My WebLink
|
Help
|
About
|
Sign Out
Home
2017.12.20 Parks Packet
Hugo
>
Community Development
>
Parks
>
Parks Commission
>
Parks Commission Agenda/Packets
>
2017
>
2017.12.20 Parks Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/2/2019 12:00:47 PM
Creation date
10/2/2019 11:04:01 AM
Metadata
Fields
Template:
Commissions
Meeting Date
12/20/2017
Document Type
Agenda/Packets
Commission Name
Parks
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Image Placeholder <br />ACOMPREHENSIVE SANITARY <br />SEWER PLAN <br />2040 COMPREHENSIVE PLAN UPDATE DRAFT Dec14-17 <br />for review only <br />Table 11-4 Existing Sanitary Sewer System Flows <br />Sewer Sub- <br />District <br />Adjusted <br />Average Flow <br />(MGD) <br />MCES <br />Design Peak <br />Flow Factor <br />Design Peak <br />Flow (MGD) <br />A1 0�0008 4�0 0�0033 <br />B1 0�0007 4�0 0�0029 <br />B2 0�0008 4�0 0�0034 <br />C1 0�0026 4�0 0�0103 <br />C2 0�0028 4�0 0�0111 <br />D2 0�0083 4�0 0�0331 <br />E1 0�0057 4�0 0�0229 <br />E2 0�0133 4�0 0�0531 <br />E3 0�0226 4�0 0�0904 <br />E5 0�0099 4�0 0�0395 <br />F1 0�0058 4�0 0�0230 <br />G2 0�0202 4�0 0�0806 <br />H1 0�0030 4�0 0�0121 <br />H2 0�0072 4�0 0�0288 <br />I1 0�0210 4�0 0�0840 <br />I2 0�0024 4�0 0�0096 <br />I3 0�0063 4�0 0�0251 <br />I4 0�0617 4�0 0�2466 <br />J1 0�0169 4�0 0�0676 <br />J2 0�0104 4�0 0�0415 <br />Existing System Analysis and <br />Deficiencies <br />The existing sanitary sewer system capacities to convey existing <br />system wastewater flows to the MCES collection system were <br />analyzed by considering the land use designations within the Sewer <br />Districts shown in Map 11-2 and typical MCES flow assumptions per <br />capita� Existing system as-built information was used to determine <br />pipe capacities. Average day flows were calculated by determining <br />the acreages of each land use designation in each district, assuming a <br />typical flow generated per capita, and scaling the flows to coincide with <br />MCES flow data. <br />All trunk sanitary sewer mains exhibited adequate capacity for the <br />existing system flows. Table 11-4 summarizes the existing average <br />and peak system flows by Sewer Sub-District. The flows reported <br />below do not include flow from upstream Sub-Districts. However, <br />cumulative flows from upstream Sub-Districts were considered in the <br />capacity analysis of existing trunk sewer and lift stations� <br />As detailed in the following table, all of the City’s existing lift stations <br />have sufficient capacity to accommodate additional growth. Table <br />10-5 shows existing lift station pump capacity and existing peak flow <br />information� <br />Sewer Sub- <br />District <br />Adjusted <br />Average Flow <br />(MGD) <br />MCES <br />Design Peak <br />Flow Factor <br />Design Peak <br />Flow (MGD) <br />J3 0�0053 4�0 0�0213 <br />J4 0�0125 4�0 0�0500 <br />J5 0�0204 4�0 0�0817 <br />K1 0�0715 4�0 0�2860 <br />K2 0�0249 4�0 0�0996 <br />K3 0�0074 4�0 0�0295 <br />K4 0�0301 4�0 0�1204 <br />K5 0�0161 4�0 0�0643 <br />L1 0�0134 4�0 0�0534 <br />L2 0�0104 4�0 0�0416 <br />L3 0�0071 4�0 0�0286 <br />M1 0�0433 4�0 0�1731 <br />N2 0�0184 4�0 0�0735 <br />N3 0�0083 4�0 0�0331 <br />N4 0�0389 4�0 0�1554 <br />N5 0�0194 4�0 0�0777 <br />N6 0�0225 4�0 0�0902 <br />N9 0�0250 4�0 0�1001 <br />Total Existing <br />System Flows <br />0617 34 2098
The URL can be used to link to this page
Your browser does not support the video tag.