposing a sign on the west elevation of the building. Staff has discussed with <br />the applicant that a sign permit application will be required before the installation of any sign on <br />the property or building. It has been added as a condition that a sign permit application will be <br />required to be reviewed and approved by City staff prior to any sign installation. <br />DrainagelGrading <br />The property is within the drainage area of the Bald Eagle Industrial Park Pond project <br />completed when the Industrial Park was developed. As a result, a portion of the stormwater <br />storage and treatment requirements are met. The rules of Rice Creek Watershed District for <br />Stormwater Management (in addition to City requirements) apply to the site. The applicant has <br />proposed an infiltration basin and a pretreatment basin to address these requirements. The basin <br />has been sized to accommodate the proposed building, and all parking areas, including the proof <br />of parking. The infiltration basin would hold and additional 0.9 acres that may be used with <br />future building expansion. City staff will continue to work with the applicant to address <br />technical design and other minor issues, which generally will not affect the site plan, as the <br />project moves forward. <br />The City stormwater trunk fee will apply to these parcels, and will be calculated and collected at <br />the time of building permit. <br />The applicant has proposed an outlet located on the southern property line. This outlet is <br />proposed to collected drainage from the proposed site as well as a site the applicant owns along <br />130th Street North. Because of this, staff has required the applicant to draft and execute a <br />stormwater drainage and maintenance agreement between the two parcels, which will be added <br />as a condition of approval. <br />